| Brand | Beifen Sanpu |
|---|---|
| Model | GC-9860 with FID Detector + AHS-610 Headspace Sampler |
| Origin | Beijing, China |
| Manufacturer | Beifen Sanpu Instrument Co., Ltd. |
| Temperature Control Range | 450 °C |
| Oven Ramp Rate | 39 °C/min |
| Oven Cool-down Rate | 35 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–450 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–450 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Safety Testing |
| Oven Temperature Range | 100–350 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Time (350→100 °C) | ~6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Gas Chromatograph |
| Model | GC-3420A |
| Price Range | USD 4,200 – 7,000 |
| Application Field | General-purpose Environmental Air Monitoring |
| Temperature Control Range | Ambient to 400 °C |
| Ramp Rate | Up to 40 °C/min |
| Cooling Rate | Forced air cooling, <5 min from 300 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–100 mL/min (N₂, H₂, He), electronic pressure/flow control (EPC) |
| Inlet Pressure Range | 0–100 psi |
| Maximum Inlet Temperature | 450 °C |
| Brand | Beifen Sanpu |
|---|---|
| Model | GC-9860-FID |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Alcoholic Beverage Chromatography |
| Oven Temperature Range | 450 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cool-down Time | ~8 min |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–1000 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–1000 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Gas Chromatograph |
| Model | GC9860-IV |
| Temperature Control Range | 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–39 °C/min |
| Cooling Rate | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Accuracy | ±0.05 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | ±0.05 kPa |
| Total Injector Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 6 independent zones |
| Temperature Increment | 1 °C |
| Temperature Stability | ±0.1 °C |
| Programmed Temperature Steps | 16 |
| External Events | 8 channels |
| Auxiliary Outputs | 4 channels |
| Supported Inlet Types | Packed column, capillary column, 6-port gas valve, headspace auto-sampler |
| Detector Capacity | Up to 3 simultaneous detectors |
| Compatible Detectors | FID, TCD, ECD, FPD, NPD |
| Gas Control Mode | Full Electronic Pressure Control (EPC) |
| EPC Operating Modes | Constant Flow, Constant Pressure |
| Supported Carrier Gases | N₂, H₂, Air, He, Ar |
| Key | Brand: Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical & Cosmetic Quality Control |
| Max Oven Temperature | 450 °C |
| Heating Rate | 0.1–80 °C/min |
| Cooling Rate | 40 °C/min |
| Carrier Gas Flow Range | 0–1200 sccm |
| Carrier Gas Pressure Range | 0–0.4 MPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Set Range | 0–0.4 MPa |
| Injector Total Flow Set Range | 0–1200 sccm |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Detection Method | Flame Ionization Detection (FID) |
| Column Configuration | Capillary Column (30 m × 0.25 mm × 0.25 µm) |
| Headspace Autosampler | AHS-20A (20-position) |
| Application Field | Food Industry–Specific Solvent Residue Testing |
| Compliance Standard | GB/T 5009.262–2016 |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Gas Chromatograph |
| Model | GC9860-5U |
| Price Range | USD 4,200 – 7,000 (FOB Beijing) |
| Temperature Control Range | 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–39 °C/min |
| Cool-down Time | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 6 independently controlled |
| Programmed Temperature Ramping | Up to 16 steps |
| EPC/EFC Capabilities | Dual-mode (constant pressure / constant flow), supports N₂, H₂, Air, He, Ar |
| Pressure Accuracy | ±0.01 kPa |
| Flow Accuracy | ±0.01 sccm |
| Detector Options | FID, TCD, ECD, NPD (up to 3 simultaneously) |
| Data Interface | Ethernet (IEEE 802.3) |
| Display | 192×64 dot-matrix LCD or optional 7-inch industrial tablet |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | ATDS-3420HP |
| Temperature Control Range | 100–450 °C |
| Oven Ramp Rate | 0.1–80 °C/min |
| Oven Cool-down Time | ~7 min (from 450 °C to 100 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–400 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–400 kPa |
| Injector Total Flow Setting Range | 0–100 mL/min] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9860-VI |
| Temperature Control Range | Ambient to 450 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Cool-down Time | ~8 min (from 450 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detection Method | Flame Ionization Detection (FID) |
| Sample Introduction | Automated Headspace Sampling (AHS-20A Plus) |
| Compliant Standard | GA/T 842–2019 (China Public Security Industry Standard for Blood Alcohol Testing) |
| Brand | BFSANPU |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical Analysis |
| Oven Temperature Range | Ambient +5°C to 400°C |
| Temperature Control Accuracy | ±0.1°C |
| Programmable Ramp Rate | 0.1–50°C/min |
| Maximum Programmed Steps | 8 |
| Injector Temperature Range | 100–350°C |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Detector Configurations | Up to 4 simultaneous detectors (dual FID, dual TCD, dual ECD, or mixed combinations) |
| Dimensions (L×H×W) | 520×480×500 mm |
| Weight | 50 kg |
| Power Requirement | 220 V ±10%, 2500 W |
| Brand | Beifen Sanpu |
|---|---|
| Model | GC-9860 |
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Focus | Environmental Analysis |
| Temperature Control Range | Ambient ±8 °C to 450 °C (1 °C increment) |
| Ramp Rate | 0.1–40 °C/min (0.1 °C increment) |
| Oven Cooling | Motor-driven rear door with intelligent stepper control |
| Detector Compatibility | FID, TCD, ECD, FPD, Ni-converter furnace |
| Inlet Configurations | Two independent inlets + one valve inlet |
| Autosampler Ready | Compatible with multi-position liquid autosamplers, headspace samplers, and thermal desorbers |
| Data System | Embedded bidirectional control software with valve timing control (e.g., 6-port, 10-port) |
| Pressure Protection | Automatic power cutoff at carrier gas pressure <0.1 MPa |
| Power | 220 V, 50 Hz, 2000 W |
| Dimensions | 59 × 48 × 49 cm |
| Weight | 40 kg |
| Temperature Zones | 10 independently controlled zones |
| Programmed Temperature | 16-step ramping |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose VOC Analysis |
| Oven Temperature Range | 100–350 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Time (100–350 °C) | ~6 min |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Max Operating Temperature | 100–350 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1000 mL/min] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-9860-IV-1 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental & Food Safety Testing |
| Oven Temperature Range | 450 °C |
| Maximum Ramp Rate | 80 °C/min |
| Maximum Cooling Rate | 40 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0.4–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | Multi-2025 |
| Price | USD 28,000 (approx.) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Maximum Cooling Rate | 40 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | SP-3400 |
| Instrument Type | Online Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 4°C to 450°C |
| Oven Ramp Rate | 0.1–39°C/min |
| Oven Cooling Time | ~6 min (from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0.1–1200 mL/min |
| Carrier Gas Pressure Range & Control | ±0.05 kPa |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | ±0.05 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector Options | TCD, FID, ECD, FPD, TSD |
| Injector Types | Packed Column Injector, Split/Splitless Capillary Injector |
| Method Storage Capacity | 4 methods |
| Key Features | Real-time self-diagnosis, programmable detector range/attenuation, automated valve & signal switching, multi-safety interlocks (TCD flow failure, overtemperature, FPD light leakage), microprocessor-based full-keyboard interface |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | ASH-20A Plus + GC9860-5C |
| Temperature Control Range | 100–350 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Maximum Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Total Injector Flow Setting Range | 0–1000 mL/min |
| Detection Method | Headspace-GC/FID |
| Compliance Standards | GB 5749–2006, GB 3838–2002, GB 8537–2008 |
| Brand | Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Gas Chromatograph |
| Application Field | Pharmaceutical Analysis |
| Temperature Control Range | +4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down | 450 °C → 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9860HP |
| Temperature Control Range | 100–450 °C |
| Oven Ramp Rate | 0.1–80 °C/min |
| Oven Cool-down Time | ~7 min (from 450 °C to 100 °C) |
| Carrier Gas Flow Range | 0–1000 mL/min |
| Carrier Gas Pressure Range | 0–400 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–400 kPa |
| Injector Total Flow Setting Range | 0–100 mL/min |
| Detection Method | Flame Ionization Detection (FID) |
| Column Compatibility | Capillary columns (e.g., 30 m × 0.32 mm × 0.5 µm LZP-930) |
| Brand | North Branch Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | GC-8000 |
| Pricing | Available Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GC-9860 |
| Communication Interface | 10/100 Mbps Adaptive Ethernet |
| Max Concurrent Instruments | 5,000 |
| Data Import Format | AIA/CDF (ASTM E1947-compliant) |
| Analog Input Range | ±2.5 V |
| Integration Sensitivity | 0.05 µV·s |
| Minimum Resolution | 1 µV |
| Dynamic Range | 10⁷ |
| Linearity | ±0.005% |
| Repeatability | ±0.005% |
| Sampling Rate | Adjustable from 10 to 50 Hz |
| Peak Detection | Intelligent automated peak identification with baseline correction and deconvolution of co-eluting peaks |
| Quantitation Methods | Normalization, corrected normalization, single-point internal/external standard, multi-point internal/external calibration |
| Software Architecture | Multi-threaded, seat-scalable client-server system |
| Remote Data Export Protocols | HTTP/HTTPS, MODBUS TCP, CANopen, GPRS, 3G, private wireless network |
| Compliance | Designed for GLP/GMP environments |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GC-2010 |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 5 °C above ambient to 400 °C |
| Max. Oven Ramp Rate | 40 °C/min |
| Cooling Rate | 320 °C/min (with intelligent back-door system) |
| Carrier Gas Flow Range & Control | 0–856 mL/min |
| Carrier Gas Pressure Range & Control | 0–621 psi |
| Injector Max. Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–532 psi |
| Total Injector Flow Setting Range | 0–452 mL/min |
| Detection System | FID with optimized hydrocarbon response |
| Column Configuration | 50 m × 0.53 mm ID × 0.25 µm PLOT capillary column |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Detection Principle | Purge-and-Trap / Gas Chromatography–Cold Vapor Atomic Fluorescence Spectrometry (GC-CVAFS) |
| Compatible With | Commercial Purge-and-Trap Concentrators |
| GC Column | Modified OV-3 Packed Column |
| Pyrolysis Temperature | Up to 1050 °C |
| Detection Elements | As, Hg, Pb, Se, Sb, Bi, Cd (12 total) |
| Regulatory Compliance | HJ 977–2018, HJ 1269–2022, HJ 1268–2022, SNT 5517–2023 |
| Software | Graphical Interface with Real-Time Status Monitoring, Consumable Lifetime Tracking, Multi-Format Reporting (Word/Excel/PDF) |
| Application Scope | Environmental water, soil, sediment, biological tissues, cosmetics, herbal medicine, feed, and seafood matrices |