| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Digtor 22 C-8 |
| Instrument Type | Benchtop Centrifuge |
| Max Speed | 3000 rpm |
| Max RCF | 2425 × g |
| Max Capacity | 4 × 100 mL (8" tubes) |
| Dimensions (W×D×H) | 540 × 650 × 400 mm |
| Heating Range | +5°C to 80°C (programmable in 1°C/1°F increments) |
| Compliance | ASTM D91, D96, D893, D1796, D2273, D2709, D2711, D4007, D5546 |
| Safety Standards | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EN 61010-2-010 |
| EU Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | R 50/250/12 |
| Instrument Type | Tube Furnace |
| Max Temperature | 1200 °C or 1300 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 6.5 kW |
| Heating Time to Max Temp | 60 min |
| Heating Method | Resistance Wire |
| Tube Outer Diameter Range | 50–120 mm |
| Electrical Supply | 1-phase or 3-phase, depending on model |
| Weight | 20–230 kg (model-dependent) |
| Compliance | EN 60519-2 (thermal protection class 2), CE-marked |
| Brand | Leman Instruments |
|---|---|
| Origin | France |
| Model | AERO50LS |
| Hydrocarbon Removal Principle | High-Temperature Catalytic Cracking |
| Output Flow Rates | 20 / 40 / 80 L/min |
| Maximum Output Pressure | 5 bar |
| Total Hydrocarbon (THC) Content | < 0.05 ppm |
| Dew Point | –60 °C (DP) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Biocen 22 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 15,000 rpm |
| Max RCF | 21,885 × g |
| Capacity | 24 × 2 mL or 12 × 5 mL |
| Dimensions (W×D×H) | 276 × 390 × 272 mm |
| Noise Level | <60 dB(A) |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EU Directives 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU, 98/79/EC |
| Brand | Analysis |
|---|---|
| Origin | Spain |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MINICEN |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed Centrifuge (10,000–30,000 rpm) |
| Function | General-Purpose Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Maximum Capacity | 12 × 1.5–2 mL |
| Maximum Speed | 15,000 rpm |
| Maximum RCF | 15,596 × g |
| Dimensions (W×D×H) | 230 × 270 × 130 mm |
| Net Weight | 5 kg |
| Display | LCD |
| Speed/RCF Increment | 100 rpm / 100 × g |
| Timer Range | 30 s – 999 min (1 s increment) |
| Noise Level | <60 dB(A) |
| Motor | Brushless DC, Maintenance-Free |
| Safety Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | Leman Instruments |
|---|---|
| Origin | Spain (designed in France, engineered with Swiss technology) |
| Model | HYDRO50LS |
| Hydrogen Generation Principle | Proton Exchange Membrane (PEM) Electrolysis |
| Output Flow Rates | 1–4 L/min (adjustable in discrete steps) |
| Maximum Output Pressure | 7 bar |
| Hydrogen Purity | >99.999% (v/v) |
| Power Consumption | 200 W |
| Display & Connectivity | Full-color touchscreen interface |
| Maintenance | Maintenance-free operation under normal laboratory conditions |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Digtor 22 Col |
| Type | Benchtop Centrifuge |
| Maximum Speed | 3000 rpm |
| Maximum RCF | 1801 × g |
| Maximum Capacity | 4 × 60 mL |
| Dimensions (W×D×H) | 540 × 650 × 400 mm |
| Noise Level | <60 dB(A) |
| Motor | Brushless Induction Motor |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EN 61010-2-010, EU Directives 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU, 98/79/EC |
| Origin | Germany |
|---|---|
| Type | Box-Type Muffle Furnace |
| Max Operating Temperature | 1400 °C / 1500 °C / 1600 °C |
| Temperature Uniformity | ±1 °C |
| Heating Element | Silicon Carbide (SiC) Rods |
| Internal Chamber Dimensions | 170 × 290 × 170 mm |
| Max Power Input | 13.0 kW |
| Ramp Time to Max Temperature | ≤45 min |
| Construction | Dual-Wall Stainless Steel Housing with Ceramic Fiber Insulation |
| Compliance | EN 60519-2 (Thermal Protection Class 2), CE Marked |
| Brand | Leman Instruments |
|---|---|
| Origin | France |
| Model | AERO60LS |
| Hydrocarbon Removal Principle | High-Temperature Catalytic Cracking |
| Output Flow Rates | 40, 80, 100, 120 L/min |
| Maximum Output Pressure | 5 bar |
| Total Hydrocarbons (HCnm) | ≤ 0.01 ppm |
| Dew Point | −70°C |
| Water Content | < 2 ppm (−70°C DP) |
| CO₂ | < 0.5 ppm |
| CO + CH₄ | < 0.03 ppm |
| NOₓ | < 2 ppb |
| O₃, SO₂, NH₃ | < 1 ppb |
| Particulates | < 0.1 µm |
| Brand | Leman Instruments |
|---|---|
| Origin | France |
| Model | AEROSTATION 50 TOC LC or RC |
| Hydrocarbon Removal Principle | High-Temperature Catalytic Cracking |
| Output Flow Rate | 1.5–3 L/min |
| Maximum Output Pressure | 5 bar |
| Total Hydrocarbon (THC) Content | <0.05 ppm |
| Dew Point | −60 °C (DP) |
| CO₂ Content | <1 ppm |
| Display & Connectivity | Full-color touchscreen interface |
| Brand | Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HCV2000 |
| Instrument Category | Other Vacuum Pumps |
| Product Type | Oil-Free Vacuum Pump |
| Pumping Speed | 200 L/min |
| Ultimate Vacuum | –92 kPa |
| External Dimensions | 244 × 128 × 205 mm (L × W × H) |
| Weight | 9 kg |
| Motor Power | 500 W |
| Rated Voltage/Frequency | 220 V / 50 Hz (customizable) |
| Insulation Class | B |
| Thermal Protector | Auto-resetting at 130 ± 5 °C |
| Operating Ambient Temperature | 5–40 °C |
| Inlet/Outlet Port Thread | G1/4″ NPT |
| Hose Connection Diameter | 6 mm × 4 mm |
| Brand | Analysis |
|---|---|
| Origin | Spain |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | CONSUL22 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 100–14,300 rpm |
| Maximum RCF | 21,948 × g |
| Maximum Capacity | 4 × 400 mL |
| Dimensions (W×D×H) | 490 × 600 × 400 mm |
| Noise Level | <60 dB(A) |
| Power Supply | 220–230 V / 50–60 Hz or 110–120 V / 50–60 Hz |
| Power Consumption | 620 W |
| Rotor Recognition | Automatic |
| Safety Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | N 30/45H |
| Instrument Type | Box-Type Muffle Furnace |
| Max. Operating Temperature | 450 °C |
| Temperature Uniformity | ±3 K (within working chamber, per DIN 17052-1) |
| Control Accuracy | ±1 °C |
| Max. Power Consumption | 9 kW |
| Heating Rate to Max. Temp. | ≤30 min |
| Heating Element | Resistance Wire (NiCr Alloy) |
| Internal Chamber Volume Options | 5–500 L |
| Construction | Stainless Steel Inner Chamber (AISI 304), Reinforced Insulation, Horizontal Air Circulation System |
| Compliance | DIN 17052-1, EN 61000-6-3, EN 61000-6-4 |
| Brand | Leman Instruments |
|---|---|
| Origin | France |
| Model | LISAS N2 |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) |
| Output Flow | 250 mL/min or 500 mL/min (NTP) |
| Output Pressure | 0.5–5 bar (adjustable) |
| Nitrogen Purity | ≥99.999% |
| Dew Point | −40 °C |
| Filtration | 0.1 µm final particulate filter |
| Power Supply | 90–260 V AC, 47–63 Hz |
| Max. Power Consumption | 300 W |
| Dimensions (W×H×D) | 210 × 160 × 430 mm |
| Weight | 15 kg |
| Noise Level | <50 dB(A) at 1 m |
| Certifications | CE |
| Connectivity | Ethernet 10/100 & Wi-Fi |
| Display | 4.3″ TFT-LCD touchscreen |
| Compressed Air Requirement | Oil-free, dry air per ISO 8573-1 Class 3 |
| Origin | Germany |
|---|---|
| Type | Box-type Muffle Furnace |
| Max. Temperature | 1200 °C |
| Temperature Uniformity | ±1 °C |
| Heating Method | Embedded Resistance Wire in Ceramic Heating Panels |
| Internal Volume | 1–40 L |
| Power Rating | 1.2–6 kW |
| Ramp Time to Max Temp | ≤30 min |
| Construction | Double-walled Stainless Steel (V2A) Housing with Vacuum-Insulated Fiber Modules |
| Door Options | Flip-up or Lift-up Configuration |
| Safety Compliance | EN 60519-2, Thermal Protection Class 2 |
| Software Control | Compatible with Controltherm MV Process Management Suite |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Instrument Type | Benchtop Centrifuge |
| Cooling Function | Refrigerated (4 °C operation) |
| Rotor Configuration | Fixed-angle and swing-out options |
| Maximum Capacity | 4 × 100 mL |
| Maximum Speed | 16,500 rpm |
| Maximum RCF | 26,480 × g |
| Dimensions (W×D×H) | 590 × 620 × 320 mm |
| Noise Level | <60 dB(A) |
| Power Supply | 220–230 V / 50 Hz (700 W) or 110–120 V / 60 Hz (800 W) |
| Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Safety Features | Automatic lid locking, imbalance detection, overspeed protection, stainless steel chamber, autoclavable rotors & adapters |
| Brand | Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HCV400 |
| Instrument Category | Other Vacuum Pumps |
| Product Type | Oil-Free Diaphragm Vacuum Pump |
| Pumping Speed | 20 L/min |
| Ultimate Vacuum Pressure | ≤ 200 mbar (≤ −0.08 MPa gauge) |
| External Dimensions | 215 × 120 × 235 mm |
| Weight | 7.5 kg |
| Motor Power | 160 W |
| Inlet/Outlet Port Diameter | Ø6 mm |
| Operating Ambient Temperature | 7–40 °C |
| Pump Body Operating Temperature | < 55 °C |
| Noise Level | < 50 dB(A) |
| Brand | Analysis |
|---|---|
| Origin | Spain |
| Manufacturer | Ortoalresa S.L. |
| Model | BIOCEN 22R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 200–18,100 rpm |
| Max RCF | 31,865 × g |
| Max Capacity | 8 × 15 mL |
| Temperature Range | –20 °C to +40 °C (1 °C increments) |
| Refrigerant | R-449A (HFO-based, non-CFC) |
| Dimensions (W×D×H) | 276 × 640 × 272 mm |
| Noise Level | <65 dB(A) |
| Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Safety Certifications | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR), (EC) No 1005/2009, (EU) No 517/2014 |
| Brand | Leman Instruments |
|---|---|
| Origin | France |
| Model | AEROSTATION 50LC or RC |
| Hydrocarbon Removal Principle | High-Temperature Catalytic Cracking |
| Output Flow Rate | 1.5 L/min or 3 L/min |
| Maximum Output Pressure | 5 bar |
| Total Hydrocarbon (THC) Content | < 0.05 ppm (v/v) |
| Dew Point | −60 °C (DP) |
| Display & Interface | Full-color touchscreen, USB, RS485, Ethernet |
| Maintenance | Maintenance-free operation |
| Compliance | Designed for GC-FID, calibration gas standards, and permeation tube systems |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Instrument Type | Benchtop Centrifuge |
| Maximum Speed | 2500 rpm |
| Maximum RCF | 866 × g |
| Maximum Capacity | 12 × 6 mL |
| Rotor Configuration | Horizontal Swing-Out Rotor |
| Separation Target | Large Organelles / Viruses |
| Dimensions (W × D × H) | 410 mm × 530 mm × 320 mm |
| Noise Level | < 60 dB(A) |
| Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6, Directive 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU |
| Origin | Germany |
|---|---|
| Type | Box-Type Muffle Furnace |
| Max. Temperature | 1100 °C or 1200 °C |
| Temperature Accuracy | ±1 °C |
| Max. Power | 6 kW |
| Heating Rate to Max. Temperature | ≤40 min |
| Heating Method | Dual-Side Ceramic Heating Plates (Triple-Side for L24/11–LT40/12 models) |
| Internal Volume | 1–40 L |
| Compliance | EN 60519-2, IEC 61000-6-3, CE Marked |
| Brand | Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HDJS20 |
| Instrument Type | Peristaltic Pump |
| Flow Rate Range | 0.006–1340 mL/min |
| Flow Accuracy | <0.5% |
| Speed Range | 0.1–350 rpm |
| Speed Resolution | 0.1 rpm |
| Power Supply | AC 220V±10%, 50/60 Hz (standard) |
| Power Consumption | <40 W |
| External Control Interfaces | TTL-level input (5 V / 12 V standard, 24 V optional), Analog input (0–5 V standard |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <80% RH |
| Enclosure Rating | IP31 |
| Dimensions (L×W×H) | 255 × 181 × 198 mm |
| Weight | 4.7 kg |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Instrument Type | Benchtop Centrifuge |
| Cooling Function | Refrigerated (−20 °C to 40 °C) |
| Maximum Capacity | 4 × 400 mL |
| Maximum Speed | 14,300 rpm |
| Maximum RCF | 21,948 × g |
| Dimensions (W × D × H) | 670 × 770 × 390 mm |
| Noise Level | <60 dB(A) |
| Rotor Type | Swinging-bucket (standard), with optional angle and microplate rotors |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Refrigerant | R-449A (HFO-based, zero ODP, low GWP) |
| Programmable Protocols | 40 user-defined methods with password protection |
| Control Interface | TFT color touchscreen (visible from ≥3 m) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Centrifuge Type | Benchtop |
| Maximum Capacity | 4 × 400 mL |
| Maximum Speed | 14,300 rpm |
| Maximum RCF | 21,948 × g |
| Dimensions (W × D × H) | 490 × 620 × 390 mm |
| Display | TFT Color Touchscreen |
| Acceleration/Deceleration Control | Progressive (PCBS), up to 175 selectable ramps |
| Unbalance Detection System (ULS) | Real-time bucket position identification |
| Programmable Protocols | 40 user-defined methods with password protection |
| Noise Level | <60 dB(A) |
| Motor | Brushless induction motor |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Conformance | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR) |