| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | Cleanert V96 |
| Heating Method | Dry-block heating |
| Temperature Control Range | 10°C to 30°C ambient operating environment |
| Temperature Setting Range | Room temperature +5°C to 80°C |
| Temperature Stability | ±0.5°C (typical at setpoint) |
| Gas Flow Rate | 10–100 L/min (adjustable per channel) |
| Sample Capacity | Configurable for 24-, 48-, or 96-well formats via modular gas manifolds |
| Dimensions (W×D×H) | 360 mm × 287 mm × 367 mm |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | NV-15G |
| Heating Method | Dry-block heating |
| Temperature Range | ≥5 °C above ambient to 150 °C |
| Temperature Uniformity | ±0.3 °C |
| Sample Capacity | 15 positions |
| Well Diameter | 19 mm |
| Well Depth | 70 mm |
| Gas Flow Rate | 0–15 L/min (0–100 psi) |
| Power Supply | 220 V / 50 Hz |
| Max. Power | 240 W |
| Net Weight | 4.7 kg |
| Operating Environment | 0–50 °C, ≤85% RH |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | NV15-G |
| Heating Method | Water Bath |
| Temperature Range | >5 °C above ambient to 80 °C |
| Temperature Stability | ±1 °C |
| Sample Tube Diameter | 20 mm |
| Gas Flow Rate | 0–10 L/min |
| Sample Capacity | 8–24 positions |
| Heating Power | 240 W |
| Tube Depth | 70 mm |
| Temp Accuracy | ±0.3 °C (at setpoint) |
| Operating Ambient | 0–50 °C, ≤85% RH |
| Power Supply | 220 V/50 Hz |
| Net Weight | 3.5 kg |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | NV24A-II |
| Sample Capacity | 24 positions |
| Heating Method | Dry-block heating (PTC) |
| Temperature Control | Programmable range with ±0.5 °C stability |
| Endpoint Detection | Optical fiber sensor for precise volume termination at 0.5 mL or 1.0 mL |
| Gas Flow Control | Independent per-channel on/off switching and real-time digital display of flow/pressure |
| Integrated Exhaust | Built-in active exhaust system for volatile organic compound (VOC) removal |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | Cleanert V96 |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient +5°C to 80°C |
| Temperature Uniformity | ±1°C |
| Sample Format | 96-well microplate |
| Gas Flow Rate | 0–80 L/min |
| Heating Power | 450 W |
| Sample Capacity | 96 positions |
| Gas Heating Uniformity | Optimized for consistent thermal delivery across all wells |
| Adjustable Gas Manifold Height | Yes |
| Removable Gas Manifold | Yes |