- All
- Favorite
- Popular
- Most rated
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LC3200S Series |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical HPLC |
| Maximum Operating Pressure | 45 MPa |
| Wavelength Range (UV/Vis Detector) | 188–900 nm |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PA2000 |
| Instrument Type | Portable |
| Detection Principle | Catalytic Oxidation + Flame Ionization Detection (FID) |
| Regulatory Compliance | HJ 1012–2018 |
| Detection Limit | Sub-ppb (NMHC) |
| Analysis Cycle | As low as 5 seconds |
| Operating Temperature | Full-path high-temperature heating (≥180 °C) |
| Methane Separation Method | High-efficiency catalytic oxidation (≥98% conversion efficiency) |
| Catalyst Lifetime | ≥3 years |
| Oxygen Measurement | Integrated paramagnetic/O₂ sensor |
| Weight | ~13 kg |
| Carrier Gas | Not required |
| Combustion Air | Built-in compressor — no external air supply needed |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Country of Origin | China |
| Model | AQ7100 |
| Pricing | Available upon Request |
| Measured Parameters | SO₂, NO₂, CO, O₃, PM₂.₅, PM₁₀, TVOC, Temperature, Relative Humidity |
| Brand | Wayeal |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model Series | GC6000 |
| Temperature Control Range | +4 °C above ambient to 450 °C |
| Maximum Ramp Rate | 60 °C/min |
| Carrier Gas Flow Control | Electronic Flow Control (EFC) |
| Injector Maximum Operating Temperature | 400 °C |
| Detector Options | FID6000 (standard), ECD (optional) |
| Autosampler Compatibility | ALS6000 (optional) |
| Air Purification System | Wayeal-built (optional) |
| MS Interface | 预留接口 (MS coupling port available upon request) |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TQ9200 |
| Instrument Type | Triple Quadrupole (Tandem QqQ) Mass Spectrometer |
| Application Scope | Universal (Broad-Spectrum Quantitative & Qualitative Analysis) |
| LC Component | WAYEAL LC3600 Ultra-High-Performance Liquid Chromatograph |
| Ionization Source | Electrospray Ionization (ESI), Standard Configuration |
| Vacuum Interface | High-Durability Conical Interface with Active Desolvation |
| Detection Mode | Multiple Reaction Monitoring (MRM), Selected Reaction Monitoring (SRM), Full Scan, Product Ion Scan, Precursor Ion Scan, Neutral Loss Scan |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LD1200A |
| Pricing | Upon Request |
| Measurement Principle | Laser Forward Light Scattering |
| Safety Rating | Non-Explosive |
| Measurement Range | 0–15 mg/m³ |
| Resolution | 0.1 mg/m³ |
| Accuracy | ±10% of reading |
| Relative Error | ±2% |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Model | IC6500 |
| Pump Pressure Rating | 42 MPa |
| Operating Temperature Range | 5 °C to 70 °C |
| Flow Path Material | Full PEEK |
| Detector Configuration | Dual Conductivity Detector |
| Eluent Generation | Integrated On-Line Electrolytic Eluent Generator |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC6100 |
| Application Scope | General-Purpose |
| Control Architecture | Dual-Core Mainboard (Quad-Core Application Processor + Dual-Core Co-Processor) |
| Temperature Control | PID with Auto-Tuning & Environmental Compensation |
| EPC System | High-Stability Electronic Pressure Control |
| Detectors Supported | FID (1000 Hz Sampling Rate, 0.5 ms Minimum Peak Width), ECD (Low-Radiation Microcell), MS (Integrated with WAYEAL Mass Spectrometer) |
| Software Platform | SmartLab CDS Workstation with H.B.C-ApexFinder & SmartPeak Algorithms |
| Connectivity | Web-Based UI, Touchscreen (10.1" Capacitive), Remote Access via Browser |
| Compliance Features | Audit Trail, User Permission Levels, Electronic Signatures (FDA 21 CFR Part 11 Ready), GLP/GMP Data Integrity Support |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | Modular Differential Pressure Airtightness Leak Tester |
| Pricing | Upon Request |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FLD |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 200–650 nm |
| Detection Mode | Fluorescence |
| Light Source | Mercury-Xenon Lamp |
| Display Interface | Touchscreen LCD |
| Data Output | Dual Analog Channels |
| Communication Interfaces | RS232, Ethernet |
| Compatible System | High-Performance Liquid Chromatography (HPLC) |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | ZH600-X Multi-Station Hermeticity Leak Detector |
| Pricing | Available Upon Request |
| Pressure Sensor Range (ZH600-X) | 10–500 kPa (mechanically regulated) |
| Sensor Accuracy | ±0.1% FS |
| Display Resolution | Adjustable to 0–4 decimal places |
| Pressure Units | kPa, MPa, kg/cm², psi, mbar, bar, Torr, mmH₂O, mmHg |
| Leak Rate Units | Pa, kPa, Pa/s, kPa/s, kPa/min, mL/s, mL/min, mL/h, L/min, L/h, SCCM |
| Programmable Test Profiles | 64 total (16 per channel across A/B/C/D channels) |
| Test Cycle Time | 0–999 s (max test duration: 1800 s) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Required Test Gas Source | Clean, dry, ≥500 kPa supply pressure, ≥100 kPa above test pressure |
| Dimensions (ZH600-X) | 431 × 187 × 460 mm |
| Weight | ~14 kg |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | AQ7800 |
| Instrument Type | Online Fixed-Station Analyzer |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Measurement Method | Direct Analysis (Non-Preconcentration Bypass Mode with Cold Trap Preconcentration Option) |
| Detection Limit | ≤1 ppbC (as Carbon) |
| Compliance | HJC-ZY84-2020 |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer | WAYEAL Instrument Co., Ltd. |
| Model | WS1801 |
| Instrument Type | Online Automatic Water Sampler |
| Sampling Method | Exceedance-triggered Retention Sampling |
| Single Sample Volume | 10 mL to 1000 mL |
| Sampling Volume Accuracy | ±7% (at 200 mL retention volume) |
| Sampling Interval | Adjustable from 1 min to 9999 min |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | SFJ-16C / SFJ-16D |
| Base Pump | Rotary Vane Vacuum Pump (SFJ-16C) / Scroll Vacuum Pump (SFJ-16D) |
| Minimum Detectable Leak Rate (Vacuum Mode) | 5.0 × 10⁻¹³ Pa·m³/s |
| Minimum Detectable Leak Rate (Sniffer Mode) | 2.5 × 10⁻⁹ Pa·m³/s |
| Maximum Allowable Test Pressure | 1800 Pa |
| Human-Machine Interface | 7-inch Color TFT LCD Touchscreen |
| Leak Port Connection | DN25 KF |
| Dimensions (W×D×H) | 475 × 714 × 1168 mm |
| Power Supply | AC 220 V (±10%), 50/60 Hz |
| Response Time | <1 s |
| Pump-Down/Startup Time | <95 s |
| Detectable Masses | m/z = 2 (H₂), 3 (³He), 4 (⁴He) |
| Ion Source | Dual Filament, Yttria-Coated Iridium, Auto-Switching |
| I/O Interfaces | RS-232, RS-485, LAN, MES Integration Ready |
| Operating Temperature | 0–40 °C |
| Display Languages | English & Chinese |
| Leak Rate Visualization | Numeric Value, Bar Graph, Real-Time Trend Curve |
| Compliance | Designed for ISO 10110-7, ASTM E1003, and JIS Z 2301 aligned workflows |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LC3600 Series |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Instrumentation |
| Wavelength Range | 188–900 nm |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WMS1800 |
| Pricing | Available upon Request |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LC3400 |
| Instrument Type | Ultra-Fast Liquid Chromatograph |
| Maximum Operating Pressure | 75 MPa |
| Application Scope | General-Purpose HPLC/UHPLC Analysis |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VM1700 |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Target Analytes | Methane (CH₄), Total Hydrocarbons (THC), Non-Methane Hydrocarbons (NMHC), and selected BTEX compounds |
| Sample Path Temperature | 175 °C (fully heated from probe to detector) |
| Compliance | Certified by China National Environmental Monitoring Centre (CNEMC) for CEMS applicability testing |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS 1200 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ≤ ±5% FS |
| Repeatability | ≤ 1% FS |
| Response Time | ≤ 90 s |
| Drift Stability | ≤ 1% FS over 7 days |
| Measured Parameters | SO₂, NOₓ (NO + NO₂), O₂, CO, CO₂, HCl, particulate matter (PM) concentration, flue gas velocity, static pressure, relative humidity, emission rate, and cumulative emissions |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WS1504 |
| Pricing | Available upon Request |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CEMS1250 |
| Instrument Type | Flue Gas Continuous Emission Monitoring System |
| Measurement Accuracy | ±2.5% FS |
| Repeatability | ±2% FS |
| Response Time | 200 s |
| Long-term Stability | ±5% FS |
| Measured Parameters | SO₂, NO, O₂, Particulate Matter (PM) Concentration, Flue Gas Temperature, Pressure, Velocity, Relative Humidity |
| Derived Outputs | Emission Rate, Total Emissions |
| Sampling Method | Direct Extraction with Cold-Dry Conditioning |
| Certified Low-Range Quantification | SO₂ & NO at 0–45 mg/m³ |
| PM Detection Principle | Laser Forward Scattering |
| PM Certified Range | 0–15 mg/m³ |
| Compliance | Meets Chinese HJ 75–2017 and HJ 76–2017 Technical Specifications for CEMS |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | WS1503 |
| Price Range | USD 7,000 – 14,000 |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | WS1505 |
| Pricing | Upon Request |
| Measurement Method | Alkaline Potassium Persulfate Digestion – UV Spectrophotometry |
| Measurement Range | 0–200.0 mg/L (expandable) |
| Accuracy | ±5% |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CEMS1200 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measured Parameters | SO₂, NOₓ (NO, NO₂), O₂ |
| Measurement Principle (O₂) | Electrochemical Sensor |
| Measurement Principle (Temperature) | PT100 or Thermocouple Sensor |
| Measurement Principle (Pressure) | Piezoresistive Pressure Transducer |
| Measurement Principle (Flow Velocity) | Pitot Tube |
| Measurement Principle (Humidity) | High-Temperature Capacitive Hygrometer |
| Sampling Method | Direct Extraction – Hot/Wet Method |
| Certified SO₂ Range | 0–70 mg/m³ |
| Certified NO Range | 0–65 mg/m³ |
| Particulate Matter Method | Laser Forward Scattering |
| Certified PM Range | 0–15 mg/m³ |
| Data Interface | Modbus RTU/TCP, OPC UA, 4–20 mA, RS-232/485 |
| Compliance Support | GB/T 16157, HJ 75–2017, HJ 76–2017, ISO 12039, EN 15267 |
Show next