Empowering Scientific Discovery

Agela Technologies / Phenomenex

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
ModelCH-200P
Application LevelLaboratory Grade
Instrument TypeMedium-to-Low Pressure Preparative LC
Maximum Operating Pressure200 psi (1.38 MPa)
Flow Rate Range1–200 mL/min
UV Detection Wavelength Range200–600 nm
Gradient CapabilityBinary Gradient
Column CompatibilityFlash columns (4–800 g silica/C18), max. sample load: 80 g
Collection ModesFull collection, peak-based collection, manual collection, time-window collection
Real-time Fraction MappingColor-coded tube assignment per detected peak
Purge FunctionIntegrated air pump module for manual/automated column purging
InterfaceTouchscreen GUI with transparent fluidic pathway visualization
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelFL-H100G
Application LevelLaboratory-Scale
Instrument TypeHigh-Pressure Preparative Liquid Chromatograph
Flow Rate Range0–100 mL/min
Flow Accuracy±1 %
Maximum Operating Pressure20 MPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
ModelZAM4000
Detection PrincipleEvaporative Light Scattering
Flow Rate Range1–50 mL/min
Nebulizing Gas Pressure3.5–5 bar
Nebulizing Gas Flow Rate1.7 L/min
Auxiliary Drying Gas Flow Rate<2 m/min
Evaporator Temperature RangeAmbient to 85 °C
Light SourceTungsten Lamp
DetectorPhotomultiplier Tube (PMT)
Output Signal0–5 V Analog + RS-232 Digital
Power-Saving ModeEnables independent shutdown of gas, lamp, heater, and PMT
Fault MonitoringReal-time diagnostics for gas flow, heater, lamp, and PMT failure
雾化气流控制Integrated electronic pressure controller for nebulizer gas
Auxiliary drying gas controlBuilt-in controller
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
ModelOCTOPUS
Application LevelLaboratory-grade
Instrument TypeMedium- to Low-Pressure Preparative LC System
Flow Rate Range1–200 mL/min
Flow Accuracy±1%
Flow Precision (RSD)≤2%
Maximum Pressure20 MPa
Wavelength Accuracy±1 nm
Wavelength Repeatability1 nm
Baseline Noise±5 × 10⁻⁵ AU
Data Acquisition FrequencyNot Specified
Gradient ConfigurationBinary or Quaternary Pump Options
Compatible DetectorsPDA, ELSD, RI
Automation FeaturesAuto-sampler, Column Switcher, Intelligent Fraction Collector with Vial Rack ID Recognition and Solvent/Waste Level Sensing
Column CompatibilityFlash cartridges, medium-pressure glass columns, high-pressure stainless-steel columns
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelFL-H050G
Application LevelLaboratory-Scale
Instrument TypeHigh-Pressure Preparative HPLC System
Flow Rate Range0.1–50 mL/min
Flow Accuracy±1% RSD
Maximum Operating Pressure30 MPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
ModelFLEXA-MH
Application LevelLaboratory Grade
Instrument TypeMedium-to-Low Pressure Preparative LC
Flow Rate Range1–200 mL/min
Flow Accuracy±2%
Flow Precision (RSD)≤2%
Maximum Pressure10 MPa
Wavelength Range200–800 nm (selectable dual-wavelength mode)
Wavelength Accuracy±1 nm
Wavelength Repeatability0.2 nm
Baseline Noise±0.75 × 10⁻⁵ AU at 254 nm, TC = 1 s
Data Acquisition RateNot specified
Detection OptionsUV-Vis (dual-wavelength), optional ELSD or RI detector
Gradient CapabilityBinary gradient, supporting linear, isocratic, and custom profiles
Column ConfigurationCompatible with both reversed-phase and normal-phase chromatography
Collection ModeX/Y-axis programmable fraction collector
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelASTRA
Application LevelLaboratory Grade
Instrument TypeMedium-Low Pressure Preparative Liquid Chromatograph
Flow Rate Range1–200 mL/min
Maximum Operating Pressure200 psi
UV-Vis DetectionPDA Detector, 200–800 nm
Gradient CapabilityQuaternary Solvent Selection
Column CompatibilityNormal- & Reversed-Phase Columns (4–800 g), Max. Sample Load: 80 g
Fraction Collection ModesFull Collection, Peak-Based Collection, Manual Trigger, Time-Window Collection
Added to wishlistRemoved from wishlist 0
Add to compare
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelCHEETAH MP100
Price RangeUSD 14,000–28,000
Application LevelLaboratory-Scale
Instrument TypeMedium-Low Pressure Preparative HPLC
Flow Rate Range1–100 mL/min
Flow Accuracy±2%
Flow Precision (RSD)±2%
Maximum Operating Pressure200 psi
Wavelength Range200–400 nm (standard detector)
Wavelength Accuracy±1 nm
Baseline Noise3 × 10⁻⁴ AU
Data Acquisition Frequency3 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelHS-1000
Instrument TypeFast Liquid Chromatography System
Flow Rate Range0.1–100.0 mL/min (0.1 mL/min increment)
Maximum Operating Pressure≤20 MPa
Fraction Collection OptionsF1–F4 standard tube racks (13 mm, 15 mm, 18 mm, 25 mm OD), F5 conical flask rack (up to 100 mL
Sample Injection Volume Rangeup to 1 L
Temperature ControlAmbient only
Wavelength RangeDual-channel UV-Vis detection at 200–400 nm and 200–800 nm (simultaneously selectable)
Data Acquisition RateNot specified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic
ModelWHALE HP
Application LevelLaboratory-Scale
Instrument TypeHigh-Pressure Preparative LC System
Flow Rate Range300–1000 mL/min
Flow Accuracy±3%
Pressure Rating10 MPa (pump max: 5 MPa)
UV-Vis DetectionPDA with 200–800 nm scanning range
Fraction Collection6-position valve-based collector + 1 solvent recovery channel
Column CompatibilityDAC columns (100–200 mm i.d.) or Flash cartridges (800–5000 g)
Sample LoadingIntegrated liquid loading module, up to 1000 mL/min
Data AcquisitionReal-time spectral scanning and peak-triggered collection
Solvent Recovery ModeSpectral purity assessment-enabled solvent reuse
Collection ModesFull collection, peak collection, manual trigger, time-window collection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic HPLC System
ModelLC-10F
Instrument TypeConventional Analytical HPLC
Flow Rate Range1–9.999 mL/min
Maximum Operating Pressure42 MPa
Injection Volume Range1–20 µL
Wavelength Range200–800 nm
Data Acquisition RateUp to 60 Hz (programmable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Region of OriginDomestic (China)
ModelFLEXA
Price RangeUSD 14,000 – 28,000
Application LevelLaboratory-Scale
Instrument TypeMedium-to-Low Pressure Preparative Liquid Chromatography
Flow Rate Range1–100 mL/min (FLEXA GP100), 1–200 mL/min (FLEXA GP200), 1–30 L/min (FLEXA GP030)
Flow Accuracy±2%
Flow Precision (RSD)±2%
Maximum Operating Pressure200 psi
Wavelength Range200–400 nm (FL-UV2040), 200–800 nm (FL-UV2080/2080B)
Wavelength Accuracy±1 nm
Wavelength Reproducibility±1 nm
Baseline Noise≤3 × 10⁻⁴ AU
Data Acquisition Rate3 Hz
Gradient Composition Accuracy±1%
Gradient ModesBinary, Linear, Isocratic, and Custom Profiles
Detector ChannelsDual-Wavelength Simultaneous Detection
UV SourceDeuterium Lamp (200–400 nm), Tungsten Lamp (400–800 nm)
Collection Vessels13 mm, 15 mm, 18 mm, 25 mm test tubes, and 100 mL Erlenmeyer flasks
Fraction Trigger ModesFull Collection, Manual Trigger, Threshold-Based Peak Detection
Communication InterfaceRS-232
Added to wishlistRemoved from wishlist 0
Add to compare
OriginTianjin, China
Manufacturer TypeDistributor
Origin CategoryDomestic
ModelFLEXA
Price RangeUSD 14,000–28,000 (FOB)
Application LevelLaboratory-Scale
Instrument TypeHigh-Pressure Preparative LC
Flow Rate Range1–50/100 mL/min
Flow Accuracy±0.5%
Flow Precision±0.1%
Maximum Pressure30/20 MPa
Wavelength Range±1 nm
Wavelength Repeatability±0.2 nm
Baseline Noise±0.75 × 10⁻⁵ AU
Data Acquisition Frequency3 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelHS-2900P II
Application LevelLaboratory Grade
Instrument TypeHigh-Pressure Preparative LC
Flow Rate Range1–100 mL/min
Maximum Operating Pressure20 MPa
UV-Vis Wavelength Range200–800 nm
Touchscreen Interface12-inch Capacitive Display
Autosampler Volume Range1–20 mL
Fraction Collection ModesPeak-based, Full-run, Manual, Time/UV Window-triggered
Compatible Collection Vessels15 mm, 18 mm, 25 mm ID tubes and custom containers
Pump ConfigurationDual High-Precision Plunger Pumps
Gradient Mixing Accuracy≤0.5% RSD
Column CompatibilityStatic HPLC prep columns (10–50 mm ID)
SoftwareDedicated preparative chromatography control suite with user permission hierarchy and 21 CFR Part 11-compliant audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Regional OriginDomestic (China)
ModelCHEETAH HP100
Price RangeUSD 42,000 – 56,000
Application LevelLaboratory-Scale
Instrument TypeHigh-Pressure Preparative HPLC System
Flow Rate Range0.1–100.0 mL/min
Flow Accuracy±1%
Flow Precision (RSD)±1%
Maximum Pressure20 MPa
Wavelength Range200–400 nm / 800 nm (dual-channel)
Wavelength Accuracy±1 nm
Wavelength Repeatability±1 nm
Baseline Noise≤3 × 10⁻⁴ AU
Data Acquisition Frequency3 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
ModelCHEETAH II
Instrument TypeFast Liquid Chromatography (Flash)
Flow Rate Range1–200 mL/min
Maximum Operating Pressure200 psi
Sample Injection Positions1–100
Injection Volume Ratio1–10%
Temperature Control25°C (ambient, non-thermostatted)
Wavelength Range200–800 nm
Data Acquisition FrequencyNot specified (system supports real-time UV/VIS spectral scanning)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
ModelLC2000
Instrument TypeConventional HPLC System
Flow Rate Range0.001–10.000 mL/min
Max Operating Pressure≤70 MPa
Flow Accuracy±1%
Injection Volume Range0–100 µL (standard)
Sample CapacityVial tray & 96-well plate compatibility
Column Oven Temperature Range4–90 °C
UV-Vis Wavelength Range190–800 nm
Data Acquisition Rate100 Hz
Flow Precision (RSD)≤0.075%
Pressure Pulsation≤0.2 MPa or ≤1%
Wavelength Accuracy±1 nm
Wavelength Repeatability±0.1 nm
Baseline Noise (UVD)±5 µAU
Baseline Drift (UVD)1×10⁻⁴ AU/h
Flow Cell Volume2.5 µL (5 mm path) / 13 µL (10 mm path)
Injection Carryover<0.002%
Temperature Stability±0.1 °C
Column Compatibilityup to 300 mm length
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelMP200
Price RangeUSD 14,000–28,000
Application LevelLaboratory-Scale Purification
Instrument TypeMedium-Pressure Preparative LC
Flow Rate Range1–200 mL/min
Flow Accuracy±2%
Flow Precision (RSD)≤2%
Maximum Operating Pressure200 psi
Detection Wavelength RangeNot Specified
Wavelength ReproducibilityNot Specified
Baseline NoiseNot Specified
Data Acquisition FrequencyNot Specified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelFLEXA HP 100
Application LevelLaboratory-Scale
Instrument TypeHigh-Pressure Preparative LC System
Flow Rate Range1–100 mL/min
Flow Accuracy±1%
Flow Precision (RSD)≤1%
Maximum Pressure20–30 MPa
Wavelength Range (UV-Vis Detector)190–800 nm
Wavelength Reproducibility±1 nm
Baseline Noise (UV-Vis, 254 nm, 1 s)< ±2.5 × 10⁻⁵ AU
Data Acquisition RateUp to 20 Hz
Detector OptionsUV-Vis, ELSD, RI
Fraction Collection ModesTime-based, Peak-triggered, Threshold-based, User-defined Coordinates
Communication InterfaceRS-232, Optional Ethernet/USB
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
ModelFL-H1000G
OriginTianjin, China
Instrument TypeHigh-Pressure Preparative LC System
Flow Rate Range0–1000 mL/min
Flow Accuracy±3%
Maximum Operating Pressure10 MPa
Application LevelLaboratory-Scale Purification
ConfigurationModular (Pump, UV/Vis Detector, Fraction Collector, Auto-Sampler, Column Switching Valve)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
ModelCHEETAH Pro CH-200PII
Application LevelLaboratory Grade
Instrument TypeMedium-to-Low Pressure Preparative LC System
Flow Rate Range1–200 mL/min
Maximum Operating Pressure200 psi (1.38 MPa)
UV Detection Wavelength Range200–600 nm
Gradient CapabilityBinary Gradient
Column CompatibilityNormal- and Reversed-Phase Flash Columns (4–800 g), Max Sample Load: 80 g
Fraction Collection ModesFull Collection, Peak-Based Collection, Manual Trigger, Time-Window Collection
Real-Time Tube MappingColor-Coded Fraction Tube Assignment per Peak
Optional Air-Purge ModuleIntegrated Air Pump for Manual/Automatic Flash Column Purging (CH-200PII-Air Variant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelFL-H300G
Application LevelLaboratory-Scale
Instrument TypeHigh-Pressure Preparative HPLC System
Flow Rate Range0.01–300 mL/min
Flow Accuracy±2%
Maximum Operating Pressure15 MPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelHS-D-5800P
Application LevelLaboratory Grade
Instrument TypeHigh-Pressure Preparative Liquid Chromatograph
Flow Rate Range0–150 mL/min
Flow Accuracy±1%
Flow Precision (RSD)<1%
Maximum Operating Pressure40 MPa
UV Detection Wavelength Range200–800 nm
Baseline Noise±0.5 × 10⁻⁵ AU
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgela
ModelLC-10F
OriginTianjin, China
Instrument TypeConventional HPLC System
Flow Rate Range0.001–9.999 mL/min (0.001 mL/min increment)
Max Operating Pressure≤ 42 MPa (316L stainless steel pump head)
Injection CapacityNot specified
Column Oven Temperature ControlNot specified
UV-Vis Wavelength Range200–800 nm
Wavelength Accuracy±1 nm
Wavelength Repeatability0.2 nm
Baseline Noise±0.75 × 10⁻⁵ AU (254 nm, time constant = 1 s)
Baseline Drift1.5 × 10⁻⁴ AU/h (254 nm)
Flow Accuracy±0.5 % (at 1 mL/min, 10 MPa)
Flow PrecisionRSD ≤ 0.1 % (at 1 mL/min, 10 MPa)
Pressure Pulsation≤ 0.5 % (at 1 mL/min, 10 MPa)
Detector Light SourcesDeuterium lamp (standard), Tungsten lamp (optional)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0