Empowering Scientific Discovery

Beijing Beifen-Sanpu Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelGC-2010 + AHS-20A Plus
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automated
Vial Heating Temperature RangeUp to 200 °C
Valve & Transfer Line Temperature Control RangeUp to 200 °C
Sample Loop Volume1 mL
Sample Capacity20 positions
Compatible Vial Sizes10 mL and 20 mL vials
ComplianceDesigned for GB/T 5750.8–2006 and GB/T 5750.10–2006 methods
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Regional CategoryDomestic (China)
ModelAHS-10A
Instrument TypeStatic Headspace Sampler
Automation LevelSemi-Automatic
Vial Heating RangeAmbient to 200 °C
Valve & Quantitation Loop Temperature Control RangeAmbient to 220 °C
Quantitation Loop Volume1 mL
Vial Capacity12 positions
Vial Size Compatibility10 mL or 20 mL
Temperature Control Accuracy< ±0.5 °C
RSD (n=6, 40 ppm ethanol in water)≤1.5%
Purge Flow Rate0–500 mL/min (continuously adjustable)
Dimensions (L×W×H)200 × 360 × 420 mm
Weight~18 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelATDS-3430
Instrument TypeDual-Stage Thermal Desorber
Desorption Temperature RangeAmbient to 450 °C
Cryo-Focusing Trap Temperature Range−35 °C to Ambient
Desorption Recovery Rate>99% (compound-dependent)
Sample Position Capacity1 tube
Dimensions380 × 220 × 410 mm
Weight~15 kg
Power Consumption500 W
Temperature Control Accuracy< ±0.5 °C
RSD≤2.5% (for 0.05 μg benzene in methanol)
Second-Stage Heating Rate>3000 °C/min
Peak Width<3 s
Sample Tube CompatibilityOD ≤6.5 mm, L ≥150 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSanfen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginDomestic (China)
ModelPT-80A
Instrument CategoryWater-and-Soil Integrated
Sample Tray Capacity80 positions
Injection PrecisionRSD ≤ 3%
Trap Temperature RangeAmbient to 380 °C
Cooling250 °C → 35 °C in ≤ 90 s
Sample Heating (Liquid)Ambient to 95 °C
Sample ChillingAmbient only
Cold Trap Temperature−40 °C to ambient (Peltier + air cooling)
Blowback Flow SeparationYes
Foam SensorIntegrated
PEEK & Silanized Stainless Steel TubingYes
Hot Water Rinse CapabilityYes
GC/GC-MS SynchronizationDual TTL outputs, 1–2 s trigger latency
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automated
Sample Vial Heating RangeAmbient to 200 °C (1 °C increments)
Valve & Transfer Line Temperature Control Range40–220 °C (±1 °C accuracy)
Quantitative Loop Volume1 mL
Sample Position Capacity20 positions
Compatible Vial Sizes10 mL or 20 mL vials
Temperature Stability< ±0.5 °C
RSD< 1.0% (for 100 ppm ethanol in water)
Pressure Control Range0–0.25 MPa (continuously adjustable)
Sampling Time0–30 min
Injection Time0–999 s
Purge/Flush Time0–30 min
Minimum Time Resolution1 ms
Communication InterfaceUSB
ComplianceGB/T 16886.7–2001, USP <467>, ISO 10993-7, ASTM D6866, HJ 642–2013, HJ 643–2013, HJ 714–2014, HJ 810–2016, ChP 2015 Vol. III & IV, FDA 21 CFR Part 11 (via compatible CDS)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelLH-24A
Temperature Control RangeAmbient to 400 °C
Gas Flow Rate0–500 mL/min (expandable to 0–1000 mL/min per specification)
Tube Capacity24 adsorption tubes
Control Accuracy±1 °C
Max Aging Duration>999 h
Dimensions (H×W×D)350 mm × 230 mm × 330 mm
Net Weight~12 kg
Power Supply220 VAC, 50 Hz
Power Consumption<200 VA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
ManufacturerBeifen Sanpu Instruments Co., Ltd.
ModelA’HS-20A Plus
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Vial Heating RangeAmbient to 200 °C (1 °C increments)
Valve & Transfer Line Temperature Control Range40–220 °C (±1 °C accuracy)
Sample Loop Volume1 mL
Sample Capacity20-position carousel
Compatible Vial Sizes10 mL or 20 mL vials
Compliance StandardHJ 1067–2019
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeManufacturer
Regional CategoryDomestic (China)
ModelAH-S-20A Plus
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Sample Tray Capacity20 positions
Vial Size Compatibility10 mL or 20 mL vials
Vial Heating RangeAmbient to 200 °C (1 °C increments)
Valve & Transfer Line Temperature Control Range40–220 °C
Temperature Control Accuracy±1 °C
Sample Loop Volume1 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeManufacturer
Regional CategoryDomestic (China)
ModelAvHS-20A PLUS
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Vial Heating RangeAmbient to 200 °C (1 °C increment)
Valve Temperature Control Range40–220 °C (±1 °C accuracy)
Sample Loop Volume1 mL
Vial Capacity20 positions
Compatible Vial Sizes10 mL or 20 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Region CategoryDomestic (China)
ModelAHS-20A Plus
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Vial Heating RangeAmbient to 200 °C (1 °C increments)
Valve Temperature Control Range40–220 °C (±1 °C accuracy)
Sample Loop Volume1 mL
Sample Capacity20 positions
Vial Size Compatibility10 mL or 20 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTwo-Stage Thermal Desorber
Primary Desorption Temp RangeAmbient to 450 °C
Secondary Desorption Temp Range100 to 450 °C
Cryo-Focusing Trap Temp Range−35 to Ambient °C
Desorption Recovery Rate>99% (compound-dependent)
Sample Capacity20 positions
Dimensions350 × 450 × 510 mm
Weight~40 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeManufacturer
Region of OriginDomestic (China)
ModelALHS-20A PLUS
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Vial Heating RangeAmbient to 200 °C (1 °C increment)
Valve Temperature Control Range40–220 °C (±1 °C accuracy)
Sample Loop Volume1 mL
Sample Capacity20 positions
Compatible Vial Sizes10 mL or 20 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNorth分Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTwo-Stage Thermal Desorber
Primary Desorption Temp RangeAmbient to 400 °C
Secondary Desorption Temp Range100–400 °C
Cryo-Trap Temp RangeDown to −35 °C
Desorption Recovery Rate>90%
Sample Capacity20 positions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Vial Heating RangeAmbient to 200 °C (1 °C increments)
Valve Temperature Control Range40–220 °C (±1 °C accuracy)
Sample Loop Volume1 mL
Sample Capacity20 positions
Compatible Vial Sizes10 mL or 20 mL vials
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
ModelAHS-20B
Automation LevelFully Automated
Sample Tray Capacity20 vials
Simultaneous Heating Positions6
Vial Size20 mL (customizable: 10 mL, 50 mL, 100 mL)
Oven Temperature Range40–220 °C (optional up to 300 °C), accuracy ±1 °C
Valve & Transfer Line Temperature Range40–220 °C (optional up to 300 °C), accuracy ±1 °C
Temperature Stability<±0.5 °C
Temperature Accuracy±0.5% of setpoint
Pressurization Time0–999 s
Sampling Time0–30 min
Injection Time0–999 s
Cleaning Time0–30 min
Pressurization Pressure0–0.25 MPa (continuously adjustable)
Loop Volume1 mL (customizable: 0.5 mL, 2 mL, 5 mL)
RSD<1.5% (100 ppm ethanol in water)
Purge Flow Rate0–100 mL/min (continuously adjustable)
Communication InterfaceUSB
Net Weight31.25 kg
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
ModelED-6
OriginHebei, China
Manufacturer TypeDirect Manufacturer
Instrument TypeMultifunctional Gas/Liquid Autosampler
Maximum Sample Capacity60 vials
Minimum Injection Volume0.1 µL
Quantitative Loop Volume1000 µL
Positioning Accuracy<0.3 mm
Motion SystemXYZ Three-Axis Stepper Motor Drive
Needle Wash ModeInternal & External Wall Rinse, Unlimited Cycles
Repeat Injection CapabilityUnlimited
InterfaceUSB 2.0
Optional Features12-inch Touchscreen Display, Full-Path Thermal Insulation (RT–200 °C, ±0.5 °C), GC Start Trigger Output
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginShanghai, China
Manufacturer TypeOEM Manufacturer
Product CategoryDomestic
ModelATDS-3420
Instrument TypeDual-Stage Thermal Desorber
Primary Desorption Temperature RangeAmbient to 400 °C
Secondary Desorption Temperature Range100–400 °C
Cold Trap Temperature RangeDown to –35 °C
Desorption Recovery Rate>90%
Sample Capacity20 adsorption tubes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelLH-10
Temperature Control RangeAmbient to 450 °C
Gas Flow Rate0–200 mL/min
Tube Capacity10 tubes
Power Supply220 VAC, 50 Hz
Power Consumption<200 VA
Temperature Accuracy±1 °C
Maximum Aging Duration>999 h
Simulated Sampling Time0–99 min
Flow Adjustment Range0–1000 mL/min
Tube Dimensions (Standard)Ø6 mm × ≥110 mm
Dimensions (H×W×D)225 × 265 × 345 mm
Net Weight~10.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelATDS-20A
Instrument TypeDual-Stage Thermal Desorber / Thermal Desorber
Primary Desorption Temperature RangeAmbient to 400 °C
Secondary Desorption Temperature Range100–400 °C
Cold Trap Temperature RangeDown to −35 °C
Desorption Recovery Rate>90%
Sample Capacity20 positions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelATD1S-20A
Price RangeUSD 1,400 – 7,000
Instrument TypeDual-stage thermal desorber
Desorption Temperature RangeAmbient to 400 °C
Cold Trap Temperature Range−30 °C to 400 °C
Desorption Recovery Rate≥95% (for C6–C12 VOCs per ISO 21045)
Sample Position Capacity20 tubes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeManufacturer
Product OriginDomestic (China)
ModelAHS-10A
Instrument TypeStatic Headspace Sampler
Automation LevelSemi-Automatic
Vial Heating RangeAmbient to 200 °C (1 °C increment)
Valve Temperature Control Range40–220 °C (±1 °C accuracy)
Sample Loop Volume1 mL
Sample Capacity12 positions
Vial Size Compatibility10 mL or 20 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelATDS-3430
Instrument TypeDual-Stage Thermal Desorber
Primary ApplicationCompliance with GB 50325-2020 for Indoor Environmental VOC Monitoring
Desorption Temperature RangeAmbient to 450 °C
Cold Trap Temperature Range−35 °C to Ambient
Desorption Recovery Rate>99% (compound-dependent)
Sample Position Capacity1 tube
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginHebei, China
Manufacturer TypeOEM Manufacturer
Instrument CategoryDomestic
ModelPT-80A
Sample Tray Capacity80 positions (40 mL VOA vials)
Injection PrecisionRSD ≤ 3%
Trap Desorption Temperature RangeAmbient to 380 °C
Cooling250 °C → 35 °C in ≤ 90 s
Purge Heater TemperatureAmbient to 95 °C
Sample Chiller TemperatureAmbient
Cold Trap Temperature Range–40 °C to ambient (Peltier + air cooling)
Purge Flow Rate0–150 mL/min
Tube Heating ZoneAmbient to 220 °C
Water Removal TrapAmbient to 400 °C
Rinse Water TemperatureAmbient to 90 °C
Solid Sample HeatingAmbient to 100 °C
Trap DimensionsQuartz, Φ4 mm × 80 mm × 1 mm wall thickness
Timing Resolution0.1 s
Max Duration100 min
Timing Accuracy< 0.1 s
Pneumatic Pressure Rating≤ 0.6 MPa
Power SupplyAC 220 V, 50 Hz
Power Consumption800 W
Dimensions (W×D×H)750 × 500 × 550 mm
Weight~50 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeStatic Headspace Sampler
Automation LevelSemi-Automatic
Sample Vial Heating RangeAmbient to 200 °C (1 °C increments)
Injection Valve Temperature Control RangeAmbient to 200 °C (1 °C increments)
Quantitative Loop Volume1 mL
Vial Capacity12 positions
Compatible Vial Sizes10 mL or 20 mL
Integrated GC Trigger OutputYes
Method Storage10 user-editable methods
Safety FeaturesOvertemperature cutoff with thermal shutdown
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0