BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelATDS-3430
Instrument TypeDual-Stage Thermal Desorber
Desorption Temperature RangeAmbient to 450 °C
Cryo-Focusing Trap Temperature Range−35 °C to Ambient
Desorption Recovery Rate>99% (compound-dependent)
Sample Position Capacity1 tube
Dimensions380 × 220 × 410 mm
Weight~15 kg
Power Consumption500 W
Temperature Control Accuracy< ±0.5 °C
RSD≤2.5% (for 0.05 μg benzene in methanol)
Second-Stage Heating Rate>3000 °C/min
Peak Width<3 s
Sample Tube CompatibilityOD ≤6.5 mm, L ≥150 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTwo-Stage Thermal Desorber
Primary Desorption Temp RangeAmbient to 450 °C
Secondary Desorption Temp Range100 to 450 °C
Cryo-Focusing Trap Temp Range−35 to Ambient °C
Desorption Recovery Rate>99% (compound-dependent)
Sample Capacity20 positions
Dimensions350 × 450 × 510 mm
Weight~40 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNorth分Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTwo-Stage Thermal Desorber
Primary Desorption Temp RangeAmbient to 400 °C
Secondary Desorption Temp Range100–400 °C
Cryo-Trap Temp RangeDown to −35 °C
Desorption Recovery Rate>90%
Sample Capacity20 positions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginShanghai, China
Manufacturer TypeOEM Manufacturer
Product CategoryDomestic
ModelATDS-3420
Instrument TypeDual-Stage Thermal Desorber
Primary Desorption Temperature RangeAmbient to 400 °C
Secondary Desorption Temperature Range100–400 °C
Cold Trap Temperature RangeDown to –35 °C
Desorption Recovery Rate>90%
Sample Capacity20 adsorption tubes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelATDS-20A
Instrument TypeDual-Stage Thermal Desorber / Thermal Desorber
Primary Desorption Temperature RangeAmbient to 400 °C
Secondary Desorption Temperature Range100–400 °C
Cold Trap Temperature RangeDown to −35 °C
Desorption Recovery Rate>90%
Sample Capacity20 positions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelATD1S-20A
Price RangeUSD 1,400 – 7,000
Instrument TypeDual-stage thermal desorber
Desorption Temperature RangeAmbient to 400 °C
Cold Trap Temperature Range−30 °C to 400 °C
Desorption Recovery Rate≥95% (for C6–C12 VOCs per ISO 21045)
Sample Position Capacity20 tubes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelATDS-3430
Instrument TypeDual-Stage Thermal Desorber
Primary ApplicationCompliance with GB 50325-2020 for Indoor Environmental VOC Monitoring
Desorption Temperature RangeAmbient to 450 °C
Cold Trap Temperature Range−35 °C to Ambient
Desorption Recovery Rate>99% (compound-dependent)
Sample Position Capacity1 tube
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Instrument TypeSingle-Stage Thermal Desorber
Primary Desorption Temperature RangeAmbient to 400 °C
Secondary Desorption / Focusing Temperature Range100–400 °C
Cold Trap Temperature RangeDown to –35 °C
Desorption Recovery Rate>90% (compound-dependent)
Sample Capacity20 adsorbent tubes
Dimensions360 × 170 × 390 mm
Weight~10 kg
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandBeifen Sanpu
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeDual-Stage Thermal Desorber
Primary Desorption Temp RangeAmbient to 450 °C
Secondary Desorption Temp Range100–450 °C
Cryotrap Temp Range−35 °C to Ambient
Desorption Recovery Rate>99% (compound-dependent)
Sample Capacity20 positions
Cold Trap Cooling MethodSolid-State Electronic Refrigeration
Temperature Control Precision±0.5 °C
RSD≤2.5% (for 0.05 μg benzene in methanol)
Sample Tube Format1/4″ OD × 3.5″ (ASTM D6196-compliant)
Valve ActuationMotor-Driven 6-Port Rotary Valve
GC InterfaceUniversal low-diffusion interface compatible with Agilent, Thermo, Shimadzu, and PerkinElmer GC/GC-MS systems]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Instrument TypeDual-Stage Thermal Desorber
Sample Position Capacity1
Desorption Temperature RangeAmbient to 400 °C (programmable)
Cold Trap Temperature Range–40 °C to –10 °C (electronic cooling)
Analyte Recovery Rate≥95% for C6–C12 VOCs
ComplianceFully compatible with GB/T 18883–2002, HJ 644–2013, ISO 16000-6, ASTM D6196
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeDual-Stage Thermal Desorber
Automation LevelSemi-Automatic
Primary Desorption Temp Range50–380 °C
Secondary Desorption Temp Range150–380 °C
Valve & Transfer Line Temp RangeAmbient to 200 °C
Cryo-Focusing Trap Temp−30 °C
Temperature Control Accuracy< ±0.1 °C
Desorption Recovery Rate> 80%
Sample Position Capacity1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic (China-Made)
ModelA'TDS-3430
Instrument TypeDual-Stage Thermal Desorber
Primary Desorption Temperature RangeAmbient to 400 °C
Secondary Desorption Temperature Range100–400 °C
Cold Trap Temperature RangeDown to –35 °C
Desorption Recovery Rate>90%
Sample Capacity20 sample tubes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTwo-Stage Thermal Desorber
Automation LevelFully Automated
Primary Desorption Temperature RangeAmbient to 450 °C (1 °C increments)
Valve Injection Zone Temperature RangeAmbient to 300 °C (1 °C increments)
Transfer Line Temperature RangeAmbient to 300 °C (1 °C increments)
Cryo-Focusing Trap Temperature Range−35 °C to ambient (1 °C increments)
Temperature Control Accuracy< ±0.5 °C
Analyte Recovery Rate>99% (compound-dependent)
Sample Capacity24 positions
Cooling Rate≤ −35 °C with rapid thermal stabilization
Secondary Desorption Ramp Rate>3000 °C/min
Carryover ReductionIntegrated valve and transfer line back-flush (0–100 mL/min, adjustable)
Calibration & ActivationOnboard tube activation protocol and simulated sampling flow control (0–160 mL/min)
PrecisionRSD ≤ 2.5% (for 0.05 μg benzene in methanol)
Sample Tube Format1/4″ OD × 3.5″ length (ASTM D6196-compliant stainless steel or quartz-lined tubes)
InterfaceMotor-driven 6-port switching valve
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandBeifen Sanpu
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeDual-Stage Thermal Desorber
Primary Desorption Temp RangeAmbient to 450 °C
Secondary Desorption Temp Range100–450 °C
Cryogenic Trap Temp Range−35 °C to Ambient
Desorption Recovery Rate>99% (compound-dependent)
Sample Capacity20 positions
Cold Trap Cooling MethodElectronic Peltier
Temperature Control Accuracy±0.5 °C
RSD≤2.5% (for 0.05 μg benzene on Tenax TA tube)
Sample Tube Format1/4″ OD × 3.5″ (ASTM D6196-compliant)
Valve ActuationMotor-driven 6-port switching valve
GC InterfaceUniversal GC inlet compatibility (split/splitless, PTV, etc.)
Dimensions350 × 450 × 510 mm (W×D×H)
Weight~40 kg]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTwo-Stage Thermal Desorber
ModelADTS-12A
Automation LevelFully Automated
Primary Desorption Temp RangeAmbient to 450 °C
Valve Injection Zone Temp RangeAmbient to 260 °C
Transfer Line Temp RangeAmbient to 450 °C
Cold Trap Temp Range−35 °C to Ambient
Temperature Control Accuracy< ±0.5 °C
Desorption Recovery Rate>99% (compound-dependent)
Sample Positions12
Cold Trap Cooling MethodSemiconductor-based Electronic Cooling
Sample Tube Format1/4″ OD × 3.5″ (ASTM D6196-compliant)
Injection MechanismMotor-driven 6-port Valving
Dimensions (L×W×H)300 × 385 × 550 mm
Weight~32 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTwo-Stage Thermal Desorber
ModelATDS-12B
Automation LevelFully Automated
Primary Desorption Temp RangeAmbient to 450 °C
Valve Injection Temp RangeAmbient to 260 °C
Transfer Line Temp RangeAmbient to 260 °C
Cold Trap Temp Range−35 °C to Ambient
Temperature Control Accuracy< ±0.5 °C
Desorption Recovery Rate>99% (compound-dependent)
Sample Capacity24 positions (dual 12-position carousel)
Cold Trap Cooling MethodSemiconductor-based Electronic Cooling
Max Heating Rate>3000 °C/min (secondary desorption zone)
RSD≤2.5% (for benzene in 0.05 μg methanol standard)
Sample Tube Format1/4″ OD × 3.5″ (ASTM D6196-compliant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTwo-Stage Thermal Desorber
Sample Position Count1
Desorption Temperature RangeAmbient to 400 °C (programmable)
Cold Trap Temperature Range–40 °C to +50 °C (cryo-cooled or Peltier-based)
Analyte Recovery Rate≥95% for C6–C12 VOCs (per ISO 16000-6 and GB/T 18883-2002)
ComplianceDesigned for GB/T 18883-2002, HJ 644-2013, ISO 16000-6, ASTM D6196
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTwo-Stage Thermal Desorber
Primary Desorption Temp RangeAmbient to 450 °C
Secondary Desorption Temp Range100–450 °C
Cold Trap Temp Range−35 °C to Ambient
Desorption Recovery Rate>99% (compound-dependent)
Sample Capacity20 positions
Cold Trap Cooling MethodElectronic Refrigeration
Temperature Control Accuracy±0.5 °C
RSD≤2.5% (for 0.05 μg benzene in methanol)
Sample Tube Format1/4″ OD × 3.5″ (ASTM D6196-compliant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTwo-Stage Thermal Desorber
Primary Desorption Temperature RangeAmbient to 450 °C
Secondary Desorption (Flash) Temperature Range100–450 °C
Cryo-Focusing Trap Temperature Range−35 °C to Ambient
Desorption Recovery Rate>99% (compound-dependent)
Sample Capacity20 positions
Cold Trap Cooling MethodElectronic Peltier Cooling
Temperature Control Accuracy±0.5 °C
RSD≤2.5% (for 0.05 μg benzene in methanol)
Sample Tube Specification1/4″ OD × 3.5″ (ASTM D6196-compliant)
Valve ActuationMotor-driven 6-port switching valve
GC SynchronizationTTL-level trigger output for GC start and data system
Power SupplyAC 220 V ±10%, 50 Hz
Dimensions (W×D×H)350 × 450 × 510 mm
Weight~40 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelATDS-40A
Instrument TypeTwo-Stage Thermal Desorber
Automation LevelFully Automated
Primary Desorption Temperature RangeAmbient to 450 °C (1 °C increments)
Valve Injection Zone Temperature RangeAmbient to 300 °C (1 °C increments)
Transfer Line Temperature RangeAmbient to 300 °C (1 °C increments, 24 V low-voltage heating)
Secondary Desorption Temperature RangeAmbient to 450 °C (1 °C increments)
Cryo-Focusing Trap Temperature Range−35 °C to Ambient (1 °C increments
Temperature Control Accuracy< ±0.5 °C
Desorption Recovery Rate>99% (compound-dependent)
Sample Capacity40 positions
Sample Tube Specification1/4″ OD × 3.5″ length (ASTM D6196-compliant)
Carryover MitigationAutomated back-flush of valve and transfer line (0–100 mL/min, continuously adjustable)
Quantitative ReproducibilityRSD ≤2.5% (benzene at 0.05 μg in methanol)
Enrichment Time0–60 min
Injection Time0–60 min
Simulated Sampling Flow0–160 mL/min (continuously adjustable)
Dimensions350 × 450 × 550 mm (W × D × H)
Weight~45 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Instrument TypeTwo-stage Thermal Desorber
Primary Desorption Temp RangeAmbient to 400 °C
Secondary Desorption Temp Range100–400 °C
Cold Trap Temp RangeDown to –35 °C
Desorption Recovery Rate>90%
Sample Capacity20 tubes
Tube Format1/4″ OD × 3.5″ (ASTM D6196-compliant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
ModelHP-6900N
Instrument TypeDual-Stage Thermal Desorber
Desorption Temperature RangeAmbient to 350 °C
Cold Trap Temperature Range−35 °C to Ambient (1 °C increments)
Temperature Control Accuracy< ±0.5 °C
Sample Loop CapacityNot Applicable (Direct Air Sampling System)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Sanpu
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelAutoTDS-III
Instrument TypeDual-Stage Thermal Desorber / Thermal Desorber
Automation LevelSemi-Automatic
Primary Desorption Temp Range50–380 °C
Cold Trap Temp Range−30 °C (electronic Peltier cooling)
Secondary Desorption Temp Range150–380 °C
Secondary Desorption Ramp Rate>1800 °C/min
Valve & Transfer Line Temp RangeRoom Temp to 200 °C
Temperature Control Accuracy<±0.1 °C
Desorption Recovery Rate≥90%
Sample Position Capacity1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSanpu
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTwo-Stage Thermal Desorber
Primary Desorption Temp RangeAmbient to 450 °C
Secondary Desorption Temp Range100 to 450 °C
Cryo-Focusing Trap Temp Range−35 to Ambient °C
Desorption Recovery Rate>99% (compound-dependent)
Sample Capacity20 positions
Cold Trap Cooling MethodElectronic Peltier Cooling
Temperature Control Accuracy±0.5 °C
RSD≤2.5% (for 0.05 μg benzene in methanol)
Sample Tube Format1/4″ OD × 3.5″ (ASTM D6196-compliant)
Valve ActuationMotor-driven 6-port switching valve
Dimensions (L×W×H)350 × 450 × 510 mm
Weight~40 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0