BrandThermo Fisher
OriginGlobal Manufacturing (Non-China)
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument CategoryOrbital Roller Mixer
ModelThermo Scientific Roller Mixer
Pricing RangeUSD 1,400 – 2,800 (FOB)
Timer Range0–999 min or Continuous Operation
Rotational Speed1–80 rpm
Temperature Control Range4 °C to 60 °C
Platform ConfigurationSingle-roll axis, dual-tier stackable design
ComplianceCE, ISO 9001 certified manufacturing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelA214, A324
Instrument TypeMulti-Ion Analyzer
Measurement ModulespH/Temp, pH/ISE/Temp, pH/LogR/Temp, Conductivity/Temp, DO/Temp
Data Storage2000–5000 entries (GLP-compliant)
DisplayFull-color LCD with multi-parameter overlay
ConnectivityDual USB + RS232
Protection RatingIP54 (benchtop), IP67 (portable A329)
Power OptionsAC adapter (90–260 V AC) or 4×AA batteries
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelBiosystem (Single-Position, Controller Not Included) / Biosystem 4-Position (Controller Not Included)
Stirring Capacity20 L (single position) / 5 L per position (4-position)
Speed Range5–120 rpm
Temperature Operating Range–10 °C to +56 °C (at 100% relative humidity)
Controller RequirementExternal Biomodul 40B controller (one unit supports up to two Biosystem units)
ConstructionSeamless stainless-steel housing, CO₂ incubator-compatible design
Power RegulationIndependent power adjustment per stir position
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelMaxQ 416HP / MaxQ 430HP
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Instrument TypePortable
Measurement PrincipleAmperometric Electrochemical Sensor
Measurable ParametersFree Chlorine, Total Chlorine, pH, Chlorine Dioxide, Cyanuric Acid
Free Chlorine Range0.02–4.0 mg/L (US EPA Validated Range: 0.03–2.0 mg/L)
Total Chlorine Range0.02–4.0 mg/L (US EPA Validated Range: 0.03–2.0 mg/L)
Chlorine Dioxide Range0–9 mg/L
pH Range5.9–8.2
Cyanuric Acid Range5–90 mg/L
Sample Volume10 mL
DisplayLCD
Power4×AAA batteries (≥3000 measurements, auto-off)
Ingress ProtectionIP67
Operating Environment0–50 °C, 0–90% RH (non-condensing at 30 °C)
ComplianceCE, TÜV, FCC Part 15
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeTube Furnace
Max Temperature1100°C
Temperature Control Accuracy±2–4°C
Max Power3300 W
Ramp Rate (to Max Temp)6–12°C/min
Heating MethodResistive Wire Heating
Internal Chamber Dimensions152.4 × 304.8 × 152.4 mm
ControllerMicroprocessor-Based PID with Multi-Stage Ramp/Soak Programming
Thermocouple TypeK-Type
Optional InterfaceRS485 Digital Communication Port
InsulationMoldatherm™ High-Efficiency Ceramic Fiber with Hollow-Core Air Gap Design
Zone ConfigurationIndependent Three-Zone Heating & Control
Safety FeaturesAdjustable Over-Temperature Cut-Off, Dual-Redundant Thermal Protection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginImported
ManufacturerThermo Fisher Scientific
ModelMicroPure
Purified Water GradeType I (ASTM D1193-20)
Resistivity18.2 MΩ·cm @ 25°C
Total Organic Carbon (TOC)1–5 ppb
Endotoxin< 0.001 EU/mL
Particles (>0.1 µm)< 1 particle/mL
Flow Rate≤ 1 L/min
Dimensions (W×D×H)305 × 300 × 455 mm (without tank)
Power Consumption0.06 kW
Feed Water RequirementRO/DI/distilled water with conductivity < 5 µS/cm, TOC ≤ 50 ppb, bacteria < 100 CFU/mL, turbidity < 1.0 NTU, temperature 2–35°C, pressure 0.1–6 bar
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported Instrument
ModelD10P-48
PriceUpon Request
Electrode9648BNWP Cd²⁺ Composite Electrode
Cd²⁺ Measurement Range0.01–11,200 ppm
pH Range2–12
Temp. Range (Continuous)0–80°C
Temp. Range (Intermittent)80–100°C
Reproducibility±4%
Electrode Dimensions110 mm (L) × 13 mm (body Ø) × 16 mm (cap Ø)
Cable Length1 m
Ion Concentration Resolution1–3 significant digits
Relative Accuracy±0.1 mV or ±0.05% (whichever is greater)
pH Range−2.000 to 19.999
pH Accuracy±0.001
ORP Range±1999.9 mV
Temp. Accuracy±0.1°C
Data Storage1000 entries with timestamp
GLP ComplianceYes
CommunicationRS232 (bidirectional), optional USB
Enclosure RatingIP54
CertificationsCE, CSA, UL, TÜV, FCC Class A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelYC-288L
Temperature Range≤ –60 °C
Effective Storage Volume288 L
Interior Dimensions (W×D×H)1050 × 575 × 525 mm
Exterior Dimensions (W×D×H)1616 × 651 × 605 mm
Power Supply220 V / 50 Hz
Rated Power Consumption400 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginSingapore
ManufacturerOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelExpert pH
Instrument TypePen-style
Parameter TypeSingle-parameter (pH)
Measurement Accuracy±0.1 pH
pH Range0.0–14.0 pH
Resolution0.1 pH
Calibration StandardNIST-traceable buffer solutions
Temperature Range0.0–50.0 °C
Temp. Resolution0.1 °C
Temp. Accuracy±0.5 °C + 1 LSD
Calibration Points1–3-point auto-recognized
ATCYes
IP RatingIP67
Auto-off8.5 min idle
Power4 × A76/LR44 batteries
Operating Temp.5–45 °C
Dimensions170 × 45 × 30 mm (L×W×H)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported
ModelsSWB27 / SWB15 / SWB15S / DUB15
Instrument CategoryWater Bath / Oil Bath Constant-Temperature Tank
CirculationInternal Recirculation
Temperature ControlHeating-Only
Bath Capacity15 L / 27 L
Temperature Range+5 °C to 100 °C
Temperature Stability±0.1 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeBox Furnace
Max Temperature1200°C
Temperature Uniformity±5°C at 1200°C
Control Accuracy±2–4°C
Max Power4600 W
Ramp Rate to Max Temp6–12°C/min
Heating MethodResistance Wire (NiCr or Inconel)
Internal Dimensions (H×D×W)133.4×355.6×190.5 mm
Chamber Volume9 L
External Dimensions (H×D×W)622.3×508×508 mm
Net Weight66 kg
Thermocouple TypePlatinel II (10 ft lead with plug)
InsulationMoldatherm® ceramic fiber
Door DesignBottom-hinged, spring-assisted, floating-pin seal with high-temp insulation and viewing window
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported Instrument
Model3-Star
PriceUpon Request
pH Range-2.000 to 19.999
pH Resolution0.1 / 0.01 / 0.001
pH Accuracy±0.001
Calibration Points1–5-point with US/NIST, DIN, or Custom Buffers
ORP Range±1999.9 mV
ORP Resolution0.1 mV
ORP Accuracy±0.1 mV or ±0.05% (whichever is greater)
Temperature Range-5 to 105 °C
Temperature Resolution0.1 °C (-5 to 99.9 °C), 1.0 °C (>99.9 °C)
Temperature Accuracy±0.1 °C
Temperature CompensationAutomatic or Manual
DisplayBacklit LCD
Electrode InterfacepH – BNC
CommunicationBidirectional RS232, optional USB cable
Data Logging1000 readings
Calibration HistoryLast 10 calibrations
Method Storage10 user-defined methods
Password Protection10 user accounts
Power4×AA batteries
CertificationsCE, CSA, UL, TÜV, FCC Class A
Operating Environment5–45 °C, 5–85% RH (non-condensing)
IP RatingBenchtop – IP54
Dimensions (Benchtop)9.4 × 17.0 × 22.4 cm (H×W×L)
Dimensions (Portable)4.8 × 9.7 × 21.3 cm (H×W×L)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported
ModelS7 / S13 / S21 / S45 / S49
Temperature Range+13 °C to +300 °C
Temperature Stability±0.01 °C
Bath Volume4–53 L
Circulation TypeInternal & External
CertificationsCE / RoHS / WEEE
Added to wishlistRemoved from wishlist 0
Add to compare
OriginSingapore
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelEutech Ion2700
Instrument TypeMulti-Ion Analyzer
pH Range–2.000 to 20.000
pH Resolution0.1 / 0.01 / 0.001
pH Accuracy±0.002 pH + 1 LSD
pH Calibration PointsUp to 6
Buffer StandardsUSA, NIST, DIN, User 1, User 2, Custom
Ion Concentration Range0.001–19999 ppm (±2000.0 mV)
Ion Resolution2- or 3-digit
Ion Accuracy±0.5% of full scale (monovalent), ±1.0% of full scale (divalent)
Ion Calibration Points2–8
Temperature Range0.0–100.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.3 °C
ORP/mV Range±2000.0 mV
mV Resolution0.1 mV
mV Accuracy±0.2 mV
Temperature CompensationAutomatic or Manual (0–100 °C, pH only)
GLP ComplianceYes
Slope/Offset DisplayYes
Data Storage500 records with timestamp
DisplayBacklit LCD (5.9 × 7.8 cm)
Input InterfacesBNC (pH/ORP/ion), Phono (ATC probe), Phono (reference electrode), DC socket
Output InterfaceRS232C
Power Supply9 V DC regulated adapter (100–240 VAC SMPS, 1.3 A)
Operating Temperature5–45 °C
Dimensions (H×W×D)17.5 × 15.5 × 6.9 cm
Weight (unit)650 g
Packaging Dimensions30.8 × 23.5 × 12.4 cm
Shipping Weight1800 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginCanada
ManufacturerThermo Fisher Scientific
Product TypeImported
ModelCytomat 10C
Temperature Range & Accuracy+4 to 50 °C, ±0.1 °C setpoint stability
Temperature Uniformity±0.2 °C across chamber volume
Humidity ControlUp to 98% rH, Hydra-Smart active humidification with sterile water reservoir and particulate filtration
Capacity210 microplate positions (standard 96-/384-well format)
DecontaminationFully automated ContraCon dry-heat decontamination cycle (180 °C, validated for low-bioburden heat-resistant microorganisms)
Optional ConfigurationCopper-lined interior for enhanced antimicrobial surface performance
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product LineOrion Star LogR Series
ModelLogR
Measurement PrinciplePotentiometric pH with integrated LogR temperature sensing via pH electrode membrane resistance
pH Range–2.000 to 19.999
Resolution0.001 pH (selectable)
Accuracy±0.002 pH
Calibration Points1–5-point, auto-buffer recognition (USA/NIST, EURO/DIN)
mV Range±1999.9 mV
mV Accuracy±0.2 mV or ±0.05% of reading, whichever is greater
Temperature Range0–100 °C (manual or LogR-compensated)
LogR Temp Accuracy±0.1 °C (10–100 °C)
Resistance Range0–6000 MΩ
Resistance Resolution0.1 MΩ (<2000 MΩ), 1 MΩ (≥2000 MΩ)
Data Storage1000 readings with timestamp
InterfaceRS232
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Supplier TypeAuthorized Distributor
Origin CategoryImported
ModelFH10, FH15, FH30
Flow Rate0.0002–105 mL/min
Speed Range1.2–300 RPM
ReversibleYes
Integrated Flow SensorYes
Compatible with Dispensing ArmsYes
Input Voltage90–130 V AC or 160–260 V AC (auto-sensing, 50/60 Hz)
Motor TypePermanent Magnet DC (PMDC)
Control InterfaceManual Knob, 0–5 V / 0–10 V Analog, RS-485 Digital (Modbus RTU)
Operating Temperature0–40 °C
Storage Temperature−25–65 °C
Enclosure MaterialPowder-Coated Steel
CertificationsUL 61010-1, cULus, CE (EMC & LVD), RoHS Compliant
Dimensions (L×W×H)17.8 × 13.4 × 11.4 cm
Weight1.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginSingapore
ManufacturerThermo Fisher Scientific
Product TypeImported
ModelA221
Instrument CategoryPortable
Parameter TypesMulti-parameter
pH Measurement Range-2.000 to 20.000
Resolution0.1 / 0.01 / 0.001
Accuracy±0.001
Calibration Buffer RecognitionUSA / NIST / DIN auto-identification
Temperature CompensationAutomatic (ATC) with 8-pin mini-DIN probe interface
Data StorageUp to 2000 GLP-compliant entries
ConnectivityUSB and RS232
Power4 × AA batteries or AC adapter
IP RatingIP67
Electrode InterfaceBNC + ATC port
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeDirect Manufacturer
Product CategoryImported Instrument
ModelTSX7/TSX6/TSX5/TSX4-0086V(A/D)
Form FactorUpright
Effective Storage CapacityUp to 700 × 2-inch cryoboxes
Inner Chamber Dimensions (mm)1300 × 719 × 1019
External Dimensions (mm)1981 × 960 × 1148
Power Supply230 V, 50 Hz
Rated Power Consumption400 W
Temperature Stability±1.5 °C uniformity across chamber
Recovery Time (after 30-sec door opening)≤12 min to return to −80 °C
Holdover Time (unloaded, power-off)≥339 min at ≤−50 °C
Daily Energy Consumption<9 kWh (varies by model size)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginSingapore
ManufacturerThermo Fisher Scientific
Product TypeImported Instrument
ModelC401
PriceUpon Request
Chlorine Range0–1.99 ppm / 2.0–6.0 ppm
Chlorine Resolution0.01 ppm / 0.1 ppm
Chlorine Accuracy±0.02 ppm / ±0.2 ppm
pH Range5.9–8.2
pH Resolution0.1
pH Accuracy±0.1
Cyanuric Acid Range5–90 ppm
Cyanuric Acid Resolution1 ppm
Cyanuric Acid Accuracy±4 ppm
Light SourceLED (525 nm)
CalibrationSingle-point user-selectable per test
Operating Temperature0–50 °C
Power Supply4 × 1.5 V AAA batteries
Battery Life>3000 measurements
IP RatingIP67
Dimensions (Instrument)15.5 × 6.8 × 4.6 cm
Weight (Instrument)200 g
Packaging Dimensions35.5 × 16.5 × 10.5 cm
Package Weight1170 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginImported
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeBenchtop Refrigerated Centrifuge
Model Number75009022
Capacity4 L (with TX-1000 swing-bucket rotor)
Temperature Range-9 °C to 40 °C
Max RCF4,900 × g
Max Speed5,200 rpm
ComplianceDesigned for cGMP, ISO 13485, and cleanroom environments (Class A/B/C/D)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginGermany
ManufacturerThermo Fisher Scientific
Model Numbers51030476, 51030286, 50145503, 50145517
Temperature Range & AccuracyAmbient +3°C to 55°C
Temperature Uniformity±0.5°C
Humidity Control>93% RH at 37°C
Capacity165 L (5.8 cu. ft.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported
Models8157BNUMD (Refillable), 8107BNUMD (Low-Maintenance)
pH Range0–14
pH Accuracy±0.03 pH (with ATC)
pH Precision±0.01 pH
Temperature Range0–100 °C
Temperature Accuracy±1.0 °C
Reference SystemROSS™ Double-Junction
Internal ReferenceROSS™ Liquid Junction
Isopotential PointpH 7
Fill Solution (Refillable)3 M KCl
Body MaterialEpoxy Resin
Electrode Length120 mm
Diameter12 mm
Compatible MetersOrion Star™, Aplus™, and PerpHecT® Series