| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-2010 + AHS-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Vial Heating Temperature Range | Up to 200 °C |
| Valve & Transfer Line Temperature Control Range | Up to 200 °C |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL and 20 mL vials |
| Compliance | Designed for GB/T 5750.8–2006 and GB/T 5750.10–2006 methods |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | AHS-10A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient to 200 °C |
| Valve & Quantitation Loop Temperature Control Range | Ambient to 220 °C |
| Quantitation Loop Volume | 1 mL |
| Vial Capacity | 12 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Temperature Control Accuracy | < ±0.5 °C |
| RSD (n=6, 40 ppm ethanol in water) | ≤1.5% |
| Purge Flow Rate | 0–500 mL/min (continuously adjustable) |
| Dimensions (L×W×H) | 200 × 360 × 420 mm |
| Weight | ~18 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-3430 |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 450 °C |
| Cryo-Focusing Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Position Capacity | 1 tube |
| Dimensions | 380 × 220 × 410 mm |
| Weight | ~15 kg |
| Power Consumption | 500 W |
| Temperature Control Accuracy | < ±0.5 °C |
| RSD | ≤2.5% (for 0.05 μg benzene in methanol) |
| Second-Stage Heating Rate | >3000 °C/min |
| Peak Width | <3 s |
| Sample Tube Compatibility | OD ≤6.5 mm, L ≥150 mm |
| Brand | Sanfen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | PT-80A |
| Instrument Category | Water-and-Soil Integrated |
| Sample Tray Capacity | 80 positions |
| Injection Precision | RSD ≤ 3% |
| Trap Temperature Range | Ambient to 380 °C |
| Cooling | 250 °C → 35 °C in ≤ 90 s |
| Sample Heating (Liquid) | Ambient to 95 °C |
| Sample Chilling | Ambient only |
| Cold Trap Temperature | −40 °C to ambient (Peltier + air cooling) |
| Blowback Flow Separation | Yes |
| Foam Sensor | Integrated |
| PEEK & Silanized Stainless Steel Tubing | Yes |
| Hot Water Rinse Capability | Yes |
| GC/GC-MS Synchronization | Dual TTL outputs, 1–2 s trigger latency |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Quantitative Loop Volume | 1 mL |
| Sample Position Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL vials |
| Temperature Stability | < ±0.5 °C |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Communication Interface | USB |
| Compliance | GB/T 16886.7–2001, USP <467>, ISO 10993-7, ASTM D6866, HJ 642–2013, HJ 643–2013, HJ 714–2014, HJ 810–2016, ChP 2015 Vol. III & IV, FDA 21 CFR Part 11 (via compatible CDS) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | LH-24A |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0–500 mL/min (expandable to 0–1000 mL/min per specification) |
| Tube Capacity | 24 adsorption tubes |
| Control Accuracy | ±1 °C |
| Max Aging Duration | >999 h |
| Dimensions (H×W×D) | 350 mm × 230 mm × 330 mm |
| Net Weight | ~12 kg |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | <200 VA |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Beifen Sanpu Instruments Co., Ltd. |
| Model | A’HS-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 20-position carousel |
| Compatible Vial Sizes | 10 mL or 20 mL vials |
| Compliance Standard | HJ 1067–2019 |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | AH-S-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL vials |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Loop Volume | 1 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | AvHS-20A PLUS |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region Category | Domestic (China) |
| Model | AHS-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Primary Desorption Temp Range | Ambient to 450 °C |
| Secondary Desorption Temp Range | 100 to 450 °C |
| Cryo-Focusing Trap Temp Range | −35 to Ambient °C |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 20 positions |
| Dimensions | 350 × 450 × 510 mm |
| Weight | ~40 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | ALHS-20A PLUS |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |
| Brand | North分Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Primary Desorption Temp Range | Ambient to 400 °C |
| Secondary Desorption Temp Range | 100–400 °C |
| Cryo-Trap Temp Range | Down to −35 °C |
| Desorption Recovery Rate | >90% |
| Sample Capacity | 20 positions |
| Brand | Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL vials |
| Brand | Beifen Sanpu |
|---|---|
| Model | AHS-20B |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 20 vials |
| Simultaneous Heating Positions | 6 |
| Vial Size | 20 mL (customizable: 10 mL, 50 mL, 100 mL) |
| Oven Temperature Range | 40–220 °C (optional up to 300 °C), accuracy ±1 °C |
| Valve & Transfer Line Temperature Range | 40–220 °C (optional up to 300 °C), accuracy ±1 °C |
| Temperature Stability | <±0.5 °C |
| Temperature Accuracy | ±0.5% of setpoint |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Cleaning Time | 0–30 min |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Loop Volume | 1 mL (customizable: 0.5 mL, 2 mL, 5 mL) |
| RSD | <1.5% (100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (continuously adjustable) |
| Communication Interface | USB |
| Net Weight | 31.25 kg |
| Compliance | Designed for GLP/GMP environments |
| Brand | Beifen Sanpu |
|---|---|
| Model | ED-6 |
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multifunctional Gas/Liquid Autosampler |
| Maximum Sample Capacity | 60 vials |
| Minimum Injection Volume | 0.1 µL |
| Quantitative Loop Volume | 1000 µL |
| Positioning Accuracy | <0.3 mm |
| Motion System | XYZ Three-Axis Stepper Motor Drive |
| Needle Wash Mode | Internal & External Wall Rinse, Unlimited Cycles |
| Repeat Injection Capability | Unlimited |
| Interface | USB 2.0 |
| Optional Features | 12-inch Touchscreen Display, Full-Path Thermal Insulation (RT–200 °C, ±0.5 °C), GC Start Trigger Output |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | ATDS-3420 |
| Instrument Type | Dual-Stage Thermal Desorber |
| Primary Desorption Temperature Range | Ambient to 400 °C |
| Secondary Desorption Temperature Range | 100–400 °C |
| Cold Trap Temperature Range | Down to –35 °C |
| Desorption Recovery Rate | >90% |
| Sample Capacity | 20 adsorption tubes |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LH-10 |
| Temperature Control Range | Ambient to 450 °C |
| Gas Flow Rate | 0–200 mL/min |
| Tube Capacity | 10 tubes |
| Power Supply | 220 VAC, 50 Hz |
| Power Consumption | <200 VA |
| Temperature Accuracy | ±1 °C |
| Maximum Aging Duration | >999 h |
| Simulated Sampling Time | 0–99 min |
| Flow Adjustment Range | 0–1000 mL/min |
| Tube Dimensions (Standard) | Ø6 mm × ≥110 mm |
| Dimensions (H×W×D) | 225 × 265 × 345 mm |
| Net Weight | ~10.5 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ATDS-20A |
| Instrument Type | Dual-Stage Thermal Desorber / Thermal Desorber |
| Primary Desorption Temperature Range | Ambient to 400 °C |
| Secondary Desorption Temperature Range | 100–400 °C |
| Cold Trap Temperature Range | Down to −35 °C |
| Desorption Recovery Rate | >90% |
| Sample Capacity | 20 positions |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ATD1S-20A |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Dual-stage thermal desorber |
| Desorption Temperature Range | Ambient to 400 °C |
| Cold Trap Temperature Range | −30 °C to 400 °C |
| Desorption Recovery Rate | ≥95% (for C6–C12 VOCs per ISO 21045) |
| Sample Position Capacity | 20 tubes |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | AHS-10A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 12 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ATDS-3430 |
| Instrument Type | Dual-Stage Thermal Desorber |
| Primary Application | Compliance with GB 50325-2020 for Indoor Environmental VOC Monitoring |
| Desorption Temperature Range | Ambient to 450 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Position Capacity | 1 tube |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Category | Domestic |
| Model | PT-80A |
| Sample Tray Capacity | 80 positions (40 mL VOA vials) |
| Injection Precision | RSD ≤ 3% |
| Trap Desorption Temperature Range | Ambient to 380 °C |
| Cooling | 250 °C → 35 °C in ≤ 90 s |
| Purge Heater Temperature | Ambient to 95 °C |
| Sample Chiller Temperature | Ambient |
| Cold Trap Temperature Range | –40 °C to ambient (Peltier + air cooling) |
| Purge Flow Rate | 0–150 mL/min |
| Tube Heating Zone | Ambient to 220 °C |
| Water Removal Trap | Ambient to 400 °C |
| Rinse Water Temperature | Ambient to 90 °C |
| Solid Sample Heating | Ambient to 100 °C |
| Trap Dimensions | Quartz, Φ4 mm × 80 mm × 1 mm wall thickness |
| Timing Resolution | 0.1 s |
| Max Duration | 100 min |
| Timing Accuracy | < 0.1 s |
| Pneumatic Pressure Rating | ≤ 0.6 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 800 W |
| Dimensions (W×D×H) | 750 × 500 × 550 mm |
| Weight | ~50 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Injection Valve Temperature Control Range | Ambient to 200 °C (1 °C increments) |
| Quantitative Loop Volume | 1 mL |
| Vial Capacity | 12 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |
| Integrated GC Trigger Output | Yes |
| Method Storage | 10 user-editable methods |
| Safety Features | Overtemperature cutoff with thermal shutdown |