| Brand | Agela |
|---|---|
| Model | ZAM4000 |
| Detection Principle | Evaporative Light Scattering |
| Flow Rate Range | 1–50 mL/min |
| Nebulizing Gas Pressure | 3.5–5 bar |
| Nebulizing Gas Flow Rate | 1.7 L/min |
| Auxiliary Drying Gas Flow Rate | <2 m/min |
| Evaporator Temperature Range | Ambient to 85 °C |
| Light Source | Tungsten Lamp |
| Detector | Photomultiplier Tube (PMT) |
| Output Signal | 0–5 V Analog + RS-232 Digital |
| Power-Saving Mode | Enables independent shutdown of gas, lamp, heater, and PMT |
| Fault Monitoring | Real-time diagnostics for gas flow, heater, lamp, and PMT failure |
| 雾化气流控制 | Integrated electronic pressure controller for nebulizer gas |
| Auxiliary drying gas control | Built-in controller |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-1000 |
| Instrument Type | Fast Liquid Chromatography System |
| Flow Rate Range | 0.1–100.0 mL/min (0.1 mL/min increment) |
| Maximum Operating Pressure | ≤20 MPa |
| Fraction Collection Options | F1–F4 standard tube racks (13 mm, 15 mm, 18 mm, 25 mm OD), F5 conical flask rack (up to 100 mL |
| Sample Injection Volume Range | up to 1 L |
| Temperature Control | Ambient only |
| Wavelength Range | Dual-channel UV-Vis detection at 200–400 nm and 200–800 nm (simultaneously selectable) |
| Data Acquisition Rate | Not specified |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic HPLC System |
| Model | LC-10F |
| Instrument Type | Conventional Analytical HPLC |
| Flow Rate Range | 1–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Injection Volume Range | 1–20 µL |
| Wavelength Range | 200–800 nm |
| Data Acquisition Rate | Up to 60 Hz (programmable) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | CHEETAH II |
| Instrument Type | Fast Liquid Chromatography (Flash) |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi |
| Sample Injection Positions | 1–100 |
| Injection Volume Ratio | 1–10% |
| Temperature Control | 25°C (ambient, non-thermostatted) |
| Wavelength Range | 200–800 nm |
| Data Acquisition Frequency | Not specified (system supports real-time UV/VIS spectral scanning) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | LC2000 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–10.000 mL/min |
| Max Operating Pressure | ≤70 MPa |
| Flow Accuracy | ±1% |
| Injection Volume Range | 0–100 µL (standard) |
| Sample Capacity | Vial tray & 96-well plate compatibility |
| Column Oven Temperature Range | 4–90 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Flow Precision (RSD) | ≤0.075% |
| Pressure Pulsation | ≤0.2 MPa or ≤1% |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Baseline Noise (UVD) | ±5 µAU |
| Baseline Drift (UVD) | 1×10⁻⁴ AU/h |
| Flow Cell Volume | 2.5 µL (5 mm path) / 13 µL (10 mm path) |
| Injection Carryover | <0.002% |
| Temperature Stability | ±0.1 °C |
| Column Compatibility | up to 300 mm length |
| Brand | Agela |
|---|---|
| Model | LC-10F |
| Origin | Tianjin, China |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increment) |
| Max Operating Pressure | ≤ 42 MPa (316L stainless steel pump head) |
| Injection Capacity | Not specified |
| Column Oven Temperature Control | Not specified |
| UV-Vis Wavelength Range | 200–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±0.75 × 10⁻⁵ AU (254 nm, time constant = 1 s) |
| Baseline Drift | 1.5 × 10⁻⁴ AU/h (254 nm) |
| Flow Accuracy | ±0.5 % (at 1 mL/min, 10 MPa) |
| Flow Precision | RSD ≤ 0.1 % (at 1 mL/min, 10 MPa) |
| Pressure Pulsation | ≤ 0.5 % (at 1 mL/min, 10 MPa) |
| Detector Light Sources | Deuterium lamp (standard), Tungsten lamp (optional) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | Multi-Stage Chromatographic Purification System |
| Instrument Type | Conventional High-Performance Liquid Chromatography (HPLC) System |
| Configuration | Integrated Three-Stage Automated Purification Platform |
| Application Focus | Downstream Processing of Biologics, Natural Product Isolation, and Complex Matrix Sample Purification |
| Compliance Framework | Designed to support GLP-compliant workflows and scalable process development |