Model DJH-24L-L to DJH-220L-M
Power Supply 220 V, 50 Hz
Temperature Range RT+10 °C to 250 °C (L-series) / RT+10 °C to 300 °C (M-series)
Temperature Resolution ±0.1 °C
Temperature Uniformity ±0.5 °C (L-series) / ±1.0 °C (M-series)
Operating Ambient Temperature 5–40 °C
Input Power 500–2870 W (model-dependent)
Chamber Dimensions (W×D×H, mm) 300×300×270 to 600×550×750
External Dimensions (W×D×H, mm) 500×450×440 to 880×770×930
Standard Shelving 2 stainless-steel trays
Timer Range 1–9999 min
Interface RS485 (optional)

Overview

The Jianhu DJH Series High-Temperature Forced-Air Oven is an engineered environmental test chamber designed for precise thermal conditioning, accelerated aging, drying, baking, sterilization, and wax melting applications in industrial laboratories, quality control facilities, and R&D environments. Built upon a robust convection-based heating architecture, the chamber utilizes a high-temperature-rated centrifugal blower and optimized airflow ducting to ensure uniform heat distribution across the working chamber—critical for reproducible thermal exposure in compliance-driven testing protocols. Its operational range spans from ambient +10 °C up to 300 °C (M-series), supporting standardized aging procedures per ASTM D573, ISO 188, and IEC 60068-2-2 for elastomers, polymers, adhesives, and electronic components. The chamber’s dual-wall construction—featuring mirror-finish 304 stainless steel interior and cold-rolled steel exterior with powder-coated finish—ensures long-term corrosion resistance, thermal stability, and ease of cleaning under regulated lab conditions.

Key Features

  • Microprocessor-based P.I.D temperature controller with digital display, offering ±0.1 °C resolution and programmable ramp/soak profiles (optional intelligent LCD controller available)
  • Forced-air circulation system with high-temp motorized fan (continuous-duty rating ≥300 °C), engineered to maintain ≤±0.5 °C chamber uniformity at setpoint (L-series) and ≤±1.0 °C (M-series)
  • Dual safety architecture: independent mechanical over-temperature cut-off switch + electronic limit alarm—automatically de-energizes heaters upon threshold breach
  • RS485 serial interface (optional) enables integration with SCADA systems or PC-based data loggers for audit-ready temperature traceability
  • Chamber interior fabricated from seamless, welded 304 stainless steel with rounded corners to prevent contamination accumulation and support GLP-compliant cleaning validation
  • Standard configuration includes two adjustable, perforated stainless-steel shelves; optional accessories include shelf supports, calibration ports, and external exhaust adapters

Sample Compatibility & Compliance

The DJH series accommodates a broad spectrum of non-volatile, non-explosive samples—including polymer specimens, PCB assemblies, pharmaceutical excipients, ceramic preforms, and metal coatings—within defined thermal load limits. Chamber volume options (24 L to 220 L) allow scalability from benchtop qualification tests to batch-level aging studies. All models are constructed and tested in accordance with IEC 61000-6-3 (EMC emissions) and IEC 61000-6-2 (immunity). While not certified to UL or CE as standalone units, the design adheres to fundamental safety principles aligned with EN 61010-1 for laboratory electrical equipment. For GMP/GLP-regulated environments, optional RS485 logging combined with user-defined calibration intervals supports 21 CFR Part 11-compliant electronic record retention when paired with validated software platforms.

Software & Data Management

The optional RS485 communication port supports Modbus RTU protocol for bidirectional parameter exchange—including real-time temperature reading, setpoint adjustment, timer status, and alarm history retrieval. When interfaced with third-party data acquisition software (e.g., LabVIEW, WinCC, or custom Python-based daemons), users can generate time-stamped CSV logs compliant with internal QA documentation requirements. Firmware retains last-set parameters after power interruption, minimizing procedural deviation during extended aging cycles. No proprietary cloud platform or vendor-locked software is required; all configuration remains locally managed via front-panel controls or external host systems.

Applications

  • Accelerated thermal aging of rubber compounds per ASTM D573 and ISO 188
  • Moisture removal from hygroscopic materials prior to gravimetric analysis (e.g., ASTM D2298)
  • Baking of coated substrates and printed circuit boards before solder reflow simulation
  • Sterilization of glassware and metal tools in non-medical research labs (non-validated process)
  • Melting and homogenization of paraffin, beeswax, and thermoplastic binders in histology and materials prep
  • Pre-conditioning of sensors, batteries, and encapsulated electronics for reliability screening

FAQ

What is the maximum continuous operating temperature for the M-series models?

The M-series chambers are rated for continuous operation up to 300 °C, with thermal insulation and fan assembly qualified for sustained duty at this temperature.

Is calibration certification included with shipment?

Factory calibration data (as-found/as-left) is provided with each unit; NIST-traceable certificate of calibration is available upon request at additional cost.

Can the oven be used for flammable solvent drying?

No. The DJH series lacks explosion-proof construction and intrinsically safe components; it is unsuitable for volatile organic solvents or Class I hazardous locations.

How often should temperature uniformity verification be performed?

Per ISO/IEC 17025 and internal QA policies, chamber uniformity mapping is recommended quarterly—or before critical qualification runs—using a minimum of nine calibrated PT100 probes per IEC 60068-3-5.

Are custom chamber dimensions or voltage configurations available?

OEM modifications (e.g., 110 V/60 Hz, extended depth, or reinforced shelving) can be arranged directly through Jianhu’s engineering team under non-standard order terms.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0