BrandBeifen Sanpu
OriginHebei, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSecondary Thermal Desorber
Automation LevelFully Automated
Desorption Zone Temperature Range150–380 °C
Valve Oven Temperature RangeAmbient to 260 °C (1 °C increments)
Transfer Line Temperature RangeAmbient to 260 °C (1 °C increments
Cold Trap Temperature Range–35 °C to ambient (1 °C increments
Temperature Control Accuracy< ±0.5 °C
Sample CapacityDual 12-, 20-, or 24-position trays
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelAT1DS-20B
Instrument TypeSecondary Thermal Desorber
Desorption Temperature RangeAmbient to 450 °C
Cold Trap Temperature Range−35 °C to Ambient
Desorption Recovery Rate>90%
Sample Capacity40 positions (dual 20-position carousel)
Temperature Control Accuracy< ±0.5 °C
RSD≤2.5% (for 0.05 μg benzene in methanol)
Cold Trap Cooling MethodSemiconductor-based electronic cooling
Sample Tube Format1/4″ OD × 3.5″ (ASTM D6196-compliant)
Valve ActuationMotor-driven 6-port switching valve
Dimensions (L×W×H)350 mm × 450 mm × 550 mm
Weight~40 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic Laboratory GC
ModelGC-2010F
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose / Forensic Toxicology
Oven Temperature Range420 °C
Maximum Ramp Rate40 °C/min
Cool-down Time~8 min (from 420 °C to 50 °C)
Carrier Gas Flow Range & Control0–800 mL/min
Carrier Gas Pressure Range & Control0–600 kPa
Injector Maximum Operating Temperature420 °C
Injector Pressure Setting Range0–600 kPa
Injector Total Flow Setting Range0–800 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelLH-24B
Temperature Control RangeAmbient to 400 °C
Gas Flow Rate0–1000 mL/min
Tube Capacity24 tubes
Power Supply220 VAC, 50 Hz
Power Consumption<200 VA
Temperature Accuracy±1 °C
Maximum Aging Duration>999 h
Simulated Sampling Time0–99 min
Tube Dimensions (Standard)Ø6 mm × ≥110 mm or 1/4″ OD × ≥3.5″
Dimensions (H×W×D)350 × 230 × 330 mm
Net Weight~12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
ManufacturerBeifen Sanpu Instrument Co., Ltd.
ModelPT-80A
Sample Capacity80 positions (40 mL VOA vials)
Injection PrecisionRSD ≤ 3%
Trap Temperature RangeAmbient to 380 °C
Cooling250 °C → 35 °C in ≤ 90 s
Purge Tube TemperatureAmbient to 95 °C
Sample ChillingAmbient only
Cold Trap Temperature−40 °C to ambient (Peltier + air cooling)
Desorption Flow Path HeatingAmbient to 220 °C
Water Removal TrapAmbient to 400 °C
Purge Flow Rate0–150 mL/min
Timing Resolution0.1 s
Max Duration100 min
Timing Accuracy< 0.1 s
System Pressure Rating≤ 0.6 MPa
Power SupplyAC 220 V, 50 Hz
Power Consumption800 W
Dimensions750 × 500 × 550 mm
Weight~50 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSanpu
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automated
Sample Vial Capacity20 positions
Vial Size Compatibility10 mL or 20 mL
Vial Heating RangeAmbient to 200 °C (1 °C increment)
Valve & Transfer Line Temperature Range40–220 °C
Temperature Control Accuracy±1 °C
Quantitative Loop Volume1 mL
Pressure Control Range0–0.25 MPa (continuously adjustable)
Sampling Time0–30 min
Pressurization Time0–999 s
Injection Time0–999 s
Bake-out Time0–30 min
RSD<1.0% (for 100 ppm ethanol in water)