Anemometer Air Flow Meter
Filter
Showing 271–300 of 390 results
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6715 |
| Instrument Type | Pitot Tube-Based Air Flow Hood |
| Measurement Range | 40–4300 m³/h |
| Accuracy | ±3% of reading ±10 m³/h |
| Operating Temperature | 0–50 °C |
| Operating Humidity | 10–90% RH |
| Display | 3.5-inch color LCD (rotatable ±30°) |
| Data Storage | 8,000 sets |
| Power Supply | 4 × AA batteries (9 h typical) or DC 5 V adapter |
| Weight | 3.6 kg |
| Standard Hood Size | 610 × 610 mm |
| Bluetooth Connectivity | Yes |
| Backpressure Compensation | Yes |
| Compliant With | ISO 16813, ASHRAE 111, ASTM D5482, EN 12599 |
| Key | Brand: Kanomax |
|---|---|
| Origin | Japan |
| Model | 6720 |
| Airflow Range | 40–4300 m³/h |
| Accuracy | ±3% of reading ±8 m³/h |
| Air Velocity Range (with Pitot tube) | 0.15–40 m/s |
| Air Velocity Range (with velocity matrix) | 0.15–15 m/s |
| Velocity Accuracy | ±3% of reading ±0.05 m/s |
| Differential Pressure Range | −2500 to +2500 Pa |
| DP Accuracy | ±1.5% of reading ±0.25 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Humidity Range | 0–100 %RH |
| RH Accuracy | ±3 %RH (10–90 %RH) |
| Operating Environment | 0–60 °C, 0–100 %RH |
| Display | 4.3-inch full-color touchscreen LCD |
| Data Storage | 8,000 measurements (host), 10,000 (via Kanomax Mobile App) |
| Power | 4 × AA batteries (≈9 h), or DC 5 V adapter |
| Weight | 3.6 kg |
| Standard Hood Size | 610 × 610 mm |
| Optional Hood Sizes | 610×1220 mm, 305×1220 mm, 500×500 mm, 915×915 mm, 915×610 mm, 800×1400 mm |
| Key Functions | Backpressure compensation, airflow direction detection (supply/exhaust), barometric pressure correction, real-time Bluetooth data transmission, USB export, on-device clock & battery indicator |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6720 |
| Air Flow Range | 40–4300 m³/h |
| Accuracy | ±3% of reading ±8 m³/h |
| Air Velocity Range (with Pitot tube) | 0.15–40 m/s |
| Air Velocity Range (with Matrix Sensor) | 0.15–15 m/s |
| Velocity Accuracy | ±3% of reading ±0.05 m/s |
| Differential Pressure Range | −2500 to +2500 Pa |
| DP Accuracy | ±1.5% of reading ±0.25 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Humidity Range | 0–100 %RH |
| RH Accuracy | ±3 %RH (10–90 %RH) |
| Operating Environment | 0–60 °C, 0–100 %RH |
| Display | 4.3-inch full-color touchscreen LCD |
| Data Storage | 8,000 measurements (instrument), 10,000 (mobile app) |
| Power | 4 × AA batteries (≈9 h), DC 5 V adapter |
| Weight | 3.6 kg |
| Standard Hood Size | 610 × 610 mm |
| Optional Hood Sizes | 610×1220 mm, 305×1220 mm, 500×500 mm, 915×915 mm, 915×610 mm, 800×1400 mm |
| Key Functions | Backpressure compensation, inlet/exhaust mode detection, atmospheric pressure & temperature correction, 16-point differential pressure sampling, Bluetooth 5.0, USB data export, real-time thermal printing |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6720 |
| Air Flow Range | 40–4300 m³/h |
| Accuracy | ±3% of reading ±8 m³/h |
| Air Velocity Range (with Pitot Tube) | 0.15–40 m/s |
| Air Velocity Range (with Matrix Sensor) | 0.15–15 m/s |
| Velocity Accuracy | ±3% of reading ±0.05 m/s |
| Differential Pressure Range | −2500 to +2500 Pa |
| DP Accuracy | ±1.5% of reading ±0.25 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Humidity Range | 0–100 %RH |
| RH Accuracy | ±3 %RH (10–90 %RH) |
| Operating Environment | 0–60 °C, 0–100 %RH |
| Display | 4.3-inch full-color touchscreen LCD |
| Data Storage | 8,000 measurements (instrument), 10,000 (mobile app) |
| Power | 4 × AA batteries (≈9 h), DC 5 V adapter |
| Weight | 3.6 kg |
| Standard Hood Size | 610 × 610 mm |
| Optional Hood Sizes | 610×1220, 305×1220, 500×500, 915×915, 915×610, 800×1400 mm |
| Key Functions | Backpressure compensation, inlet/exhaust mode detection, atmospheric pressure & temperature correction, 16-point differential pressure sensing grid, Bluetooth 4.2, USB data export, real-time thermal printing support |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6720 |
| Air Flow Range | 40–4300 m³/h |
| Accuracy | ±3% of reading ±8 m³/h |
| Air Velocity Range (with Pitot tube) | 0.15–40 m/s |
| Air Velocity Range (with matrix sensor) | 0.15–15 m/s |
| Velocity Accuracy | ±3% of reading ±0.05 m/s |
| Differential Pressure Range | −2500 to +2500 Pa |
| DP Accuracy | ±1.5% of reading ±0.25 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Humidity Range | 0–100 %RH |
| RH Accuracy | ±3 %RH (10–90 %RH) |
| Operating Environment | 0–60 °C, 0–100 %RH |
| Display | 4.3-inch full-color touchscreen LCD |
| Data Storage | 8,000 measurements (instrument), 10,000 (mobile app) |
| Power | 4 × AA batteries (≈9 h), DC 5 V adapter |
| Weight | 3.6 kg |
| Standard Hood Size | 610 × 610 mm |
| Optional Hood Sizes | 610 × 1220 mm, 305 × 1220 mm, 500 × 500 mm, 915 × 915 mm, 915 × 610 mm, 800 × 1400 mm |
| Key Functions | Backpressure compensation, inlet/exhaust mode detection, atmospheric pressure & temperature correction, real-time Bluetooth data transmission, USB export, on-device clock & battery indicator |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6750 |
| Resolution | 1 m³/h |
| Measurement Range | ±8–600 m³/h |
| Accuracy | ±(3% of reading + 1 m³/h) for 8–350 m³/h |
| Operating Temperature | 0–50 °C |
| Operating Humidity | 0–100 %RH |
| Display | Full-color TFT LCD with transparent viewing window |
| Connectivity | Bluetooth 4.2 (BLE) for wireless data transmission |
| Power Supply | Rechargeable Li-ion battery (up to 8 hours continuous operation) |
| Compliance | CE, RoHS, JIS B 8619 (Air Volume Measurement Instruments for HVAC Systems) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6750 |
| Air Flow Range | ±8–600 m³/h |
| Accuracy | ±(3% of reading + 1 m³/h) for 8–350 m³/h |
| Temperature Range | 0–50 °C |
| Temperature Accuracy | ±0.5 °C |
| Display | 160×80 mm color LCD |
| Data Storage | Up to 6,000 records (internal memory) |
| Communication | Bluetooth v4.0, USB output |
| Power | 4 × AA alkaline batteries or AC adapter |
| Operating Time | ~8 hours |
| Dimensions (hood) | 355×355×450 mm (W×H×D) |
| Hood Aperture | 355×355 mm |
| Weight | 1.5 kg |
| Compliance | Designed for ISO 14644-3, ISO 14644-4, IEST-RP-CC006.3, and ASHRAE 111-2020 test protocols |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6750 |
| Resolution | 1 m³/h |
| Measurement Range | ±8–600 m³/h |
| Accuracy | ±(3% of reading + 1 m³/h) for 8–350 m³/h |
| Operating Temperature | 0–50 °C |
| Operating Humidity | 0–100 %RH |
| Temperature Accuracy | ±0.5 °C |
| Display | Simultaneous real-time airflow and temperature readout |
| Units | m³/h, CFM, °C |
| Data Storage | Up to 6,000 records (internal memory) |
| Communication | Bluetooth 4.0, USB output |
| Power | 4 × AA batteries or AC adapter |
| Battery Life | Approx. 8 hours continuous operation |
| Dimensions (hood) | 355 × 355 × 450 mm (W×H×D) |
| Hood Aperture | 355 × 355 mm |
| Display Module | 160 × 80 × 45 mm |
| Weight | 1.5 kg |
| Construction | Fiberglass support frame, transparent viewing window for visual alignment verification |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6821 / 6823 |
| Instrument Type | Vane Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.2–40.0 m/s |
| Accuracy | ±3% of reading or ±0.1 m/s (whichever is greater) |
| Temperature Range | –20 to +100 °C |
| Temperature Accuracy | ±0.3 °C + 0.2% of reading |
| Air Volume Range | 0–9,999 CFM |
| Probe Diameter | 70 mm |
| Power Supply | 3 × AA batteries |
| Dimensions | 81 × 165 × 38 mm |
| Weight | 1750 g (including batteries) |
| Brand | Kanomax |
|---|---|
| Model | 6822 |
| Type | Vane (Propeller) Anemometer |
| Measurement Range | 0.2–20.0 m/s |
| Resolution | 0.01 m/s |
| Accuracy | ±3% of reading or ±0.1 m/s (whichever is greater) |
| Operating Temperature | −20 to +100 °C |
| Operating Humidity | 5.0–95.0 %RH |
| Probe Diameter | 70 mm |
| Power Supply | 3 × AA batteries |
| Battery Life | Approx. 150 hours |
| Dimensions (W×H×D) | 81 × 165 × 38 mm |
| Weight | 175 g (including batteries) |
| Air Volume Calculation | Yes (user-input duct geometry) |
| Display | Backlit LCD |
| Data Hold & Min/Max/Avg Functions | Yes |
| Brand | Kanomax |
|---|---|
| Type | Vane Anemometer |
| Measurement Range | 0.2–20.0 m/s |
| Resolution | 0.01 m/s |
| Accuracy | ±3% of reading or ±0.1 m/s (whichever is greater) |
| Temperature Range | −20 to +100 °C |
| Temperature Accuracy | ±1.0 °C |
| Humidity Range (Model 6824 only) | 5.0–95.0 %RH |
| Humidity Accuracy (Model 6824 only) | ±2.0 %RH |
| Air Volume Calculation | 0–9,999 CFM |
| Probe Diameter | 70 mm |
| Power Supply | 3 × AA batteries |
| Battery Life | Approx. 150 hours |
| Dimensions (W×H×D) | 81 × 165 × 38 mm |
| Weight | 175 g (including batteries) |
| Operating Environment | −20 to +100 °C, 5–95 %RH (non-condensing) |
| Brand | Kanomax |
|---|---|
| Model | 6822 / 6824 |
| Type | Vane Anemometer |
| Resolution | 0.01 m/s |
| Velocity Range | 0.2–20.0 m/s |
| Accuracy | ±3% of reading or ±0.1 m/s (whichever is greater) |
| Temperature Range | –20 to +100 °C |
| Temperature Accuracy | ±1.0 °C |
| Humidity Range (6824 only) | 5.0–95.0 %RH |
| Humidity Accuracy (6824 only) | ±2.0 %RH |
| Air Volume Range | 0–9,999 CFM |
| Probe Diameter | 70 mm |
| Power | 3 × AA alkaline batteries |
| Battery Life | ~150 hours |
| Dimensions | 81(W) × 165(H) × 38(D) mm |
| Weight | 175 g (including batteries) |
| Compliance | Designed for ISO 14644-3, ISO 14644-1 cleanroom classification, ASTM D1896, and HVAC commissioning per ASHRAE Guideline 1 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Model | 6822 / 6824 |
| Instrument Type | Vane Anemometer |
| Velocity Range | 0.2–20.0 m/s |
| Accuracy | ±3% of reading or ±0.1 m/s (whichever is greater) |
| Temperature Range | −20–100 °C |
| Temperature Accuracy | ±1.0 °C |
| Airflow Range | 0–9,999 CFM |
| Probe Diameter | 70 mm |
| Power Source | Alkaline batteries |
| Battery Life | ~150 hours |
| Dimensions (W×H×D) | 81 × 165 × 38 mm |
| Weight | 175 g (including batteries) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6824 |
| Instrument Type | Vane Anemometer |
| Velocity Range | 0.2–20.0 m/s |
| Accuracy | ±3% of reading or ±0.1 m/s (whichever is greater) |
| Temperature Range | −20 to +100 °C |
| Temperature Accuracy | ±1.0 °C |
| Air Volume Range | 0–9,999 CFM |
| Probe Diameter | 70 mm |
| Power Source | Alkaline batteries |
| Battery Life | Approx. 150 hours |
| Dimensions (W×H×D) | 81 × 165 × 38 mm |
| Weight | 175 g (including batteries) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Display | 7-inch color LCD touchscreen |
| Max Channels | 144 (12 modules × 12 probes/module) |
| Power Supply | AC 100–240 V / DC 12–24 V |
| Data Storage | 8 GB internal memory (24,500 measurements per module) |
| Communication | USB / LAN |
| Output Options | 0–5 V / 4–20 mA (via Model 1592-0C module) |
| Compliance | CE-marked |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Dependent on Interchangeable Probe Model |
| Accuracy | ±2% of Reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | Up to 20,000 Records |
| Probe Compatibility | 8 Standard KANOMAX Thermal Probes (e.g., KA3200, KA3300, KA3400 Series) |
| Built-in Calculations | Volumetric Air Flow (m³/h, CFM), Average/Min/Max Statistics, Hold Function |
| Input Parameters | Custom Duct Geometry (Rectangular, Circular, Oval) with Dimension Entry |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Model | 1580-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Weight | 0.6 kg |
| Dimensions | 220 × 130 × 40 mm (W × D × H) |
| Power Supply | AC 100–240 V / DC 12–24 V |
| Communication | USB Micro-B, RS-485 serial interface |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 1590-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Probe-Dependent (0.01–50.0 m/s) |
| Accuracy | ±2% or ±0.02 m/s (whichever greater), ±3% for select probes |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 0–90 %RH (non-condensing) |
| Display | 7-inch color TFT touchscreen |
| Data Storage | 8 GB internal memory (24,500 measurements per module) |
| Communication | USB 2.0, LAN (RJ45), serial interface |
| Power Supply | AC 100–240 V / DC 12–24 V |
| Dimensions (H×W×D) | 40 × 220 × 130 mm |
| Weight | 0.6 kg |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible operation |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer-Based Environmental Monitoring System |
| Resolution | 0.01 m/s |
| Measurement Range | Configurable per probe (0.01–50.0 m/s) |
| Accuracy | ±2% or ±0.02 m/s (whichever greater), ±0.5 °C for temperature, ±3–5% RH (5–90% RH) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Display | 7-inch color LCD touchscreen |
| Data Storage | 8 GB internal memory (24,500 measurements per channel) |
| Communication | USB 2.0, LAN (TCP/IP), RS-485 serial |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (Unit) | 220 × 130 × 40 mm |
| Weight | 0.6 kg |
| Max Channel Capacity | 144 simultaneous channels (via 12 × MODEL 1591-0C modules, 12 probes each) |
| Probe Compatibility | 15 interchangeable thermal anemometer probes (directional/non-directional, standard/high-temp, mini-size options) |
| Analog Output | MODEL 1592-0C module supports 12-channel 4–20 mA or 0–5 V output per module (scalable to 144 channels) |
| Software | Windows 10-compatible, multilingual (EN/JP/CN), real-time charting, CSV export, configurable per-probe calibration and averaging |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 1590-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | PRO 1590-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Display | 7-inch color LCD touchscreen |
| Data Storage | 8 GB internal memory (24,500 measurements per unit) |
| Communication | USB 2.0, LAN (RJ45), serial interface |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (main unit) | 220 × 130 × 40 mm |
| Weight | 0.6 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | Dependent on Interchangeable Probe (e.g., 0–30 m/s for standard hot-wire probe) |
| Accuracy | ±2% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | Up to 20,000 records |
| Probe Compatibility | 8 interchangeable probe types (hot-wire, vane, pitot tube, and specialized duct probes) |
| Built-in Calculations | Volumetric flow (m³/h, CFM) via user-defined duct geometry (rectangular, circular, oval cross-sections with dimensional input) |
| Statistical Functions | Real-time min/max/average, hold function |
| Accessories Included | 2 m probe cable, carrying case, operator manual |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature Range | −20 °C to +70 °C |
| Operating Relative Humidity Range | 2.0–98.0% RH |
| Probe Compatibility | 8 interchangeable thermal anemometry probes (hot-wire/hot-film) |
| Data Storage Capacity | Up to 20,000 measurement records |
| Built-in Calculations | Real-time air volume (m³/h or CFM) via user-defined duct geometry (rectangular, circular, oval cross-sections with dimensional input) |
| On-device Statistics | Min/Max/Avg values with hold function |
| Standard Accessories | 2 m probe cable × 1, carrying case × 1, operator manual |
| Brand | NK |
|---|---|
| Origin | USA |
| Model | Kestrel 5100 |
| Instrument Type | Vane Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0.4–60 m/s |
| Accuracy | ±3% of reading |
| Operating Temperature | −10 to 55 °C |
| Operating Humidity | 0–100% RH |
| IP Rating | IP67 |
| Data Storage Capacity | >10,000 timestamped records |
| Power Source | Two AA batteries (≈400 h typical life) |
| Wireless Connectivity | Bluetooth Smart® (via Kestrel LiNK app) |
| Dimensions | 6.5 × 7.5 × 22 cm |
| Weight | 295 g (with wind vane kit) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Range | Kestrel 1000, 2000, 2500, 3000, 3500, 4000, 4200, 4300, 4500 |
| Pricing | Available Upon Request |
| Brand | NK |
|---|---|
| Origin | USA |
| Model | 0801 |
| Instrument Type | Vane Anemometer Impeller |
| Resolution | 0.1 m/s |
| Measurement Range | 0–60 m/s |
| Accuracy | ±2% of reading |
| Operating Temperature | −55°C to +70°C |
| Operating Humidity | 0–100% RH |
| Compliance | Designed for use with Kestrel Series handheld environmental meters (e.g., Kestrel 4000, 5000, 5500, DROP series) |
| Brand | Lambrecht |
|---|---|
| Origin | Germany |
| Model | 002 |
| Measurement Range (Wind Speed) | 0.3–75 m/s |
| Accuracy (Wind Speed) | ±0.3 m/s (≤10 m/s), ±1% FS (10–50 m/s) |
| Resolution (Wind Speed) | < 0.1 m/s |
| Starting Threshold (Wind Speed) | < 0.3 m/s |
| Measurement Range (Wind Direction) | 0–360° |
| Resolution (Wind Direction) | 2.5° |
| Output Signals | 4–20 mA (0–360°), 3 × 0–10 VDC (analog, electrical wave format) |
| Starting Threshold (Wind Direction) | < 0.7 m/s |
| Data Storage | Integrated SD card supporting ≥1 year of continuous logging |
| Power Supply | Included dedicated DC power system |
| Connectivity | Pre-wired industrial-grade cable assembly |
| Brand | Lambrecht |
|---|---|
| Origin | Germany |
| Model | 123-9 |
| Measurement Range | 0–360° |
| Resolution | 2.5° |
| Output Signals | 4–20 mA (0–360°), 3 × 0–10 VDC (analog waveform) |
| Starting Wind Speed | < 0.7 m/s |
| Supply Voltage | 24 VDC (10–30 VDC) |
| Housing | Anodized Marine-Grade Aluminum |
| Cable | 12 m Pre-terminated Connectable Cable |
| Compliance | CE, RoHS, EN 61326-1 (EMC for Industrial Environments) |
| Brand | Lambrecht |
|---|---|
| Model | 578 |
| Origin | Germany |
| Sensor Type | Ultrasonic Anemometer |
| Operating Temperature | -40 to +65 °C |
| Storage Temperature | -45 to +70 °C |
| Power Consumption | Avg. 0.14 mA, Peak 30 mA (external supply) |
| Battery | 3 V Lithium Cell |
| Battery Life | 8 months (no solar), 2 years (with 0.5 W solar panel) |
| Compliance | CE, RoHS, IP65 enclosure rating |
| Data Logging | Internal SD card storage with timestamped binary/CSV export |
| Communication | RS-485 (Modbus RTU), optional USB or Bluetooth interface |
| Brand | Lambrecht |
|---|---|
| Origin | Germany |
| Model | 346 |
| Sensor Type | Ultrasonic (3D wind vector) |
| Display | Integrated handheld LCD unit |
| Data Logging | Internal SD card storage |
| Power Supply | Rechargeable Li-ion battery (≥12 h continuous operation) |
| Compliance | IP67 enclosure rating |
| Operating Temperature | −30 °C to +50 °C |
| Communication Interface | USB 2.0, RS-232 optional |
| Software | Lambrecht WindLog Pro v4.x (Windows/macOS) with GLP-compliant audit trail and CSV/NetCDF export |