Empowering Scientific Discovery

GZX-9076MBE Microcomputer-Controlled Forced-Air Drying Oven

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Origin Beijing, China
Manufacturer Type Authorized Distributor
Product Origin Domestic (PRC)
Model GZX-9076MBE
Quotation Available Upon Request
Power Supply AC 220 V ±10%, 50 Hz ±2%
Temperature Range Ambient +5 °C to 300 °C
Temperature Resolution 1 °C
Temperature Fluctuation ±1 °C
Temperature Uniformity ±1 °C
Input Power 1500 W
Interior Dimensions (W×D×H) 450 × 400 × 450 mm
Exterior Dimensions (W×D×H) 740 × 530 × 630 mm
Shelf Capacity 2 adjustable stainless-steel shelves
Timer Range 0–999 minutes

Overview

The GZX-9076MBE Microcomputer-Controlled Forced-Air Drying Oven is a precision-engineered laboratory drying and thermal processing instrument designed for consistent, uniform heat distribution across demanding applications in quality control laboratories, R&D facilities, pharmaceutical production environments, and academic research settings. Operating on the principle of forced convection via a high-efficiency axial fan and optimized airflow channeling, this oven ensures rapid thermal equilibration and minimal spatial temperature deviation—critical for moisture removal, pre-weighing sample conditioning, polymer curing, powder drying, sterilization of glassware, and wax melting protocols. Its operational envelope spans from ambient +5 °C up to 300 °C, supporting both low-temperature desiccation and high-temperature dry-heat sterilization procedures in compliance with standard laboratory thermal validation practices.

Key Features

  • Microprocessor-based PID temperature controller with real-time digital display, enabling precise setpoint regulation and stable thermal maintenance.
  • Intelligent power-loss recovery function: automatically resumes prior operating parameters—including temperature setpoint and timer value—following unexpected power interruption or system reset.
  • Streamlined arc-shaped cabinet design fabricated from cold-rolled steel with electrostatic epoxy-polyester powder coating for corrosion resistance and mechanical durability.
  • Interior chamber constructed from mirror-finish 304 stainless steel with rounded, semi-circular corners to eliminate crevices and facilitate ISO-compliant cleaning and residue-free decontamination.
  • Dual high-brightness LED displays show both set temperature and actual chamber temperature simultaneously; intuitive membrane keypad interface supports tactile parameter adjustment without tools.
  • High-performance imported brushless DC motor driving a balanced aluminum alloy impeller, delivering laminar, low-turbulence air circulation with minimal vibration transmission.
  • Large-view tempered glass observation window integrated into the double-layer insulated door, sealed using nano-composite silicone gasket material to maintain thermal integrity and minimize energy loss.
  • Two independently adjustable stainless-steel shelving tiers, compatible with standard laboratory tray dimensions and configurable to accommodate varied sample geometries and loading densities.

Sample Compatibility & Compliance

The GZX-9076MBE accommodates a broad range of sample formats including Petri dishes, weighing boats, crucibles, glass vials, metal trays, and ceramic tiles—provided they remain within the maximum load capacity and do not obstruct airflow pathways. It meets fundamental safety and performance criteria outlined in GB/T 5170.2–2017 (Electrical Equipment Environmental Testing—Part 2: Temperature Test Methods) and aligns with general-purpose requirements referenced in ASTM E145–22 (Standard Specification for Gravity-Convection and Forced-Ventilation Ovens). While not certified as a Class II biological safety device or medical-grade sterilizer, its validated thermal uniformity (±1 °C) and repeatability support GLP-aligned documentation workflows when paired with external calibrated thermocouple mapping systems.

Software & Data Management

This model operates as a standalone hardware platform with no embedded PC software or network connectivity. All operational data—including elapsed time, current temperature, and user-defined setpoints—are retained locally in non-volatile memory. The microcontroller logs critical event timestamps (e.g., alarm activation, power restoration) internally, though audit-trail export requires manual transcription or integration with external data loggers compliant with FDA 21 CFR Part 11 requirements. For regulated environments, users are advised to implement supplementary validation protocols—including IQ/OQ/PQ documentation—and periodic recalibration against NIST-traceable reference standards.

Applications

  • Moisture content determination per AOAC 950.46 and USP <731> guidelines.
  • Drying of filter papers, soil samples, and particulate matter prior to gravimetric analysis.
  • Curing of coatings, adhesives, and composite resins under controlled thermal ramp profiles.
  • Pre-sterilization conditioning of reusable labware in microbiology and cell culture facilities.
  • Melting and homogenization of paraffin, beeswax, and low-melting-point polymers in histology and materials labs.
  • Accelerated aging studies for packaging stability testing under defined thermal stress conditions.

FAQ

Is the GZX-9076MBE suitable for sterilization of surgical instruments?
No—it is not classified as a medical-grade sterilizer and lacks validation for microbial lethality curves required under ISO 17665 or EN 285. It may be used for dry-heat depyrogenation of glassware at ≥250 °C for ≥30 minutes, provided additional verification is performed.
Can external temperature probes be connected to monitor internal chamber gradients?
The unit does not feature analog/digital I/O ports. However, third-party calibrated thermocouples can be inserted through the observation window gasket seal for independent mapping during qualification studies.
What maintenance is recommended for long-term reliability?
Monthly inspection of door seal integrity, quarterly cleaning of fan inlet grilles and rear ventilation ducts, and annual verification of temperature sensor calibration using a traceable reference thermometer.
Does the oven comply with CE or UL safety directives?
It conforms to China’s CCC mandatory certification requirements (GB 4706.1–2005) but does not carry CE, UL, or CSA marks. Export configurations require regional safety certification by authorized test laboratories.