Anemometer Air Flow Meter
Filter
Showing 361–390 of 390 results
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | TPJ-30-G |
| Instrument Type | Integrated Wireless Anemometer and Wind Direction Sensor |
| Wind Speed Range | 0–45 m/s |
| Wind Speed Resolution | 0.1 m/s |
| Wind Speed Accuracy | ±(0.3 ± 0.03) m/s |
| Wind Direction Range | 0–359° |
| Wind Direction Accuracy | ±3° |
| Wind Direction Resolution | 2° |
| Startup Wind Speed | ≤0.8 m/s |
| Wind Speed Drift | <0.2 m/s/year |
| Communication | 4G/5G Cellular + USB + Optional RS485 |
| Onboard Storage | 30,000 records (Flash) + expandable microSD (up to 4 GB default, user-replaceable) |
| Power Supply | Internal 7.4 V / 2.8 Ah Li-ion battery with charge protection & low-voltage alert |
| External DC input | 8.4 V / ≥1000 mA |
| GPS | Built-in GNSS module (GPS + BeiDou) for geotagged data logging |
| Operating Temperature | Standard ambient (−20°C to +60°C typical for outdoor environmental deployment) |
| Operating Humidity | Non-condensing, up to 95% RH |
| IP Rating | IP67-rated sensor housing and extension cables |
| Expandability | Up to 32 analog/digital sensor channels via modular hub interface |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8380 |
| Airflow Range | 42–4250 m³/hr |
| Accuracy | ±3% of reading or ±12 m³/hr (for airflow >85 m³/hr) |
| Resolution | 1 m³/hr |
| Velocity Range (Pitot Tube) | 0.125–78 m/s |
| Pressure Differential | ±3735 Pa (max 37.5 kPa) |
| Relative Humidity Range | 5–95% RH |
| Temperature Range | –10–60 °C |
| Data Storage Capacity | 26,500 timestamped samples |
| Interface | USB, Bluetooth |
| Compliance | GB 50591-2010, GB/T 36066-2018, GB/T 50243-2016, CJJ/T 309-2013, YY 0569-2011 |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8380-H |
| Communication Range | Up to 30.5 m via Bluetooth |
| Max. Vertical Extension | 3 m |
| Hood Height Coverage | Up to 4 m |
| Compatible Devices | Android OS 2.3.3 or later (smartphones & tablets) |
| Pressure Connection | Dual 8-ft flexible tubing included |
| Mobility | Casters-equipped base with telescoping two-section extension rods |
| Carry Case | Padded shoulder bag included |
| Software | LogDat™ Mobile App (optional standalone operation without app) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Numbers | 8455, 8465, 8475 |
| Pricing | Available Upon Request |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 9515 |
| Measurement Range | 0–20 m/s |
| Accuracy | ±5% of reading or ±0.025 m/s (whichever is greater) |
| Resolution | 0.01 m/s (wind speed), 0.1 °C (temperature) |
| Temperature Range | –18 to 93 °C (sensor), 5 to 45 °C (host unit) |
| Probe Length | 101.6 cm |
| Probe Tip Diameter | 7.0 mm |
| Probe Base Diameter | 13.0 mm |
| Dimensions (H × W × D) | 8.4 cm × 17.8 cm × 4.4 cm |
| Weight | 0.27 kg |
| Power Supply | 4 × AA batteries |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 9565A |
| Measurement Principles | Thermal Anemometry (for air velocity), Capacitive Hygrometry (for RH), Thermistor (for temperature), Piezoresistive Sensor (for differential pressure) |
| Velocity Range | 0–50 m/s |
| Temperature Range | –10 to +60 °C |
| Relative Humidity Range | 0–95 %RH |
| Differential Pressure Range | –3735 to +3735 Pa |
| Data Storage | 26,500 points across 100 test groups |
| Display | Backlit LCD with Chinese/English bilingual interface |
| Probe Interface | Hot-swappable modular probe bay |
| Compliance | Designed for ASTM D1212, ISO 7726, ASHRAE 111, and GB/T 18204.1–2013 (Chinese national standard for ventilation testing) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | ACCUBALANCE |
| Weight | 3.4 kg (with 610 × 610 mm hood) |
| Air Flow Range | 42–4250 m³/hr |
| Accuracy | ±3% of reading or ±12 m³/hr (for flow >85 m³/hr) |
| Resolution | 1 m³/hr |
| Velocity Range (Pitot Tube) | 0.125–78 m/s |
| Velocity Range (Air Velocity Probe) | 0.125–25 m/s |
| Velocity Range (16-Point Matrix) | 0.125–12.5 m/s |
| Velocity Accuracy | ±3% of reading or ±0.04 m/s |
| Resolution | 0.01 m/s |
| Differential Pressure | ±3735 Pa (max 37.5 kPa) |
| Absolute Pressure | 356–1016 mmHg |
| Pressure Accuracy | ±2% of reading or ±0.25 Pa |
| Relative Humidity Range | 5–95% RH |
| RH Accuracy | ±3% RH |
| RH Resolution | 0.1% RH |
| Temperature Range (Thermistor) | 4.4–60 °C |
| Temp Range (Thermo-Hygrometer Probe) | −10–60 °C |
| Temp Accuracy | ±0.3 °C |
| Temp Resolution | 0.1 °C |
| Power | 4 × AA batteries or AC adapter |
| Interface | USB |
| Operating Temperature | 0–60 °C |
| Standard Hood Size | 610 × 610 mm |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8380 |
| Hood Size | 2 ft × 2 ft (610 mm × 610 mm) |
| Pressure Measurement Range | ±250 Pa |
| Accuracy | ±3% of reading (typical for air flow measurement per ISO 16813 and ASHRAE Guideline 1) |
| Weight | <2.7 kg (6 lbs) |
| Battery | Rechargeable NiMH AA × 4 |
| Data Interface | USB + Bluetooth |
| Compliance | NIST-traceable calibration certificate included |
| Operating Temperature | 10–40 °C |
| Relative Humidity Limit | ≤90% RH non-condensing |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8371 |
| Price Range | USD 2,600–6,500 (est.) |
| Instrument Type | Air Flow Capture Hood |
| Flow Range | 5–1000 L/s (18–3600 m³/h) |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 0–95 % RH (non-condensing) |
| Resolution | 0.1 L/s |
| Accuracy | ±3 % of reading or ±0.5 L/s (whichever is greater) |
| Weight | 3.4 kg (for 610 × 610 mm hood) |
| Power Supply | 4 × C-cell alkaline batteries (40 h continuous operation) |
| Display | Backlit LCD with real-time flow readout |
| Optional Accessories | Portable thermal printer, calibration certificate traceable to NIST |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | AP500 |
| Atmospheric Pressure Range | 517.1–930.9 mmHg (20.36–36.65 inHg) |
| Accuracy (Pressure) | ±2% of reading |
| Operating Temperature (Electronics) | 5–45 °C |
| Storage Temperature | −20–60 °C |
| Battery | Rechargeable Li-ion, 3500 mAh |
| Runtime | >8 h at 0.5 m/s, 25 °C |
| Display | OLED, 10 mm digit height |
| Dimensions (W×L×D) | 53 × 181 × 40 mm |
| Weight (with battery) | 0.23 kg |
| Wind Speed Range (VT-S/VTH-S/VT-A/VTH-A) | 0–30 m/s |
| Wind Speed Accuracy | ±3% of reading or ±0.015 m/s (whichever is greater) |
| Wind Speed Resolution | 0.01 m/s |
| Temperature Range (all probes) | −10–65 °C |
| Temperature Accuracy | ±0.3 °C |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range (VTH-S/VTH-A/TH-S) | 5–95 %RH |
| RH Accuracy | ±3 %RH |
| RH Resolution | 0.1 %RH |
| Probe Length (straight/hinged) | 305 mm |
| Max Probe Diameter | 9.5 mm |
| Hinge Section Length (VT-A/VTH-A) | 152.4 mm |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | AP800 |
| Differential Pressure Range | –3735 to +3735 Pa |
| Accuracy | ±1% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Air Velocity Range (with Pitot tube) | 1.27–78.7 m/s |
| Velocity Accuracy | ±1.5% at 10.16 m/s |
| Barometric Pressure Range | 517.1–930.9 mmHg |
| Operating Temperature | 5–45 °C |
| Display | OLED, 10 mm digit height |
| Dimensions | 53 × 181 × 40 mm |
| Weight | 0.20 kg (with battery) |
| Battery Life | >32 hours |
| Connectivity | Bluetooth Low Energy (BLE), USB-C charging, microSD data logging |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5815 / 5825 |
| Price Range | USD 2,600 – 6,500 |
| Pressure Range | −15 to +15 in. H₂O (−3735 to +3735 Pa) |
| Accuracy | ±0.005 in. H₂O (±1% of reading ±1 Pa) |
| Resolution | 0.001 in. H₂O (1 Pa) |
| Velocity Range (Pitot Tube) | 250–15,500 ft/min (0.27–78.7 m/s) |
| Velocity Accuracy | ±1.5% at 2000 ft/min (10.16 m/s) |
| Resolution | 1 ft/min (0.1 m/s) |
| Duct Size Input (5825 only) | 1–250 in. (0.1-in. increments) |
| Data Storage | 12,700 readings + 100 data sets |
| Sampling Interval | 1 s – 1 h |
| Operating Temperature | 0–70 °C |
| Storage Temperature | −40–85 °C |
| Dimensions | 8.4 × 17.8 × 4.4 cm |
| Weight | 0.27 kg (with batteries) |
| Power | 4 × AA alkaline or optional AC adapter |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8715 |
| Category | Differential Pressure & Multi-Parameter Air Flow Analyzer |
| Resolution | 0.001 Pa (differential pressure) |
| Measurement Range | ±1000 Pa (differential pressure), 0–50 m/s (air velocity, with optional thermal anemometer probes) |
| Accuracy | ±0.5% of reading ±0.005 Pa (DP), ±2% of reading (velocity, typical with calibrated probe) |
| Operating Temperature | 0–50 °C |
| Operating Relative Humidity | 0–95% RH (non-condensing) |
| Interface | USB 2.0 |
| Compliance | Meets requirements referenced in GB/T 50243–2016, GB 50591–2010, WS 394–2012, AQ/T 4271–2015, CJJ/T 309–2013, GB/T 36066–2018 |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 5725 |
| Velocity Range | 0.25–30 m/s |
| Accuracy | ±1% of reading or ±0.02 m/s (whichever is greater) |
| Temperature Range | 0–60 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Duct Area Range | 0–16 m² |
| Data Storage | 12,700 readings across 100 data groups |
| Sampling Interval | 1 s – 1 h |
| Time Constant | User-adjustable |
| Operating Temperature | 5–45 °C |
| Probe Operating Temperature | 0–60 °C |
| Storage Temperature | −20–60 °C |
| Dimensions | 8.4 × 17.8 × 4.4 cm |
| Weight (with batteries) | 270 g |
| Power | 4 × AA alkaline batteries |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 5815, 5825 |
| Pressure Range | −3735 to +3735 Pa (−28.0 to +28.0 mmHg) |
| Pressure Resolution | 0.1 Pa, 0.001 mmHg |
| Pressure Accuracy | ±1% of reading, ±0.01 mmHg, or ±1 Pa (whichever is greater) |
| Air Velocity Range (with Pitot Tube) | 1.27–78.7 m/s |
| Air Velocity Resolution | 0.1 m/s |
| Air Velocity Accuracy | ±1.5% at 10.16 m/s |
| Operating Temperature | 5–45 °C |
| Storage Temperature | −20–60 °C |
| Data Storage Capacity | 12,700 readings across up to 100 data sets |
| Sampling Interval | 1 s to 1 h |
| Dimensions | 8.4 × 17.8 × 4.4 cm |
| Weight (with batteries) | 0.27 kg |
| Power | 4 × AA batteries or optional AC adapter |
| Volume Flow Calculation | Supported via user-defined duct dimensions (1–635 mm, 0.1 mm increments) and programmable K-factor |
| Brand | TSI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 8475 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.07% of Selected Full-Scale Range |
| Measurement Range | 0.05–2.54 m/s |
| Accuracy | ±1.0% of Selected Full-Scale Range |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8715 |
| Differential Pressure Range | ±3735 Pa (Max Safe Operating Pressure: 37350 Pa) |
| Accuracy | ±2% of reading ± 0.25 Pa |
| Resolution | 0.001 Pa |
| Absolute Pressure Range | 356–1016 mmHg |
| Absolute Pressure Accuracy | ±2% of reading |
| Resolution | 1 mmHg |
| Air Velocity Range (Pitot Tube) | 0.13–41 m/s |
| Air Velocity Range (Air Flow Probe) | 0.13–25 m/s |
| Air Velocity Range (Velocity Matrix) | 0.13–13 m/s |
| Air Velocity Accuracy | ±3% of reading ± 0.036 m/s (for v > 0.254 m/s) |
| Resolution | 0.1 m/s |
| Temperature Range (Probe-Dependent) | −40 to 121 °C |
| Temperature Accuracy | ±0.3 °C (0–71 °C), ±0.6 °C (−40–0 °C and 71–121 °C) |
| Resolution | 0.1 °C |
| Relative Humidity Range | 0–95% RH |
| RH Accuracy | ±3% RH |
| Resolution | 0.1% RH |
| Averaging Capacity | Up to 1000 data points (pressure or velocity) |
| Measurement Interval | Continuous or user-selectable (10–600 s) |
| Response Time | 2–8 s |
| Time Constant Options | 1, 5, 10, 15, 20 s |
| Operating Temperature | 4.4–60 °C |
| Dimensions | 188 × 114 × 58 mm |
| Weight | 0.5 kg (including batteries) |
| Power | Four AA alkaline or NiMH rechargeable batteries, or AC adapter |
| Battery Life | ~12 h (alkaline) |
| Internal Charging Time | 5 h |
| External Charging Time | 1 h |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 9515 |
| Air Velocity Range | 0–20 m/s |
| Resolution | 0.01 m/s |
| Accuracy | ±5% of reading or ±0.025 m/s (whichever is greater) |
| Temperature Range | –18 to 93 °C |
| Temperature Accuracy | ±0.3 °C |
| Temperature Resolution | 0.1 °C |
| Probe Length | 101.6 cm |
| Probe Tip Diameter | 7.0 mm |
| Probe Base Diameter | 13.0 mm |
| Host Dimensions | 8.4 × 17.8 × 4.4 cm |
| Operating Temperature (Host) | 5–45 °C |
| Storage Temperature | –20–60 °C |
| Weight (with batteries) | 0.27 kg |
| Power Supply | 4 × AA alkaline or NiCd batteries |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 9535 |
| Pricing | Upon Request |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model Variants | 9535, 9535-A, 9545, 9545-A |
| Resolution | 0.01 m/s |
| Measurement Range | 0–30 m/s |
| Accuracy | ±3% of reading or ±0.015 m/s (whichever is greater) |
| Data Storage | 12,700 points across 100 data sets |
| Sampling Interval | 1 s to 1 h |
| Power | 4 × AA batteries or optional AC adapter |
| Weight (with batteries) | 0.27 kg |
| Probe Length | 101.6 cm (rigid), 19.7 cm (articulating) |
| Probe Diameter | 7.0 mm (rigid), 9.5 mm (articulating) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 9515 |
| Price | Upon Request |
| Air Velocity Range | 0–4000 ft/min (0–20 m/s) |
| Accuracy | ±5% of reading or ±5 ft/min (±0.025 m/s), whichever is greater |
| Resolution | 1 ft/min (0.01 m/s) |
| Temperature Range | –18 to 93 °C (0 to 200 °F) |
| Temperature Accuracy | ±0.3 °C (±0.5 °F) |
| Temperature Resolution | 0.1 °C (0.1 °F) |
| Operating Temperature (Instrument) | 5–45 °C (40–113 °F) |
| Operating Temperature (Sensor, 9515) | –18–93 °C (0–200 °F) |
| Storage Temperature | –20–60 °C (–4–140 °F) |
| Dimensions (9515) | 8.4 × 17.8 × 4.4 cm (3.3 × 7.0 × 1.8 in) |
| Probe Length (9515) | 101.6 cm (40 in) |
| Probe Tip Diameter (9515) | 7.0 mm (0.28 in) |
| Probe Base Diameter (9515) | 13.0 mm (0.51 in) |
| Weight (with batteries) | 0.27 kg (0.6 lb) |
| Power Supply | 4 × AA batteries |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | VELOCICALC 9565 |
| Measurement Range | 0–20 m/s |
| Display | 5-parameter simultaneous readout |
| Data Storage | 26,500 points across 100 test groups |
| Probe Interface | Smart interchangeable probe system (vane, pitot tube, CO₂, VOC) |
| Pressure Range (Differential/Static) | ±15 in. H₂O (±3735 Pa) |
| Accuracy (Air Velocity, Pitot Mode) | ±2% of reading ±0.03 m/s at 10.16 m/s |
| Resolution (Velocity) | 0.01 m/s |
| Resolution (Pressure) | 0.001 in. H₂O (0.1 Pa) |
| Dimensions | 9.7 × 21.1 × 5.3 cm |
| Weight (with batteries) | 0.36 kg |
| Power | 4 × AA alkaline or optional AC adapter |
| Communication | Bluetooth v4.0 + USB |
| Compliance | Designed for HVAC commissioning per ASHRAE Guideline 1, ISO 16813, and ANSI/ASHRAE Standard 62.1 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 9565 Series |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5725 |
| Instrument Type | Vane Anemometer |
| Velocity Range | 0.25–30 m/s (50–6000 ft/min) |
| Accuracy (Velocity) | ±1.0% of reading or ±0.02 m/s (±4 ft/min), whichever is greater |
| Temperature Range | 0–60 °C (32–140 °F) |
| Temperature Accuracy | ±0.5 °C (±2 °F) |
| Temperature Resolution | 0.1 °C (0.1 °F) |
| Duct Area Range | 0–16 m² (0–173.6 ft²) |
| Volume Flow Calculation | Enabled via user-input duct geometry/area |
| Operating Temp (Instrument) | 5–45 °C |
| Operating Temp (Probe) | 0–60 °C |
| Storage Temp | −20–60 °C |
| Data Memory | 12,700 readings + 100 data sets |
| Sampling Interval | 1 s – 1 h |
| User-Defined Time Constant | Yes |
| Display | Real-time velocity, temperature, min/max, and rolling average |
| Probe | 100 mm (4 in.) bidirectional vane |
| Dimensions | 8.4 × 17.8 × 4.4 cm |
| Weight (with battery) | 270 g |
| Power | One 9V alkaline or NiCd battery |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 9535 / 9535-A / 9545 / 9545-A |
| Instrument Type | Hot-Wire Anemometer |
| Resolution | 0.01 m/s |
| Velocity Range | 0–30 m/s |
| Accuracy | ±3% of reading (for 0.15–30 m/s at 25°C) |
| Operating Temperature | –18°C to +93°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Temperature Compensation | ±0.03°C/°C deviation from 25°C |
| RH Compensation | ±0.2% RH/°C (including 1% hysteresis) |
| Data Storage | 12,700 samples + 100 test IDs |
| Included Software | LogDat2™ data download and analysis software |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | VelociCalc™ 9600 / 9630 / 9650-NB |
| Air Velocity Range (Pitot Tube, 9630/9650-NB) | 1.27–78.7 m/s |
| Accuracy (at 10.16 m/s) | ±1.5% |
| Resolution | 0.01 m/s |
| Static/Differential Pressure Range | −3735 to +3735 Pa |
| Accuracy | ±1% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Barometric Pressure Range | 517.15–930.87 mmHg |
| Operating Temperature | 5–45 °C |
| Dimensions | 8.1 × 24.1 × 4.1 cm |
| Weight | 0.41 kg |
| Data Storage | 200 test IDs / 162,200 samples |
| Sampling Interval | 1 s – 1 h |
| Time Constants | 1, 5, 10, 20, 30, 60, 90 s |
| Brand | Vaisala |
|---|---|
| Origin | Finland |
| Model | WMT700 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–90 m/s |
| Accuracy | ±2% (0–75 m/s) |
| Operating Temperature | −55°C to +70°C |
| Relative Humidity Range | 0–100% RH |
| IP Rating | IP66 / IP67 |
| Output Rate | Up to 8 Hz |
| Power Supply | 9–36 VDC (sensor), 24–36 VDC (heating variants) |
| Heating Power | Up to 250 W (full-heating model) |
| Communication Interfaces | RS-485, RS-422, RS-232, SDI-12 |
| Compliance | WMO Guide No. 8 (7th ed.), ICAO Annex 3, ISO 16622, IEC 61000-4-2, IEC 60068-2, DNVGL-CG-0339, LR Type Approval, IEC 60945 |
| Brand | Vaisala |
|---|---|
| Origin | Finland |
| Model | WXT532 |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0–60 m/s |
| Accuracy | ±3% @ 10 m/s |
| Operating Temperature | −52 °C to +60 °C |
| Relative Humidity Range | 0–100% RH |
| Ingress Protection | IP65 (without mounting adapter), IP66 (with mounting adapter) |
| Output Options | SDI-12 v1.3, RS-232, RS-485, RS-422, NMEA 0183 v3.0 |
| Analog Outputs (optional) | 0–20 mA or 4–20 mA for wind speed and wind direction |
| Power Supply | 6–24 VDC |
| Typical Current Consumption | 3 mA @ 12 VDC (default measurement interval) |
| Heater Supply | 12–24 VDC / 12–17 VAC |
| Heater Current | 0.8 A @ 12 VDC, 0.4 A @ 24 VAC |
| Response Time | 0.25 s |
| Wind Direction Range | 0–360° |
| Wind Direction Accuracy | ±3° @ 10 m/s |
| Wind Direction Resolution | 1° |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WM-200 |
| Instrument Type | Vane Anemometer |
| Resolution | ±1 °C (temperature) |
| Measurement Range | -85 to 8942.8 m (altitude estimation, not direct measurement) |
| Accuracy | ±3% of reading (wind speed) |
| Operating Temperature | -30 °C to +70 °C |
| Operating Humidity | 0–100% RH (non-condensing) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | WINBLOG™-8041005 |
| Price | USD 4,850 (FOB Hamburg) |
| Wind Speed Range | 0–68 m/s |
| Wind Speed Accuracy | ±3% of full scale |
| Startup Wind Speed (Speed) | 0.4 m/s |
| Wind Direction Range | 0–360° |
| Wind Direction Accuracy | ±3° |
| Startup Wind Speed (Direction) | 0.8 m/s |
| Output Options | RS232 digital interface |
| Optional analog outputs | 4–20 mA or 0–1 V |
| Sensor Type | Three-cup anemometer (speed), vane-type wind vane (direction) |