Added to wishlistRemoved from wishlist 0
Add to compare
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelACQ-06
PricingAvailable Upon Request
Instrument TypeLiquid Chromatography Column Switching Module
Fluidic Path MaterialsSS316L, PTFE, ETFE, PEEK
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
ModelFL-C100
TypeMixed-Mode Fraction Collector
Collection AxesX-Y Dual-Axis
Positioning Accuracy≤ ±0.5 mm
Compatible Vessel TypesConical Flasks, Round-Bottom Flasks, Beakers, Test Tubes
Waste/Collection Channel SwitchingDual-Path Solenoid-Valve Controlled
Power Supply100–240 VAC, 50/60 Hz
Dimensions (W×D×H)420 × 480 × 450 mm
Weight28 kg
OriginTianjin, China
Regulatory ComplianceCE-marked per EN 61010-1 for Laboratory Equipment
Added to wishlistRemoved from wishlist 0
Add to compare
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Regional OriginDomestic (PRC)
ModelATS-051
Instrument TypeLiquid Chromatography Autosampler
Sample Channels5
Wash Channel1
Loop Volumes1 mL, 10 mL, 25 mL
Injection Volume Range1–25 mL
Wash Volume5 mL (programmable wash modes + manual override)
Language InterfaceEnglish
Operating Temperature20–35 °C
Dimensions (L×W×H)361 × 208.5 × 344.4 mm
Weight11.4 kg
Power Supply100–120 VAC / 200–240 VAC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
ModelATS-051
Instrument TypePreparative HPLC/LC Autosampler
Maximum Sample Capacity5 vials
Minimum Sample Volume per Injection1 mL
Loop Volume Range2–20 mL
Positioning Accuracy±0.1 mm (verified by encoder feedback)
Drive MechanismPrecision Syringe Pump
Needle WashIntegrated Solvent Flush with Dual-Path Solvent Selection
Repeat Injection CapabilityUnlimited cycles per sample
Maximum Single Injection Volume50 mL
CompatibilityStandalone operation or integration with third-party preparative LC systems (e.g., Gilson, Biotage, Teledyne ISCO, Shimadzu, Waters)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
ModelCC-100
OriginTianjin, China
Temperature RangeAmbient +5°C to 100°C
Temperature Stability±0.1°C
Temperature Uniformity±0.3°C (across chamber)
Control MethodPID digital control with touch keypad
DisplayLED digital display
Safety FeaturesOver-temperature protection cutoff
Chamber DesignVertical upright configuration with magnetic-latch dual-layer lid (outer magnetic cover + insulated inner cover)
Power SupplyAC 220 V, 50 Hz
Dimensions (W×D×H)260 × 320 × 380 mm
Net Weight8.5 kg
CoolingNone (heating-only operation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
TypeLiquid-phase Fraction Collector
Max Flow Rate1 L/min
Collection Vessel Options13 mm, 15 mm, 18 mm, 25 mm test tubes & 100 mL conical flasks
Collection ModesFull-collection, Manual-triggered, Threshold-triggered (peak-based), Waste/Collection Switching
Tube Rack CompatibilityF1–F4 standard racks (13–25 mm) + custom rack support
InterfaceRS-232
DesignMulti-channel bow-shaped collection head with adjustable software-defined coordinates
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
ModelATS-A5
Instrument TypeLiquid Chromatography Autosampler
Sample Capacity108 × 2 mL vials (standard), optional configurations available
Injection ModesFull-loop, Partial-loop, and Needle-in-Loop (NIL) injection
Injection Volume Range0.1–25 µL (with standard loop)
PrecisionRSD < 0.25% (full-loop), < 0.5% (partial-loop, >10 µL), < 0.8% (NIL, <5 µL)
Carryover< 0.05%
Maximum System Pressure40 MPa (standard HPLC), 60 MPa (UHPLC-compatible)
Safety FeaturesVial-missing detection, needle-strike alarm, tubing blockage detection, leak monitoring
OptionalPeltier-based sample cooling module
Dimensions (W×D×H)300 × 450 × 320 mm
Weight~25 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
Instrument TypeRefractive Index Detector (RID)
Flow Rate Range1–50 mL/min
Flow Cell Volume7 µL
Temperature Control Range35–55 °C (adjustable in 1 °C increments
Flow Cell Pressure Rating6 kg/cm²
Internal Cell Dead Volume88 µL or 353 µL (selectable)
Linear Range0–2000 µRIU
Noise Level≤10 × 10⁻⁸ RIU
Drift (Full-Scale)<1 mV/hour with 1 mL/min H₂O flow
Auto-Zero FunctionYes
Integrated Flush ValveYes
Digital InterfaceRS-232 (bidirectional parameter transmission)