- All
- Favorite
- Popular
- Most rated
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BG-8205 |
| Power Supply | AC 220 V |
| Power Consumption | 250 W |
| Load on Specimen | 26.7 ± 0.2 N |
| Rubber Wheel Rotational Speed | 76 ± 2 rpm |
| Abrasive Wheel Rotational Speed | 34 ± 1 rpm |
| Adjustable Inclination Angle Between Wheels | 15° or 25° |
| Dimensions (L×W×H) | 600 × 480 × 400 mm |
| Net Weight | 60 kg |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | BQS |
| Price Range | USD 1,400 – 2,800 |
| Power Supply | 100–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 9000 mbar (145 psi) |
| Min Inlet Pressure | 4000 mbar (58 psi) |
| Dimensions | 400 × 380 × 335 mm (W × D × H) |
| Test Pressure Range | 100–8000 mbar (1.5–116 psi) |
| Accuracy | Net Volume Test ±4% |
| Environmental Conditions | 15–35 °C |
| Test Duration | Net Volume Test 5±2 min |
| Water Intrusion Test | Set Time + 5±2 min |
| Display | 5.7″ backlit monochrome LCD |
| Data Interface | RS232 serial port |
| Language Options | English / Chinese |
| Storage Capacity | 500 test records (incl. curves) |
| Print Output | Dot-matrix printer (Chinese/English), full parameter + result + curve |
| Sample Compatibility | Disc membranes Φ25–Φ300 mm |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BQS-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Test Pressure | 6900 mbar (sensor customizable) |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 10–80% RH |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7-inch color touchscreen, 256-color, GUI in English/Chinese |
| Data Storage | 32 GB internal, ≥1 million test records |
| Print Output | Thermal printer, bilingual (English/Chinese), includes test parameters, results, and pressure decay curves |
| Test Duration | Bubble Point: 2 ± 2 min |
| Diffusion Flow | 7 ± 2 min |
| Water Intrusion | 7 ± 2 min |
| System Leak Check | 3 ± 1 min |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | B121 |
| Price | USD 1,200 (FOB Beijing) |
| Compliance | GB/T 1410–2006 / IEC 60093:1980 |
| Measurement Principle | Guarded Three-Electrode Ring Method |
| Resistance Range | 1.0×10³ – 2.0×10¹² Ω |
| Resistivity Range | 1.0×10³ – 2.0×10¹² Ω·m |
| Sheet Resistance Range | 1.0×10⁴ – 2.0×10¹² Ω/□ |
| Resolution | 0.1×10³ – 0.1×10¹² Ω (auto-ranging) |
| Power Supply | 220 V ±10%, 50 Hz ±4%, ≤20 W |
| Dimensions (W×H×L) | 280 × 90 × 275 mm |
| Net Weight | ≤3.0 kg |
| Standard Electrode | Triple-ring coaxial electrode (center cylinder Ø50 mm × 40 mm h |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BQS-19 Series |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Test Duration (Bubble Point) | 2 ± 2 min |
| Test Duration (Diffusion Flow / Water Intrusion) | 7 ± 2 min |
| System Leak Test Time | 3 ± 1 min |
| Display | 5.7-inch 32-bit touchscreen |
| Data Storage | 32 GB (≥1 million records) |
| Interface | RS232/USB/Ethernet for PC connectivity |
| Compliance Support | FDA 21 CFR Part 11 (audit trail enabled), GMP/GLP-ready |
| Language Options | English & Chinese |
| Dimensions | 500 × 200 × 180 mm (L×W×H) |
| Environmental Operating Range | 0–50 °C, 10–80% RH |
| Key | Brand: All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BG-8005 |
| Pricing | Upon Request |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BQS-19+ |
| Power Supply | 100–240 V AC, 50/60 Hz, ≤100 W |
| Max Operating Pressure | 9999 mbar |
| Min Inlet Pressure | 4000 mbar |
| Pressure Range for Testing | 100–8000 mbar (1.5–116 psi) |
| Bubble Point Accuracy | ±50 mbar |
| Diffusion Flow Accuracy | ±4% |
| Net Volume Test Accuracy | ±4% |
| Test Duration (Bubble Point) | 15 ± 2 min |
| Test Duration (Enhanced Bubble Point) | 20 ± 2 min |
| Test Duration (Diffusion Flow) | 10 ± 2 min |
| Display | 5.7" monochrome TFT LCD |
| Interface | RS232 serial port |
| Data Storage | 500 test records (configurable extension via PC connection) |
| Environmental Operating Conditions | 5–35 °C, 10–80% RH |
| Dimensions (W × D × H1 × H2) | 400 × 380 × 100 × 235 mm |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BC-50KV |
| Output Voltage Range | AC/DC 0–50 kV |
| Rated Capacity | 5 kVA |
| Voltage Accuracy | ≤1% |
| Rise Rate Adjustment | 0.1–5.0 kV/s (continuously variable) |
| Test Modes | AC/DC stepwise ramp, constant-rate ramp, and hold-at-level withstand testing |
| Short-Circuit Response Time | ≤0.05 s |
| Leakage Current Measurement Range | 0–200 mA (real-time, mA-resolution) |
| Electrode Set per GB/T 1408.1–2006 | Two Φ25 mm × 25 mm |
| Test Mediums | Air or insulating oil |
| Compliance Standards | IEC 60243-1, ASTM D149, GB/T 1408.1–2006, UL 508, CSA C22.2 No. 0.3 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WYZ-240 |
| Price | USD 2,800 (FOB Beijing) |
| Max Cutting Width | 300 mm |
| Max Cutting Thickness | 15 mm |
| Max Milling Length (Flat/Dumbbell) | 300 mm |
| Cutting Wheel Dimensions | 200 × 32 × 2 mm |
| Notch Milling Tool Length | 50 mm |
| Dumbbell/Flat Milling Tool Dimensions | 30 × 12 × 30 mm |
| Overall Dimensions | 1130 × 720 × 950 mm |
| Spindle Speeds | Cutting Section: 1400–2800 rpm |
| Notch Milling Section | 400 rpm |
| Dumbbell/Flat Milling Section | Low-Speed: 470 / 940 rpm |
| High-Speed | 715 / 1430 rpm |
| Motor Power | Notch Milling Motor: 550 W |
| Dumbbell/Flat Milling Motor | 0.8–1.3 kW |
| Cutting Motor | 0.8 kW |
| Cooling Oil Pump Motor | 60 W |
| Auto-Feed Motor (Flat/Dumbbell) | 60 W |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BRXZZ |
| Price | USD 3,500 (FOB Beijing) |
| Temperature Range | Ambient to 400 °C |
| Temperature Stability | ±0.1 °C |
| Temp. Recovery Time | < 4 min |
| Cut Count | 1–99 |
| Cut Interval | 10–600 s |
| Continuous Operation | >10,000 h |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Die Diameter | Φ2.095 ±0.005 mm |
| Die Length | 8.000 ±0.025 mm |
| Barrel ID | Φ9.550 ±0.025 mm |
| Barrel Length | 152.0 ±0.1 mm |
| Piston Head Diameter | 9.475 ±0.015 mm |
| Piston Head Length | 6.350 ±0.100 mm |
| Standard Loads (8 levels) | 0.325 kg (3.187 N) to 21.600 kg (211.82 N) |
| [Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BSQ-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar (customizable sensor) |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7-inch color TFT touchscreen, 256-color, GUI in English/Chinese |
| Data Storage | 32 GB internal flash memory (≥1,000,000 test records) |
| Test Duration | Bubble Point: 2 ± 2 min |
| Diffusion Flow | 7 ± 2 min |
| Water Intrusion | 7 ± 2 min |
| System Leak Check | 3 ± 1 min |
| Environmental Operating Range | 0–50 °C, 10–80% RH |
| Compliance | Fully supports GMP documentation requirements, audit trail-ready configuration, user-level access control (Operator/Supervisor/Admin), 21 CFR Part 11–compatible data handling with electronic signature support] |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BWR |
| Power Supply | AC 220 V ±10%, 50 Hz, 30 A |
| Heating Power | 2.5 kW |
| Heating Medium | Methyl Silicone Oil (flash point ≥300 °C, kinematic viscosity 200 cSt, 20 L required) |
| Sample Stands | Three independent test stations per bath |
| Deformation Measurement | Linear encoder-based dial indicator (resolution 0.001 mm, accuracy ±0.01 mm) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.01 °C |
| Heating Rates | 120 ±5 °C/h (12 ±1 °C/6 min) or 50 ±3 °C/h (5 ±0.5 °C/6 min) |
| Deformation Range | −0.1 to 5.0 mm |
| Cooling Method | Natural convection above 150 °C |
| Maximum Settable Temperature | 300 °C with over-temperature cut-off |
| Load Rod + Indenter Mass | 88 g |
| Standard Loads | Vicat GA = 10.0 N ±0.2 N (1000 g), GB = 50.0 N ±1.0 N (5000 g) |
| HDT fiber stress options | 0.45 MPa (Method B), 1.80 MPa (Method A), 8.00 MPa (Method C) |
| Compliance | ASTM D1525, ASTM D648, ISO 306:2004, ISO 75-1:2013, GB/T 1633–2000, GB/T 1634.1–2004, GB 8802 |
| Key | Brand: All Precision Instrument |
|---|---|
| Model | BQS-19 |
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Min Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7″ color touchscreen (256 colors), GUI in English/Chinese |
| Operating Environment | 0–50 °C, 10–80% RH |
| Data Storage | 32 GB internal (≥1 million test records) |
| Communication Interface | RS232/USB/Ethernet (with PC software for remote control & audit trail) |
| Compliance | Designed to support GMP, FDA 21 CFR Part 11, and ISO 13408-2 requirements |
| Test Modes | Bubble Point, Diffusion Flow, Water Intrusion |
| Typical Test Duration | Bubble Point (2 ± 2 min), Diffusion Flow (7 ± 2 min), Water Intrusion (7 ± 2 min), System Leak Check (3 ± 1 min) |
| Printing | Integrated thermal printer (bilingual report with test parameters, results, and real-time curve) |
| Brand | All Precision Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | S-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7-inch color TFT touchscreen, 256-color, GUI in English/Chinese |
| Data Storage | 32 GB internal flash memory (≥1 million test records) |
| Communication Interface | RS232/USB/Ethernet for PC connectivity and remote supervision |
| Compliance | Designed to support GMP, FDA 21 CFR Part 11 (audit trail ready), ISO 13408-2, ASTM F838, USP <1207> |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BQS-40 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Maximum Operating Pressure | 7999 mbar |
| Inlet Gas Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (L×W×H) | 500 × 200 × 180 mm |
| Display | 5.7-inch 32-bit touchscreen |
| Language Options | English / Chinese |
| Data Storage | 32 GB (≥1 million test records) |
| Compliance | CE certified, FDA 21 CFR Part 11 compliant architecture, GMP-aligned audit trail |
| Enclosure Rating | IP54 |
| Supported Test Methods | Bubble Point, Diffusion Flow, Pressure Hold (Decay), Water Intrusion |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BEST-121 |
| Test Voltage Range | DC 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V |
| Resistance Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Measurement Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Volume Resistivity Range | 1.0×10³ Ω·m to 2.0×10¹² Ω·m |
| Surface Resistivity Range | 1.0×10⁴ Ω/□ to 2.0×10¹² Ω/□ |
| Resolution | 0.1×10³ Ω to 0.1×10¹² Ω (adjustable across 1–2 decades) |
| Power Supply | AC 220 V ±10%, 50 Hz ±4%, ≤20 W |
| Dimensions (W×H×L) | 280 mm × 90 mm × 275 mm |
| Net Weight | ≤3.0 kg |
| Compliance | GB/T 1410–2006 / IEC 60093:1980 |
| Key | Brand: North Guang Precision Instrument |
|---|---|
| Model | BG-8121 |
| Drum Diameter | 150 ± 0.2 mm |
| Drum Length | 460 mm |
| Drum Speed | 40 ± 1 rpm |
| Specimen Dimensions | Ø16 ± 0.2 mm × ≥6 mm thick |
| Traverse Speed | 4.2 ± 0.06 mm/rev |
| Abrasion Travel | 20 m or 40 m |
| Specimen Load Options | 2.5 N (dead weight), 5–20 N (adjustable in 2.5 N increments) |
| Power Supply | AC 220 V, 50 Hz |
| Motor Speed | 3000 rpm |
| Compliance | GB/T 9867–1988, ISO 4649:2006, DIN 53516:1987 |
| Brand | North Guang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CZF-5 |
| Price | USD 1,700 (FOB Beijing) |
| Burner Tip ID | 9.5 mm ± 0.3 mm |
| Burner Length | 100 mm ± 10 mm |
| Flame Angle Adjustment | 0–45° (manual, calibrated scale) |
| Ignition Support | Medical-grade cotton pad |
| Fuel Gas | 98% methane (calibrated), or natural gas (37 MJ/m³ ± 1 MJ/m³), or propane |
| Flame Temperature Ramp | 100°C ± 5°C to 700°C ± 3°C in 44 s ± 2.0 s or 54 s ± 2.0 s (verified with thermal calibration kit) |
| Calibration Kit Options | φ5.5 mm Cu slug (1.76 ± 0.01 g) or φ9 mm Cu slug (10.00 ± 0.05 g), imported controller |
| Thermocouple | K-type, insulated, high-temp armored, Ø0.5 mm |
| Timing Range | 1.0 s – 999.9 s (digital presettable) |
| Repetition Cycles | 1 – 9999 (digital presettable) |
| Chamber Volume | 0.75 m³ (optional: 0.5 m³ or 1.0 m³) |
| External Dimensions | 1330 mm (W) × 730 mm (D) × 1500 mm (H) |
| Enclosure Material | Powder-coated steel plate |
| Exhaust Port | Ø100 mm |
| Power Supply | AC 220 V, 50 Hz, 5 A |
| Brand | North Guang Precision Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BEST-121 |
| Test Voltage Range | DC 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V |
| Resistance Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Measurement Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Accuracy | ±1% (10⁴–10⁹ Ω), ±5% + 2 digits (10¹⁰–10¹¹ Ω), ±5% + 5 digits (10¹²–10¹³ Ω), ±10–15% + 5 digits (>10¹⁴ Ω) |
| Compliance | GB 4386-84, GB 6650-86, GB 1410, GB 10580 |
| Brand | North Guang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BG-8102 |
| Quotation | Upon Request |
| Stroke Range | 0–100 mm |
| Worktable Dimensions | 245 mm × 245 mm |
| Overall Dimensions | 420 mm × 360 mm × 580 mm |
| Operating Air Pressure | 0.4 MPa |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | BP-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (L×W×H) | 500 × 200 × 180 mm |
| Display | 5.7-inch 32-bit touchscreen |
| Language Options | English / Chinese |
| Data Storage | 32 GB (≥1 million test records) |
| Print Output | Bilingual (English/Chinese), including test parameters, results, and pressure decay curves |
| Environmental Operating Conditions | 0–50 °C, 10–80% RH |
| Test Duration | Bubble point: 2 ± 2 min |
| Diffusion flow | 7 ± 2 min |
| Water intrusion | 7 ± 2 min |
| System leak check | 3 ± 1 min |
| Communication Interface | RS232/USB for PC connectivity and remote supervision via proprietary software |
| Compliance Support | Fully compatible with FDA 21 CFR Part 11 audit trail requirements, EU Annex 1, USP <1207>, ISO 13408-2, and GMP Annex 15 integrity testing protocols |
Show next