Empowering Scientific Discovery

Shimadzu TOC-L CSN Used Total Organic Carbon Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Shimadzu
Origin USA
Model TOC-L CSN
Detection Range 4 µg/L to 30,000 µg/L
Detection Limit 4 µg/L
Oxidation Method 680 °C Catalytic Combustion
Sample Types Aqueous Liquids (with optional SSM-5000A for solids)
Compliance ASTM D7573, ISO 8245, USP <643>, EP 2.2.44
Software TOC-L Series Control Software (v3.x or later)
Warranty 6 months limited
Operational Age 3–4 years
Included Accessories ASI-L Auto-sampler, OCT-L 8-channel Sampler, TNM-L Total Nitrogen Module, SSM-5000A Solid Sample Module (as configured)

Overview

The Shimadzu TOC-L CSN is a high-performance, benchtop total organic carbon (TOC) analyzer engineered for precise quantification of organic carbon content in aqueous matrices using high-temperature catalytic combustion oxidation at 680 °C. This method—developed and standardized by Shimadzu—ensures complete oxidation of both labile low-molecular-weight compounds and recalcitrant, particulate, or macromolecular organic species—including humic substances, polymers, and suspended organics—without requiring acid sparging or persulfate addition. The instrument delivers a validated linear dynamic range from 4 µg/L to 30,000 µg/L, with a method detection limit (MDL) of 4 µg/L under optimized conditions, making it suitable for ultra-trace environmental monitoring, pharmaceutical water system validation (Purified Water, WFI), and regulatory compliance testing per USP , EP 2.2.44, and JP 17. Its modular architecture supports seamless integration of ancillary units—including the TNM-L total nitrogen module for simultaneous TOC/TN analysis—and the SSM-5000A solid sample combustion unit for direct analysis of soils, sludges, and filter membranes.

Key Features

  • 680 °C catalytic combustion oxidation with Pt-coated ceramic catalyst and quartz combustion tube—ensuring >99% oxidation efficiency across diverse organic structures
  • Dual-detector NDIR (non-dispersive infrared) system for CO2 quantification, delivering high signal stability and long-term baseline reproducibility
  • Integrated ASI-L autosampler with programmable vial positioning and wash cycle control for unattended operation
  • OCT-L 8-channel multiplexer enabling automated sequential analysis of up to eight sample streams without manual intervention
  • Modular expansion capability: TNM-L adds total nitrogen measurement via thermal decomposition–chemiluminescence; SSM-5000A enables direct solid-sample analysis with programmable temperature ramping and ash correction
  • Robust hardware design compliant with IEC 61000-4 electromagnetic immunity standards and UL/CSA safety certification

Sample Compatibility & Compliance

The TOC-L CSN accepts liquid samples ranging from ultrapure water (UPW) to wastewater, process streams, and cleaning validation rinse solutions. With the SSM-5000A solid sample module, it accommodates dried filters, soil homogenates, and lyophilized residues (0.1–100 mg mass range). All configurations support audit-ready data integrity per FDA 21 CFR Part 11 when operated with validated software versions (v3.3+), including electronic signatures, user access levels, and immutable audit trails. The system meets ISO/IEC 17025 requirements for accredited laboratories and aligns with ASTM D7573 (standard test method for TOC in water by high-temperature combustion), ISO 8245 (water quality—determination of organic carbon), and pharmacopeial monographs governing water quality assurance.

Software & Data Management

Control and data acquisition are managed via Shimadzu’s TOC-L Series Control Software, which provides real-time chromatogram visualization, peak integration, calibration curve generation (linear, quadratic, or multi-point weighted), and automatic QC flagging (e.g., drift, carryover, calibration failure). Raw data files (.tdf) are stored in a structured database with timestamped metadata, supporting export to CSV, PDF, or LIMS-compatible formats (ASTM E1384, ASTM E1467). Audit trail logs record all operator actions—including method edits, result overrides, and calibration events—with tamper-evident hashing. Optional LabSolutions Link enables centralized deployment across multi-instrument networks while maintaining individual instrument traceability.

Applications

  • Pharmaceutical manufacturing: PW/WFI system monitoring, cleaning validation, and bioburden risk assessment
  • Environmental laboratories: EPA-regulated wastewater discharge reporting, drinking water compliance (EPA Method 415.3), and groundwater remediation tracking
  • Power generation: Boiler feedwater purity assurance and condensate loop contamination diagnostics
  • Academic and contract research: Method development for complex matrices (e.g., humic-rich surface waters, digested biosolids)
  • Microelectronics: UPW qualification per SEMI F63 and ASTM D5127 standards

FAQ

Is this unit factory-refurbished or dealer-certified pre-owned?
This TOC-L CSN is a professionally inspected and functionally validated pre-owned unit, tested in accordance with Shimadzu’s operational verification protocol (OQ-PV-TOC-L) at SpectraLab Scientific’s ISO/IEC 17025-accredited facility.
Does the 6-month warranty cover parts, labor, and on-site service?
Yes—the warranty includes all components, labor, and remote technical support; on-site service is available in North America and EU regions under extended service agreement terms.
Can the system be requalified for GMP environments?
Absolutely. Full IQ/OQ documentation templates and vendor-supported PQ protocols are available upon request; installation qualification kits include as-delivered performance verification reports.
What software version is installed, and is upgrade support included?
The unit ships with TOC-L Control Software v3.4.2; free minor-version updates are provided for 12 months post-delivery, and major-version upgrades are available under maintenance contracts.
Are consumables (catalysts, NDIR cells, quartz tubes) included or available separately?
Standard consumables inventory—including Pt-catalyst cartridges, quartz combustion tubes, and CO2 sensor calibration kits—is maintained in stock and supplied with lead times under 5 business days.