- All
- Favorite
- Popular
- Most rated
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Manufacturer | Analysis GmbH |
| Origin Category | Imported |
| Model | UX50 |
| Pricing | Upon Request |
| Detector Type | Flat-Panel Detector (FPD) |
| Scanning Mode | Translation-Rotation (TR) |
| Accuracy | Micron-Level |
| Maximum Sample Weight | 100 kg |
| Dimensions (L×W×H) | 2250 × 1770 × 2350 mm |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Model | FF35 |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Translation-Rotation (TR) |
| X-ray Energy | 225 kV (microfocus) / 190 kV (nanofocus) |
| Maximum Penetration | 350 mm steel-equivalent |
| Spatial Resolution | up to 2.5 lp/mm |
| Density Resolution | up to 2.5 lp/mm |
| Measurement Accuracy (Metrology Version) | MPESD = 5.9 µm + L/75 [L in mm] |
| Sample Weight Capacity | up to 50 kg |
| Compliant Standards | SEMI® S2-0818, SEMI® S8-0218, VDI/VDE 2630 |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Y.MU2000-D |
| Detector Type | Flat-Panel Detector |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | Up to 2.5 lp/mm |
| Density Resolution | 0.2–0.5% |
| X-ray Energy | 225 kV |
| Maximum Penetration | 350 mm (steel equivalent) |
| Inspection Envelope | 800 mm × 1100 mm (diameter × height) |
| Dimensional Measurement Accuracy | ±0.011 mm |
| Density Measurement Accuracy | ±0.2% |
| Maximum Sample Weight | 100 kg |
| System Dimensions | 3700 mm × 2300 mm × 2800 mm (L × W × H) |
| Brand | Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model Variants | UPK-T24, UPK-T36, UPK-T48, UPK-T60, UPK-T72 |
| Water Tank Dimensions (L×W×H) | 600×450×300 mm (UPK-T24) to 4000×4000×900 mm (Custom Large-Format Systems) |
| Motion Axes | 4–8 axes with encoder feedback |
| Positioning Accuracy | ≤ 0.05 mm |
| Maximum Scan Speed | 500 mm/s |
| Ultrasonic Data Acquisition | PCIe-based integrated excitation & 14-bit ADC card |
| Bandwidth | Up to 32 MHz |
| Sampling Rate | 250 MS/s |
| Software Platform | UTwin — Multi-window, multi-modal (A/B/C/3D/CT) scanning and analysis suite |
| Brand | YXLON |
|---|---|
| Origin | Germany |
| Model | FF65 CL |
| Detector Type | Image Intensifier-Based Laminography Detector |
| Sample Diameter | 795 mm |
| Sample Height | 20 mm |
| Max Sample Weight | 2 kg |
| System Dimensions | 1760 × 2000 × 2000 mm |
| CT Mode | Super-High-Resolution Computed Laminography (CL) |
| Manipulation | Super-Precise Manipulator with Active Anti-Vibration System |
| Vacuum Sample Hold Mechanism | Integrated |
| Effective Detection Area | 510 × 610 mm |
| X-ray Source | Next-Generation Nanofocus Tube (≤ 300 nm focal spot) |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Price | Upon Request |
| Operating Temperature Range | -200 °C to +350 °C |
| Battery Life | 3–4 years (typical continuous operation) |
| Communication Protocols | WirelessHART (IEC 62591), Zigbee |
| Channels | 4 independent ultrasonic measurement channels |
| Environmental Rating | IP67-rated enclosure |
| Dual-Sensor Capability | Simultaneous thickness + ambient temperature measurement |
| Probe Compatibility | Single-crystal and dual-crystal ultrasonic transducers |
| Data Transmission | Secure, encrypted wireless transmission to local SCADA or cloud-based asset integrity platforms |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | V-400E |
| Detection Method | Pulse-Echo Mode |
| Waveform Type | Pulsed Ultrasound |
| Maximum Scan Speed | 2000 mm/s |
| Minimum Scan Area | 200 µm × 200 µm |
| RF Bandwidth | 500 MHz |
| Probe Configuration | Single Transducer (Standard) |
| Frequency Range (Optional Probes) | 100–2000 MHz |
| Axial Resolution (Typical) | <100 nm (with Nano-series transducers) |
| Integrated Optical Microscopy | Yes (Inverted & Epi-Illumination Configurable) |
| Compliance | ASTM E1783, ISO 16932, IPC-J-STD-035, JEDEC JESD22-A108 |
| Brand | PAC (Physical Acoustics Corporation) |
|---|---|
| Origin | USA |
| Manufacturer | PAC |
| Model | Tablet-UT |
| Operating System | Windows 7 Embedded (Chinese Localized) |
| Display | 10.4" XGA Touchscreen (1024×768) |
| CPU | Dual-Core x86 Processor |
| Storage | 120 GB SSD |
| Battery Life | >4 hours (Hot-Swappable Li-ion) |
| Channels | 2 independent UT channels |
| Pulse Types | Square, Spike, Tuned Burst |
| Pulse Voltage | 50–400 V |
| Input Impedance | >10 kΩ, 1.00 Ω, 100 Ω |
| Sampling Rate | >5,000 samples/sec |
| Preamp Gain | 12 dB low-noise |
| Bandwidth | 500 kHz – 20 MHz |
| Total Gain Range | 0–82 dB |
| DAC/TCG Range | 0–60 dB |
| Dynamic Range | >70 dB |
| A/D Resolution | 14-bit |
| Motor Axes | 3 |
| Encoder Outputs | 3 quadrature channels |
| Compliance | ASTM E114, E317, E1316 |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Model | UPK-T156 |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasonic |
| Scan Envelope | 4000 × 1500 × 900 mm |
| Gain Range | 0–110 dB |
| Vertical Linearity | ≤2% |
| Horizontal Linearity | ≤2% |
| Dynamic Range | ≥95 dB |
| Transducer Configuration | Single-Crystal or Through-Transmission |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Model | FF85 CT |
| Detector Type | Flat-Panel Detector (FPD) & Linear Detector Array (LDA) |
| Scan Mode | Translation-Rotation (TR) |
| Spatial Resolution | Up to 2.5 lp/mm |
| Density Resolution | 0.2–0.5% |
| X-ray Energy | 450 kV (dual-source: up to 600 kV microfocus + 300 kV minifocus) |
| Penetration Capability | 60 mm steel equivalent |
| Measurement Accuracy (Dimensional) | 0.001 mm |
| Density Measurement Accuracy | Up to 0.2% |
| Sample Weight Capacity | 100 kg |
| Max Sample Dimensions | Ø800 mm × H1100 mm |
| System Dimensions | 3700 mm × 2300 mm × 2800 mm (L×W×H) |
| Base Material | Precision Granite |
| Motion Axes | 7-axis motorized manipulator |
| Software Platform | Gemini CTScan Suite (including CTScan 3 LDA support, HeliExtend, ScatterFix 2.0, BHC, MAR) |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Model | Cheetah EVO |
| Detector Type | Flat-panel Detector |
| Scan Mode | Translation-Rotation (TR) |
| Spatial Resolution | Up to 2.5 lp/mm |
| X-ray Energy | 160 kV |
| Penetration Capability | Up to 350 mm steel-equivalent thickness |
| Precision | Nanoscale |
| Optional Features | Water-cooled X-ray tube (FXT 160.51), High-load capacity (< 20 kg), Low-dose imaging mode, Dose-reduction kit for sensitive components |
| Brand | Analysis |
|---|---|
| Model | PM1121 |
| Detection Principle | Geiger-Müller (GM) Tube-Based Ionizing Radiation Monitoring |
| Measurement Range | 0.01–10,000 µSv/h (Dose Rate), 0.01 µSv–9999 mSv (Cumulative Dose) |
| Energy Response | 40 keV–3 MeV |
| Sensitivity | >6000 CPM per µSv/h (relative to ¹³⁷Cs) |
| Alarm Response Time | ≤5 s |
| Operating Temperature | −15°C to +50°C |
| Power Supply | 2×AA batteries (alkaline or rechargeable) |
| Weight | 0.3 kg |
| Dimensions | 135 × 70 × 25 mm |
| Compliance | Designed for IEC 60846-1:2014 (Radiation Protection Instruments – Dose Rate and Dose Meters for Photon Radiation) and compatible with GLP/GMP field-use requirements |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Manufacturer | Analysis GmbH |
| Origin Category | Imported |
| Model | UX20 |
| Price | Upon Request |
| Detector Type | Flat-Panel Detector |
| Scanning Mode | Translation-Rotation (TR) |
| Accuracy | Micron-Level |
| Sample Load Capacity | 100 kg |
| Dimensions (W×D×H) | 2240 × 1770 × 2350 mm |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer | Analysis Instruments, Inc. |
| Type | Imported |
| Model | GN1500HS |
| Pricing | Available upon Request |
| Brand | Analysis |
|---|---|
| Country of Origin | Germany |
| Model | KSI V-700E |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform | Pulsed Ultrasound |
| Maximum Scan Area | 700 mm × 1000 mm |
| Gain Range | 0–120 dB |
| Dynamic Range | ≥40 dB |
| Resolution | ≥32 dB |
| Transducer Configuration | Single-Crystal |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Sensor Highway II / III |
| Instrument Category | Acoustic Emission (AE) & Multi-Parameter Structural Health Monitoring System |
| Operating Temperature Range | -35°C to +70°C |
| Power Supply | 10–28 VDC or 95–250 VAC |
| Power Consumption | 15 W (typical) |
| Dimensions | 40 cm × 50 cm × 20 cm |
| AE Channels | Up to 16 (expandable via four 4-channel micro-AE cards) |
| AE Frequency Bandwidth | 1 kHz – 1 MHz |
| Vibration Bandwidth | 1 Hz – 20 kHz |
| A/D Resolution | 18-bit |
| Sampling Rate | 20 MS/s (AE), 10 kS/s (16 low-speed external parameter channels) |
| IP Rating | IP67-rated enclosure (for outdoor deployment) |
| Communication Interfaces | Gigabit Ethernet, RS-232, RS-422, USB, CompactFlash |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Model | ARB-IPR-1210 (PCI-E) |
| Bus Interface | PCI Express |
| ADC Resolution | 12-bit |
| Sampling Rate | 100 MSPS (selectable: 100/50/25/10/5 MSPS) |
| Input Bandwidth | 0.5–30 MHz (+3 dB) |
| Gain Range | –20 to +80 dB (0.1 dB step) |
| Pulse Generator | Up to 400 V peak (<5 ns rise time), programmable pulse width & damping |
| DAC Memory | 128 KB RAM (64K points) |
| Trigger Modes | Software, external TTL, signal threshold |
| Gate Count | 4 independent gates |
| Time-of-Flight Resolution | 16-bit (10 ns) |
| Amplitude Resolution | 12-bit (488 µV) |
| Operating Temperature | 5–40 °C |
| Form Factor | Full-length PCI-E card |
| Compliance | RoHS, CE, FCC Class A |
| Software Support | LabVIEW and C++ drivers included |
| Standards Compatibility | Designed for ASTM E1158, ISO 12718, and EN 12668-1 compliant ultrasonic testing workflows |
| Brand | Ansys |
|---|---|
| Origin | USA |
| Manufacturer | Ansys, Inc. |
| Product Type | Imported |
| Model | Custom |
| Instrument Type | Digital Ultrasonic Flaw Detector |
| Inspection Method | Pulse-Echo & Through-Transmission |
| Waveform Type | Pulsed Ultrasonic |
| Scan Envelope | 1800 mm × 1800 mm × 1200 mm |
| Transducer Configuration | Single-Crystal Probes (Pulse-Echo and Through-Transmission Modes) |
| Compliance | GE Aviation Approved Design |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Model | Y.cougar |
| Detector Type | Flat-panel Detector |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | Up to 2.5 lp/mm |
| Density Resolution | 0.2–0.5% |
| X-ray Energy | 160 kV |
| Penetration Capability | Up to 350 mm steel-equivalent thickness |
| Accuracy | Nanoscale |
| Application Modes | 2D Radiography, 3D Computed Tomography (CT), Hybrid 2D/3D |
| Brand | Analysis |
|---|---|
| Model | PM1121 |
| Detector Type | Compensated Geiger-Müller (GM) Tube |
| Measurement Range | 0.01–10,000 µSv/h (dose rate), 0.01 µSv–9999 mSv (cumulative dose) |
| Energy Response | 40 keV–3 MeV |
| Sensitivity | >6000 cps per µSv/h (relative to ¹³⁷Cs) |
| Alarm Response Time | ≤5 s |
| Operating Temperature | −15°C to +50°C |
| Dimensions | 135 × 70 × 25 mm |
| Weight | 0.3 kg |
| Power Supply | Two AA batteries (alkaline or rechargeable) |
| Typical Current Draw | ≤4 mA |
| Display | Dot-matrix LCD with backlight |
| Language Options | English, Chinese, Japanese |
| Compliance | Designed for IEC 61526:2010 (Radiation protection instrumentation — Measurement of personal dose equivalents Hp(10) and Hp(0.07)) and compatible with national occupational radiation safety standards |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer | Analysis, Inc. |
| Product Type | Imported |
| Model | TCP Ultrasonic C-Scan System |
| Pricing | Available Upon Request |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Model | UPK-T24 |
| Scanning Range | 600 × 450 × 300 mm |
| Gain Range | 0–110 dB |
| Vertical Linearity | ≤2% |
| Horizontal Linearity | ≤2% |
| Dynamic Range | ≥95 dB |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasonic |
| Transducer Configuration | Single-Crystal or Through-Transmission |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | U-AT |
| Instrument Type | Digital |
| Flaw Detection Method | Pulse-Echo |
| Waveform | Pulsed Ultrasonic |
| Brand | Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | UPK-T48 |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasonic |
| Scan Envelope | 1200 × 900 × 600 mm |
| Gain Range | 0–110 dB |
| Vertical Linearity | ≤2% |
| Horizontal Linearity | ≤2% |
| Dynamic Range | ≥95 dB |
| Transducer Configuration | Single-Crystal or Through-Transmission |
Show next