Atomic Absorption Spectrometer
Filter
Showing 91–112 of 112 results
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame and Graphite Furnace AAS |
| Wavelength Range | 185–900 nm |
| Monochromator | Czerny-Turner with 1800 grooves/mm grating |
| Spectral Bandwidth | 0.2, 0.7, 1.3, 2.0 nm (4-step automatic switching) |
| Optical System | Dual-beam for flame mode |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | Simultaneous deuterium lamp (BGC-D₂, 185–430 nm) and fast self-reversal (BGC-SR, 185–900 nm) |
| Lamp Holder | 6-position, dual-lamp operation (1 pre-heating) |
| Dimensions (AA-7000F) | 700 × 588 × 714 mm, 72 kg |
| Dimensions (AA-7000G) | 700 × 580 × 538 mm, 65 kg |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Operating Environment | 10–35 °C, 20–80% RH (≤70% above 30 °C) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Automatic D₂/Zeeman |
| Resolution | 0.3 nm |
| Sensitivity | ≥ 0.3 A for 5 ppm Cu solution |
| Repeatability (RSD) | < 0.3% |
| Detection Limit (Cu) | ≤ 0.006 mg/L |
| Condition | Factory-Refurbished & Performance-Verified |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | AA-7800 |
| Price Range | USD 42,000 – 85,000 (FOB China) |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Spectral Resolution | 0.1 nm |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AAS6000 |
| Instrument Type | Flame Atomic Absorption Spectrometer |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 / 0.2 / 0.4 / 0.7 / 1.4 nm (auto-switching) |
| Grating | 1800 lines/mm, blaze wavelength 230 nm |
| Wavelength Accuracy | ±0.25 nm |
| Wavelength Repeatability | < 0.10 nm |
| Resolution | < 0.3 nm |
| Characteristic Concentration (Cu) | < 0.025 µg/mL per 1% absorption |
| Detection Limit (Cu) | < 0.006 µg/mL |
| Precision (Cu) | < 0.8% RSD |
| Baseline Stability | 0.003 Abs (static), 0.004 Abs (dynamic) |
| Background Correction | D₂ lamp + Self-absorption (up to 1 A) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AAS9000 |
| Instrument Type | Integrated Flame/GF AAS |
| Monochromator | Czerny-Turner with 1800 lines/mm grating, 230 nm blaze |
| Optical System | Double-beam |
| Detector | Solid-state CCD array |
| Background Correction | D₂ lamp + Self-absorption (AAS) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.25 nm |
| Wavelength Repeatability | < 0.05 nm |
| Spectral Bandwidth | 0.1/0.2/0.4/0.7/1.4 nm (auto-switchable) |
| Flame Cu Detection Limit | < 0.006 µg/mL |
| GF Cd Detection Limit | ≤ 1.0 pg |
| Flame Cu Precision (RSD) | < 0.8% |
| GF Cd Precision (RSD) | ≤ 2% (auto-injection), ≤ 5% (manual) |
| Temperature Control Range (GF) | Room temp – 3000 °C |
| Max GF Ramp Rate | 3000 °C/s |
| Safety Compliance | Integrated gas leak, flame status, cooling water flow, and graphite furnace temperature monitoring per IEC 61010-1 |
| [Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-3882AAS |
| Instrument Type | Flame and Graphite Furnace Atomic Absorption Spectrometer |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp, Self-absorption, and Transverse Zeeman Effect |
| Atomizer Configuration | Integrated Flame-GF Platform (No Mechanical Switching Required) |
| Burner Head | Titanium Alloy |
| Nebulizer | High-efficiency Glass Nebulizer with Optional Ceramic Upgrade |
| Graphite Furnace | Longitudinally Heated with Transverse Magnetic Field |
| Lamp System | 8-position Automatic Lamp Carousel |
| Lamp Control | Gap-controlled Hollow Cathode Lamp Power Supply |
| Safety Features | Graphite Tube Purge Gas Flow Monitoring with Auto-alarm and Interlock] |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Flame AAS |
| Model | AA3510 |
| Wavelength Range | 190–900 nm |
| Light Source | 4/6-lamp turret |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Accuracy | ±0.2 nm across full range |
| Spectral Bandwidth Options | 0.1, 0.2, 0.4, 1.0, 1.2, 2.0 nm |
| Resolution | 0.2 nm (resolves Mn doublet at 279.5/279.8 nm, valley-to-peak energy ratio <30%) |
| Monochromator | Plane grating (1800 lines/mm) |
| Optical System | Single-beam |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | D₂ lamp + self-absorption method |
| Background Correction Capacity | ≥50× at 1 ABS background signal |
| Static Baseline Drift | ≤0.002 ABS/30 min (Cu) |
| Dynamic Baseline Drift (ignition) | ≤0.004 ABS/30 min (Cu) |
| Sensitivity | ≤0.025 µg/mL for 1% absorption |
| Detection Limit (Cu) | ≤0.006 µg/mL |
| Precision (RSD) | ≤0.5% (Cu, A > 0.8 ABS) |
| Flame Systems | Air–acetylene (100 mm burner head) |
| Safety Features | Automatic gas cutoff on low pressure, power interruption, flameout, or burner mismatch |
| Dimensions | 700 × 500 × 430 mm |
| Weight | 80 kg |
| Power Supply | 220 V AC |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Absorption Method |
| Spectral Resolution | 0.2 nm |
| Sensitivity | ≤0.025 µg/mL for 1% absorption |
| RSD (Precision) | ≤0.5% |
| Cu Detection Limit | ≤0.006 µg/mL |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.2 nm across full range |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth Options | 0.1, 0.2, 0.4, 1.0, 1.2, 2.0 nm |
| Baseline Drift (Static) | ≤0.002 ABS/30 min (Cu) |
| Baseline Drift (Dynamic, Ignition) | ≤0.004 ABS/30 min (Cu) |
| Mn Doublet Resolution | Resolves 279.5/279.8 nm with valley-to-peak energy ratio <30% at 0.2 nm SBW |
| Lamp Holder | 4-lamp turret (6-lamp optional) |
| Flame Burner Heads | 100 mm air–acetylene |
| Safety Interlocks | Automatic gas cutoff on low pressure, power failure, flameout, or burner mismatch |
| Dimensions | 700 × 500 × 430 mm |
| Weight | 80 kg |
| Grating Density | 1800 lines/mm |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame AAS |
| Model | AA6810 (Single-Flame Configuration) |
| Optical System | Single-Beam |
| Monochromator | Plane Grating |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Resolution | 0.2 nm |
| Sensitivity | Cu 5 ppm, Absorbance > 0.3 A |
| Precision (RSD) | < 0.3% |
| Detection Limit (Cu) | < 0.004 µg/mL |
| Wavelength Range | 190–900 nm |
| Slit Widths | 0.1, 0.2, 0.7, 2.0 nm (motorized selection) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Drift | ≤0.0035 A / 30 min |
| Background Correction | D₂ Lamp & Self-Reversal Methods |
| Characteristic Concentration (Cu) | ≤0.025 µg/mL / 1% |
| Precision (Cu) | ≤0.5% |
| Weight | 65 kg |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame + Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal |
| Resolution | 0.2 nm |
| Sensitivity | ≤0.5% (Cu, Absorbance >0.8 AU) |
| Repeatability (RSD) | <0.5% |
| Detection Limit (Cu) | <0.004 µg/L |
| Detection Limit (Cd) | <0.3 pg |
| Characteristic Mass (Cd) | ≤0.4×10⁻¹² g |
| Characteristic Mass (Cu) | ≤10×10⁻¹² g |
| Temperature Control Accuracy | ≤1% |
| Max Ramp Rate | ≥3000 °C/s |
| Furnace Temp Range | Room Temp to 3000 °C |
| Dimensions | 700 × 550 × 440 mm |
| Weight | 80 kg |
| Power Supply | 220 V AC |
| Peak Power | 6000 W |
| Safety Features | Overcurrent Protection, Argon Pressure Monitoring, Overtemperature Cut-off |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Graphite Furnace AAS |
| Model | AA6810 (Visual Graphite Furnace) |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Reversal Method |
| Resolution | 0.2 nm |
| Sensitivity | ≤0.5% (Cu, Absorbance >0.8 ABS) |
| Precision (RSD) | ≤0.5% |
| Detection Limit (Cd, GF-AAS) | <0.3 pg |
| Max Ramp Rate | ≥3000 °C/s |
| Temperature Range | Ambient to 3000 °C |
| Characteristic Mass (Cd) | ≤0.4×10⁻¹² g |
| (Cu) | ≤10×10⁻¹² g |
| Temperature Control Accuracy | ≤1% |
| Dimensions | 700 × 550 × 440 mm |
| Weight | 80 kg |
| Power Requirement | 6000 W (peak) |
| Safety Features | Overcurrent Protection, Argon Pressure Monitoring, Overtemperature Cut-off |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | AA6810 |
| Instrument Type | Hydride Generation Accessory for Atomic Absorption Spectrometry |
| Monochromator Element | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Resolution | 0.2 nm |
| Sensitivity | Cu 5 ppm → Absorbance > 0.3 A |
| Repeatability (RSD) | < 0.3% |
| Detection Limit (Cu) | < 0.004 µg/mL |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Resolution | 0.2 nm |
| Sensitivity (Cu) | >0.3 A at 5 ppm |
| RSD (Precision) | <0.3% |
| Detection Limit (Cu) | <0.004 µg/mL |
| Wavelength Range | 190–900 nm |
| Slit Widths | 0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm (auto-switching) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Drift | 0.002 A / 30 min |
| Background Correction | D₂ Lamp & Self-Reversal |
| Characteristic Concentration (Cu) | ≤0.025 µg/mL / 1% |
| Weight | 65 kg |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Spectral Resolution | 0.2 nm |
| Sensitivity | Cu 5 ppm → Absorbance > 0.3 A |
| Repeatability (RSD) | < 0.3% |
| Detection Limit | Cu < 0.004 µg/mL |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating (1800 lines/mm) |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Wavelength Range | 190–900 nm |
| Focal Length | 270 mm |
| Slit Widths | 0.2, 0.5, 1.0, 2.0 nm (motorized) |
| Lamp Holder | 6-position, fully automated, independent lamp power supplies |
| Burner Head | Titanium alloy, finned design, optional 50 mm or 100 mm length |
| Nebulizer Chamber | Inert PTFE-nozzle & Pt/Ir capillary |
| Gas Control | Binary-valve digital pneumatic system for air/acetylene and N₂O/acetylene |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | iCE 3400 |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Echelle Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Zeeman Electro-Magnetic Field Correction |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | iCE 3500 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Echelle Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal (Auto-Absorption) |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Dual-Beam (Optical for Flame / Electronic for GF) |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Detection Limit (Cu, Flame) | ≤0.002 μg/mL |
| Baseline Stability | Zero Drift ±0.002 Abs / 30 min |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WFX-320 |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-beam |
| Detector | Photomultiplier Tube (PMT) |
| Resolution | Resolves Mn 279.5 nm and 279.8 nm doublet with valley energy <36% |
| Sensitivity | Cu 0.04 µg/mL per 1% absorption |
| Repeatability (RSD) | ≤0.9% (flame mode) |
| Detection Limit | Cu 0.007 µg/mL (flame mode) |
| Optional Accessory | Hydride Generation System |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Single-beam Czerny-Turner monochromator with 1800 lines/mm holographic grating |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 / 0.2 / 0.4 / 1.0 / 2.0 nm (5-step auto-switching) |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Baseline Stability | ≤0.003 A/30 min (dynamic), ≤0.002 A/30 min (static) |
| Resolution | <0.1 nm |
| Flame Cu Detection Limit | ≤0.003 µg/mL |
| Flame Cu Characteristic Concentration | ≤0.02 µg/mL/1% |
| Graphite Furnace Cd Characteristic Mass | 0.3×10⁻¹² g |
| Graphite Furnace Detection Limit | 0.2×10⁻¹² g |
| Graphite Furnace Temperature Range | Room temperature to 3000 °C |
| Max. Graphite Furnace Ramp Rate | ≥3000 °C/s (optical control), ≥2000 °C/s (power control) |
| Background Correction | D₂-lamp and self-absorption (AAS) modes, correction capacity >60× at 1.0 A background absorbance |
| Sample Introduction | Manual or automated (flame/graphite furnace/hydride generation) |
| Dimensions (W×D×H) | 880 × 540 × 450 mm |
| Weight | 125 kg |
| Power Supply | AC 220 V, 50 Hz |
| Main unit | 500 W |
| Graphite furnace module | 5 kW |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Czerny-Turner grating monochromator with 1800 lines/mm grating |
| Optical System | Single-beam |
| Background Correction | Deuterium lamp + Self-reversal (Self-absorption) background correction |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1/0.2/0.4/1.0/2.0 nm (5-step automatic switching) |
| Cu Detection Limit (Flame) | ≤0.003 µg/mL |
| Cd Characteristic Mass (GFAAS) | 0.3×10⁻¹² g |
| Cd Detection Limit (GFAAS) | 0.2×10⁻¹² g |
| Graphite Furnace Temp. Range | Room temperature to 3000 °C |
| Max. Sample Volume (GFAAS) | 70 µL |
| Background Correction Capacity | >60× at up to 1.0 A absorbance |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame-Graphite Furnace Hybrid AAS |
| Background Correction | Dual-mode Deuterium Lamp + Longitudinal AC Zeeman |
| Optical Grating | 1800 lines/mm |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1/0.2/0.4/1.0/2.0 nm (auto-switchable) |
| Flame Cu Detection Limit | ≤0.003 µg/mL |
| Graphite Furnace Cd Characteristic Mass | 0.5×10⁻¹² g |
| Graphite Furnace Detection Limit | 10×10⁻¹² g |
| Max Graphite Furnace Temp | 2700 °C |
| Heating Rate | ≥2500 °C/s |
| Background Correction Capacity | >60× (flame, D₂), >100× (GF, Zeeman at ~2.0 Abs) |
| Auto-sampler Compatibility | AS-600 Integrated Flame/GF Autosampler |
| Software Compliance | Audit Trail, Electronic Signature, Role-Based Access Control, 21 CFR Part 11 Readiness |