Empowering Scientific Discovery

HuaShengPuXin PT-3900A Fully Automated Purge and Trap Concentrator

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand HuaShengPuXin (HSPX)
Origin Beijing, China
Manufacturer Type Direct Manufacturer
Instrument Category Domestic
Model PT-3900A
Sample Tray Capacity 84 positions
Temperature Control Accuracy ±0.1°C
Trap Desorption Temperature Range 100–350°C
Sample Heating Temperature (Purge Vessel) up to 250°C
Sample Vial Cooling Temperature Range 0–40°C
Water Removal Trap Temp Range Ambient–200°C
Valve & Transfer Line Temp Range Ambient–250°C
Trap Cryo-Focusing Temp Range 0–40°C
Sample Oven Temp Range Ambient–90°C
Hot Water Bath Temp Range Ambient–90°C
Purge Tube Temp Range Ambient–90°C
Desorption Ramp Rate >2000°C/min

Overview

The HuaShengPuXin PT-3900A Fully Automated Purge and Trap Concentrator is an integrated sample preparation system engineered for high-throughput, trace-level analysis of volatile organic compounds (VOCs) in aqueous and solid environmental matrices. It operates on the principle of dynamic headspace extraction: inert gas (typically helium or nitrogen) continuously purges VOCs from a heated or cooled sample matrix into a sorbent-packed trap, where analytes are retained and concentrated. Following purge completion, the trap undergoes rapid thermal desorption—achieving ramp rates exceeding 2000°C/min—before transferring the analytes quantitatively onto a gas chromatograph (GC) or GC–mass spectrometer (GC–MS) for separation and detection. Designed for regulatory compliance and method reproducibility, the PT-3900A supports routine ppb-level quantification across complex environmental samples including drinking water, wastewater, groundwater, soil, sediment, and solid waste—without manual intervention or operator-dependent timing.

Key Features

  • 84-position autosampler tray with programmable vial indexing, enabling unattended operation for multi-day batch processing
  • Independent, high-stability temperature control across nine critical zones: purge vessel oven, hot water bath, purge tube, trap desorption zone, cryo-focusing zone, water removal trap, injection valve, transfer line, and ambient reference sensor—all adjustable in 1°C increments with ±0.1°C accuracy and uniformity
  • Ultra-fast trap desorption capability (>2000°C/min ramp rate) minimizes band broadening and ensures sharp, reproducible GC peaks
  • Dual-mode trap conditioning: automated bake-out and purge cycles prior to each analysis to eliminate carryover and maintain baseline integrity
  • Integrated moisture management: programmable water removal trap (ambient–200°C) with real-time dew-point monitoring to prevent water breakthrough during desorption
  • Modular hardware architecture supporting field-upgradable components—including trap cartridges, valves, and GC interface fittings—ensuring long-term serviceability and alignment with evolving method requirements

Sample Compatibility & Compliance

The PT-3900A is validated for direct integration with EPA Method 502.2, 524.2, 624, and 8260-compliant GC–MS workflows, as well as all referenced Chinese Environmental Protection Standards (HJ series), including HJ 639–2012, HJ 605–2011, HJ 713–2014, HJ 735–2015, HJ 866–2017, HJ 893–2017, and HJ 896–2017. It accommodates standard 40-mL VOC vials with PTFE/silicone septa, 22-mL soil extraction vials (with sparging needle), and custom containers compatible with ASTM D3699 and ISO 15681-2 sampling protocols. All thermal zones meet GLP audit requirements for calibration traceability; temperature logs are timestamped and stored with instrument metadata to support 21 CFR Part 11–compliant data integrity frameworks when paired with validated LIMS or chromatography data systems.

Software & Data Management

The embedded control software provides ISO/IEC 17025-aligned method development tools, including multi-step temperature programming, purge gas flow profiling (0–100 mL/min, mass-flow controlled), and trap desorption timing optimization. Each run generates a complete audit trail: setpoint vs. actual temperature profiles per zone, valve actuation timestamps, trap bake-out history, and vial position tracking. Raw method files (.pmt) are encrypted and digitally signed; export formats include CSV for QC reporting and XML for seamless ingestion into enterprise-grade CDS platforms (e.g., Thermo Chromeleon, Agilent OpenLab, Waters Empower). Remote diagnostics and firmware updates are supported via secure TLS 1.2–encrypted Ethernet connection—no cloud dependency or third-party telemetry.

Applications

  • Regulatory monitoring of VOCs in municipal drinking water supplies per national and provincial environmental quality standards
  • Site characterization and remediation verification at brownfield locations, including chlorinated solvents (PCE, TCE), BTEX compounds, and petroleum hydrocarbons (C6–C9)
  • Soil and sediment analysis for legacy contamination under GB/T 32722–2016 and HJ 605–2011
  • Food and beverage safety screening for off-flavor compounds (e.g., geosmin, 2-methylisoborneol) and process contaminants (e.g., chloropropanols)
  • Wastewater treatment plant influent/effluent profiling to assess removal efficiency of volatile pollutants
  • Research applications in atmospheric chemistry, where headspace VOC emissions from biogenic or anthropogenic sources require preconcentration prior to isotopic ratio analysis

FAQ

Does the PT-3900A support both aqueous and solid-phase samples without hardware modification?
Yes—the system includes interchangeable purge vessels and sparging manifolds optimized for liquid samples (40-mL vials) and solid matrices (22-mL soil vials with heated agitator option), all controlled via software-selectable method templates.
Can the trap desorption temperature be ramped linearly or held isothermally?
Both modes are supported: users may define multi-segment temperature programs—including hold times at intermediate temperatures—to optimize elution profiles for co-eluting analytes.
Is the water removal trap reusable, and how is its lifetime monitored?
The water trap uses regenerable molecular sieve cartridges; software tracks cumulative purge gas volume and peak water signal intensity to trigger maintenance alerts before breakthrough occurs.
What GC interfaces are compatible with the PT-3900A?
Standard 1/8″ or 1/16″ stainless-steel transfer lines with Swagelok fittings; optional split/splitless inlet adapters and cryo-focused interfaces for ultra-trace work are available as factory-installed options.
How is method validation documented for regulatory submissions?
The system exports full calibration reports (including NIST-traceable thermocouple verification), system suitability test logs (e.g., surrogate recovery, internal standard precision), and raw chromatographic metadata—structured to align with OECD GLP Annex III and CNAS-CL01:2018 reporting requirements.