Anemometer Air Flow Meter
Filter
Showing 31–60 of 390 results
| Brand | GILL |
|---|---|
| Origin | United Kingdom |
| Model | WindSonic |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s (wind speed), 1° (wind direction) |
| Measurement Range | 0–60 m/s (wind speed), 0–359° (wind direction) |
| Accuracy | ±2% @ 12 m/s (wind speed), ±3° @ 12 m/s (wind direction) |
| Response Time | 0.25 s |
| Startup Wind Speed | 0.01 m/s |
| Operating Temperature | −40 to +70 °C |
| Storage Temperature | −40 to +80 °C |
| Humidity Range | 0–100 % RH |
| IP Rating | IP65 |
| Power Supply | 5–30 V DC (varies by output option) |
| Average Time Between Failures (MTBF) | 15 years |
| Housing Material | Luran S KR 2861/1C (ASA/PC blend) |
| Dimensions | 142 mm × 160 mm |
| Weight | 0.5 kg |
| Calibration | Traceable to UK National Standards |
| EMC Compliance | EN 61326:1998 |
| Brand | Gill |
|---|---|
| Origin | United Kingdom |
| Model | WindUltra |
| Instrument Type | Ultrasonic Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0–75 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | 5–100% RH |
| Output Protocols | ASCII, Modbus RTU, NMEA 0183, SDI-12 |
| Heating System | User-configurable low-power resistive heater |
| Brand | Graywolf |
|---|---|
| Model | AS-202A |
| Type | Hot-wire anemometer |
| Measurement Range | 0–30 m/s |
| Accuracy | ±3% of reading |
| Probe Configuration | Articulated (90° bent tip) hot-wire probe |
| Operating System | Wolf OS (embedded real-time OS) |
| Software Platform | Graywolf Professional Suite (DuctCal, HoodCal, VentCal modules optional) |
| Compliance | Designed for ISO 14644-3, ISO 16813, ASHRAE 110, and EN 13725 environmental verification workflows |
| Data Logging | Internal storage + USB/Bluetooth export (CSV, PDF, XML) |
| Environmental Rating | IP54 (dust- and splash-resistant) |
| Brand | Graywolf |
|---|---|
| Model | PIT-504-KIT |
| Type | Pitot Tube Anemometer |
| Measurement Range | 0–100 m/s |
| Accuracy | ±3% |
| Operating Temperature (short-term) | up to 800 °C |
| Operating Temperature (continuous) | up to 680 °C |
| Length | 140 cm (extendable to 205 cm, 4-segment telescoping design) |
| Origin | Beijing, China |
| Distribution Status | Authorized Distributor |
| Brand | GTI |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GTI-600 |
| Instrument Type | Vane Anemometer |
| Wind Speed Range (FV100) | 0.30–35 m/s |
| Wind Speed Range (FV70) | 0.10–35 m/s |
| Wind Speed Range (FV14) | 0.80–25 m/s |
| Wind Speed Accuracy | ±3% ±0.1 m/s (low range), ±1% ±0.3 m/s (high range) |
| Temperature Range | 0–60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Wind Speed Resolution | 0.01 m/s |
| Data Storage Capacity | 10,000 records |
| Power Supply | 4 × AA batteries or optional AC adapter |
| Operating Temperature | 0–60 °C |
| Storage Temperature | −20–60 °C |
| Weight | ~600 g |
| Brand | GTI |
|---|---|
| Model | GTI600 |
| Instrument Type | Vane Anemometer |
| Sensor Compatibility | FV14 / FV70 / FV100 interchangeable vane probes |
| Wind Speed Range | 0.10–35 m/s (varies by probe) |
| Accuracy | ±3% ±0.1 m/s (low range), ±1% ±0.3 m/s (high range) |
| Resolution | 0.01 m/s |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Resolution | 0.1 °C |
| Data Storage | 10,000 records |
| Power | 4× AA batteries or AC adapter |
| Operating Temp | 0–60 °C |
| Storage Temp | −20–60 °C |
| Weight | ~600 g |
| Brand | GTI |
|---|---|
| Origin | Liaoning, China |
| Instrument Type | Propeller Anemometer |
| Model | GTI600 |
| Wind Speed Range (FV100) | 0.30–35 m/s |
| Wind Speed Range (FV70) | 0.10–35 m/s |
| Wind Speed Range (FV14) | 0.80–25 m/s |
| Velocity Accuracy | ±3% of reading ±0.1 m/s (low range), ±1% of reading ±0.3 m/s (high range) |
| Velocity Resolution | 0.01 m/s |
| Temperature Range | 0–60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Data Storage Capacity | 10,000 readings |
| Power Supply | 4 × AA batteries or optional AC adapter |
| Operating Temperature | 0–60 °C |
| Storage Temperature | −20–60 °C |
| Weight | ~600 g |
| Brand | GTI |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GTI600 |
| Instrument Type | Vane Anemometer |
| Wind Speed Range (FV100) | 0.30–35 m/s |
| Wind Speed Range (FV70) | 0.10–35 m/s |
| Wind Speed Range (FV14) | 0.80–25 m/s |
| Accuracy | ±3% ±0.1 m/s (low range), ±1% ±0.3 m/s (high range) |
| Wind Speed Resolution | 0.01 m/s |
| Temperature Range | 0–60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Data Storage Capacity | 10,000 records |
| Power Supply | 4 × AA batteries or AC adapter |
| Operating Temperature | 0–60 °C |
| Storage Temperature | −20–60 °C |
| Weight | ~600 g |
| Brand | GTI |
|---|---|
| Model | GTI600 |
| Instrument Type | Vane Anemometer |
| Wind Speed Range (FV100) | 0.30–35 m/s |
| Wind Speed Range (FV70) | 0.10–35 m/s |
| Wind Speed Range (FV14) | 0.80–25 m/s |
| Accuracy | ±3% ±0.1 m/s (low range), ±1% ±0.3 m/s (high range) |
| Temperature Range | 0–60 °C |
| Temperature Accuracy | ±0.5 °C |
| Resolution | 0.01 m/s (wind), 0.1 °C (temp) |
| Data Storage | 10,000 records |
| Power | 4×AA batteries or AC adapter |
| Operating Temperature | 0–60 °C |
| Weight | ~600 g |
| Key | Brand: GTI |
|---|---|
| Model | X5605 |
| Type | DC suction-type wind tunnel |
| Airspeed Range | 1–30 m/s |
| Test Section Dimensions | 230 mm (L) × φ120 mm (ID) |
| Test Port Diameter | φ2–20 mm |
| Overall Dimensions | 1002 × 237 × 319 mm |
| Power Supply | AC 220 V, 50 Hz, 450 W |
| Weight | ~20 kg |
| Flow Conditioning | Integrated honeycomb straightener |
| Visibility | Transparent test section |
| Compliance | Designed for ISO/IEC 17025-aligned calibration workflows and ASTM D2655-22 (Standard Practice for Calibration of Anemometers) |
| Brand | GTI |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | X5605 |
| Power Supply | AC 220 V, 50 Hz, 450 W |
| Weight | ~20 kg |
| Test Section Dimensions | 230 mm × φ120 mm (ID) |
| Test Port Diameter Range | φ2–φ20 mm |
| External Dimensions | 1002 × 237 × 319 mm |
| Air Velocity Range | 1–30 m/s |
| Flow Type | Direct-current suction-type |
| Flow Conditioning | Integrated honeycomb flow straightener |
| Visual Test Section | Transparent acrylic walls |
| Brand | GTI |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | X5605 |
| Price | USD 2,750 (FOB) |
| Wind Speed Range | 1–30 m/s |
| Tunnel Type | DC Suction-Type |
| Test Section Dimensions | 230 mm (L) × φ120 mm (ID) |
| Test Port Diameter | φ2–20 mm |
| Overall Dimensions | 1002 × 237 × 319 mm (L×W×H) |
| Power Supply | AC 220 V, 50 Hz, 450 W |
| Weight | ~20 kg |
| Brand | GTI |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | X5605 |
| Power Supply | AC 220 V, 50 Hz, 450 W |
| Weight | ~20 kg |
| Test Section Dimensions | 230 mm (L) × φ120 mm (ID) |
| Test Port Diameter | φ2–20 mm |
| Wind Speed Range | 1–30 m/s |
| Tunnel Type | DC suction-type |
| Flow Uniformity | Enhanced by internal honeycomb flow straightener |
| External Dimensions | 1002 × 237 × 319 mm |
| Brand | GTI |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GTI X5605 |
| Air Velocity Range | 1–30 m/s |
| Wind Tunnel Type | DC Suction-Type |
| Test Section Dimensions | 230 mm (L) × φ120 mm (ID) |
| Test Port Diameter | φ2–20 mm |
| Overall Dimensions | 1002 × 237 × 319 mm |
| Power Supply | AC 220 V, 50 Hz, 450 W |
| Weight | ~20 kg |
| Brand | GTI |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | X5606 Series |
| Wind Speed Range | 0.1–30 m/s |
| Tunnel Type | Closed-loop, DC, Low-speed Wind Tunnel |
| Test Section Dimensions | 300 mm × 300 mm (W × H) |
| Overall Dimensions | ~3000 mm × 800 mm × 1600 mm (L × W × H) |
| Flow Uniformity Coefficient | ≤1% |
| Flow Stability Coefficient | ≤0.5% |
| Motor Power | 2 kW |
| Power Supply | 220 V, 50 Hz |
| Control Mode | Manual (X5606), Manual (X5606M), Automatic (X5606A) |
| Standard Equipment | Included in X5606M & X5606A (temperature/humidity sensor, barometric pressure sensor, thermal anemometer, electronic micro-differential pressure gauge, pitot tube) |
| Software System | Included in X5606A (display, industrial PC, data acquisition module, operator console, calibration software) |
| Total Weight | ~200 kg |
| Brand | GW |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WE550 |
| Price | Upon Request |
| Type | Three-Cup Anemometer |
| Threshold Wind Speed | <1.35 m/s |
| Output Signal | 4–20 mA (2-wire loop-powered) |
| Wind Speed Range | 0–50 m/s |
| Accuracy | ±0.09 m/s (within 4.9–24.6 m/s range) |
| Operating Voltage | 10–36 VDC |
| Warm-up Time | ≥3 s |
| Operating Temperature | −40 °C to +55 °C |
| Dimensions | Ø180 mm × 216 mm (H) |
| Weight | 0.5 kg |
| Standard Configuration | WE550 sensor unit, printed user manual |
| Key Construction Features | Marine-grade cable, fully potted electronics, 1-inch NPT mounting thread |
| Brand | GW |
|---|---|
| Origin | USA |
| Model | WE570 |
| Output | 4–20 mA |
| Wind Direction Range | 0–360° |
| Sensitivity | ≥1 m/s |
| Accuracy | ±1° |
| Operating Voltage | 10–36 VDC |
| Warm-up Time | ≥3 s |
| Operating Temperature | −40 to +55 °C |
| Diameter × Height | 21.5 cm × 26.7 cm |
| Weight | 0.5 kg |
| Enclosure | Fully Sealed Electronics |
| Mounting | 1" NPT Threaded Fitting |
| Cable | Marine-Grade Shielded Cable |
| Standard Package | WE570 Sensor Unit + User Manual |
| Brand | HJ |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | HJ Purification Equipment Co., Ltd. |
| Model | FLY-1 |
| Instrument Type | Pitot Tube Anemometer |
| Flow Range | 100–3500 m³/h |
| Resolution | 100–3500 m³/h |
| Accuracy | ±5% FS |
| Operating Temperature | 5–35 °C |
| Operating Humidity | 15–70% RH |
| Internal Battery Life | 30 h |
| Data Retention After Power Loss | 4 h |
| Pressure Drop Across Probe | ≤5 Pa |
| Memory Capacity | 1000 airflow records |
| Display | LCD with print interface |
| Standard Accessories | 570×570 mm & 830×830 mm flow hoods, 7.2 V rechargeable battery + charger, external thermal printer, height-adjustable tripod (max extended height: 3.1 m including instrument) |
| Optional | PC-based data analysis software |
| Brand | HJ Purification |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | FLY-1B |
| Instrument Category | Air Flow Meter (Pitot-Static Type) |
| Operating Temperature | 5–35°C |
| Operating Relative Humidity | 15–70% RH |
| Battery Life | ≥30 h (internal rechargeable 7.2 V Li-ion) |
| Data Storage Capacity | 1000风口 records |
| Pressure Drop Across Probe | ≤5 Pa |
| Accuracy | ±5% of Full Scale (FS) |
| Flow Range | 100–3500 m³/h |
| Standard Accessories | 570×570 mm & 830×830 mm flow hoods, adjustable tripod (max height 3.1 m), Bluetooth thermal printer (built-in Li-ion battery), PC analysis software, IR remote controller |
| Compliance | Calibrated per 0.5-class wind tunnel standard (per GB/T 2624 & JJG 875) |
| Brand | HJ |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ZRQF-F30J |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.05–30.0 m/s |
| Accuracy | ±(4% of reading + 0.1) m/s for 0.05–5.00 m/s |
| Operating Temperature | 0–40 °C |
| Operating Relative Humidity | <90% RH |
| Temperature Measurement Range | 0–40 °C |
| Temperature Accuracy | ±0.5 °C |
| Relative Humidity Range | 0–100% RH |
| RH Accuracy | ±5% RH |
| Power Supply | 4 × AA batteries (6 V DC) |
| Probe Length | 0.62 m (sensor rod), 3 m cable |
| Probe Diameter | Φ11 mm |
| Dimensions (W×D×H) | 187 × 84 × 46 mm |
| Weight | >1 kg |
| Brand | Kanomax |
|---|---|
| Origin | China (Liaoning) |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Power Supply | AC 100–240 V / DC 12–24 V |
| Dimensions (Main Unit) | 220 × 130 × 40 mm |
| Weight (Main Unit) | 0.6 kg |
| Channel Capacity | 12 simultaneous probes |
| Communication | USB Micro-B, RS-485 serial interface |
| Software Compatibility | Windows 10, tri-lingual UI (English, Japanese, Chinese) |
| Max Expandable Channels | 144 (via up to 12 × MODEL 1592-0C analog output modules) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Channel Capacity | 12 simultaneous analog input channels |
| Probe Compatibility | 15 interchangeable probe models |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Unit Dimensions | 220 × 130 × 40 mm |
| Unit Weight | 0.6 kg |
| Communication | USB Micro-B, RS-485 serial (via standardized cable), LAN (optional via software interface) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 1580-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Channels | 12 simultaneous |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (Unit) | 220 × 130 × 40 mm |
| Weight (Unit) | 0.6 kg |
| Communication | USB Micro-B, RS-485 serial |
| Software | Windows 10-compatible, tri-lingual (EN/JP/CN), real-time 144-channel data logging capability |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 1580-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Channels | 12 simultaneous inputs |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (Unit) | 220 × 130 × 40 mm |
| Weight (Unit) | 0.6 kg |
| Communication | USB Micro-B, RS-485 serial interface |
| Compliance | CE, RoHS, JIS B 7951 (thermal anemometry), ISO 14644-3 (cleanroom monitoring support) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer-Based Environmental Data Acquisition System |
| Resolution | 0.01 m/s (wind speed) |
| Measurement Range | Configurable per probe (0.01–50.0 m/s wind speed, 0–120 °C temperature, 5–95% RH humidity) |
| Accuracy | ±2% or ±0.02 m/s (wind), ±0.5 °C (temperature), ±3% RH (5–80% RH), ±5% RH (80–90% RH) |
| Operating Temperature | 5–40 °C |
| Storage Temperature | −10–60 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Display | 7-inch color LCD touchscreen |
| Data Storage | 8 GB internal memory (24,500 measurements per module) |
| Communication | USB 2.0, LAN (TCP/IP), RS-485 serial |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Max Channels | 144 (12 modules × 12 probes each) |
| Probe Compatibility | 15 interchangeable thermal anemometer and thermo-hygrometric probes |
| Analog Output | 12-channel module supports 0–5 V (1 kΩ) or 4–20 mA (250 Ω) per channel |
| Software | Windows 10-compatible, tri-lingual (English/Japanese/Chinese), real-time charting, CSV export, configurable averaging/min/max/statistics |
| Brand | Kanomax |
|---|---|
| Origin | China (Liaoning) |
| Model | 1590-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s (dependent on probe selection) |
| Accuracy | ±2% or ±0.02 m/s (whichever is greater), ±3% for selected probes |
| Operating Temperature | 5–40 °C |
| Storage Temperature | −10–60 °C |
| Relative Humidity | 0–85% RH (operating, non-condensing), 0–90% RH (storage, non-condensing) |
| Display | 7-inch color LCD touchscreen |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (main unit) | 220 × 130 × 40 mm |
| Weight | 0.6 kg |
| Data Storage | 8 GB internal memory (up to 24,500 measurements per module) |
| Communication | USB Type-A (for storage), RS-485 serial (probe interface), LAN (optional via software) |
| Software | Windows 10-compatible, multilingual (English, Chinese, Japanese) |
| Max Channels | 144 (12 modules × 12 probes each) |
| Probe Compatibility | 15 interchangeable thermal anemometer probes, including directional/non-directional, standard/high-temperature (up to 120 °C), and ultra-compact variants |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer-Based Environmental Monitoring System |
| Model | 1590-0C |
| Resolution | 0.01 m/s |
| Measurement Range | Configurable per probe (0.01–50.0 m/s wind speed) |
| Accuracy | ±2% or ±0.02 m/s (whichever is greater), ±0.5°C temperature, ±3% RH (5–80% RH) |
| Operating Temperature | 5–40°C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Display | 7-inch color LCD touchscreen |
| Data Storage | 8 GB internal memory (24,500 measurements per unit) |
| Communication | USB 2.0, LAN (RJ45), serial interface |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (Unit) | 220 × 130 × 40 mm |
| Weight | 0.6 kg |
| Compliance | Designed for ISO 14644-1/3, EU GMP Annex 1, USP <1116>, and FDA 21 CFR Part 11-ready data integrity workflows |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s (dependent on probe selection) |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater), ±3% for specific probe models |
| Operating Temperature | 0–60 °C (probe-dependent up to 120 °C) |
| Operating Humidity | 0–90 %RH (non-condensing) |
| Display | 7-inch color LCD touchscreen |
| Data Storage | 8 GB internal memory (24,500 measurements per module) |
| Communication | USB, LAN |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Max Channels | 144 (12 modules × 12 probes) |
| Probe Compatibility | 15 interchangeable thermal anemometer probes |
| Analog Output | 0–5 V / 4–20 mA per channel (configurable per channel) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 20–85% RH |
| Temperature Compensation | Integrated circuit for enhanced accuracy within 10–40 °C |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 20–85% RH |
| Temperature Compensation | Active compensation circuit optimized for 10–40 °C range |
| Sensor Element | Platinum-wire hot-wire anemometer |