BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelBG-8205
Power SupplyAC 220 V
Power Consumption250 W
Load on Specimen26.7 ± 0.2 N
Rubber Wheel Rotational Speed76 ± 2 rpm
Abrasive Wheel Rotational Speed34 ± 1 rpm
Adjustable Inclination Angle Between Wheels15° or 25°
Dimensions (L×W×H)600 × 480 × 400 mm
Net Weight60 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelBQS
Price RangeUSD 1,400 – 2,800
Power Supply100–240 V AC, 50/60 Hz, 100 W
Max Operating Pressure9000 mbar (145 psi)
Min Inlet Pressure4000 mbar (58 psi)
Dimensions400 × 380 × 335 mm (W × D × H)
Test Pressure Range100–8000 mbar (1.5–116 psi)
AccuracyNet Volume Test ±4%
Environmental Conditions15–35 °C
Test DurationNet Volume Test 5±2 min
Water Intrusion TestSet Time + 5±2 min
Display5.7″ backlit monochrome LCD
Data InterfaceRS232 serial port
Language OptionsEnglish / Chinese
Storage Capacity500 test records (incl. curves)
Print OutputDot-matrix printer (Chinese/English), full parameter + result + curve
Sample CompatibilityDisc membranes Φ25–Φ300 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelBQS-19
Power Supply170–240 V AC, 50/60 Hz, 100 W
Max Test Pressure6900 mbar (sensor customizable)
Pressure Sensitivity±1.0 mbar
Bubble Point Accuracy±60 mbar
Operating Temperature0–50 °C
Relative Humidity10–80% RH
Dimensions (W×D×H)240 × 320 × 260 mm
Display5.7–7-inch color touchscreen, 256-color, GUI in English/Chinese
Data Storage32 GB internal, ≥1 million test records
Print OutputThermal printer, bilingual (English/Chinese), includes test parameters, results, and pressure decay curves
Test DurationBubble Point: 2 ± 2 min
Diffusion Flow7 ± 2 min
Water Intrusion7 ± 2 min
System Leak Check3 ± 1 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelB121
PriceUSD 1,200 (FOB Beijing)
ComplianceGB/T 1410–2006 / IEC 60093:1980
Measurement PrincipleGuarded Three-Electrode Ring Method
Resistance Range1.0×10³ – 2.0×10¹² Ω
Resistivity Range1.0×10³ – 2.0×10¹² Ω·m
Sheet Resistance Range1.0×10⁴ – 2.0×10¹² Ω/□
Resolution0.1×10³ – 0.1×10¹² Ω (auto-ranging)
Power Supply220 V ±10%, 50 Hz ±4%, ≤20 W
Dimensions (W×H×L)280 × 90 × 275 mm
Net Weight≤3.0 kg
Standard ElectrodeTriple-ring coaxial electrode (center cylinder Ø50 mm × 40 mm h
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelBQS-19 Series
Power Supply170–240 V AC, 50/60 Hz, 100 W
Max Operating Pressure7999 mbar
Minimum Inlet Pressure3000 mbar
Test Pressure Range500–6900 mbar
Pressure Sensitivity±1.0 mbar
Bubble Point Accuracy±60 mbar
Test Duration (Bubble Point)2 ± 2 min
Test Duration (Diffusion Flow / Water Intrusion)7 ± 2 min
System Leak Test Time3 ± 1 min
Display5.7-inch 32-bit touchscreen
Data Storage32 GB (≥1 million records)
InterfaceRS232/USB/Ethernet for PC connectivity
Compliance SupportFDA 21 CFR Part 11 (audit trail enabled), GMP/GLP-ready
Language OptionsEnglish & Chinese
Dimensions500 × 200 × 180 mm (L×W×H)
Environmental Operating Range0–50 °C, 10–80% RH
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: All Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelBG-8005
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelBQS-19+
Power Supply100–240 V AC, 50/60 Hz, ≤100 W
Max Operating Pressure9999 mbar
Min Inlet Pressure4000 mbar
Pressure Range for Testing100–8000 mbar (1.5–116 psi)
Bubble Point Accuracy±50 mbar
Diffusion Flow Accuracy±4%
Net Volume Test Accuracy±4%
Test Duration (Bubble Point)15 ± 2 min
Test Duration (Enhanced Bubble Point)20 ± 2 min
Test Duration (Diffusion Flow)10 ± 2 min
Display5.7" monochrome TFT LCD
InterfaceRS232 serial port
Data Storage500 test records (configurable extension via PC connection)
Environmental Operating Conditions5–35 °C, 10–80% RH
Dimensions (W × D × H1 × H2)400 × 380 × 100 × 235 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBC-50KV
Output Voltage RangeAC/DC 0–50 kV
Rated Capacity5 kVA
Voltage Accuracy≤1%
Rise Rate Adjustment0.1–5.0 kV/s (continuously variable)
Test ModesAC/DC stepwise ramp, constant-rate ramp, and hold-at-level withstand testing
Short-Circuit Response Time≤0.05 s
Leakage Current Measurement Range0–200 mA (real-time, mA-resolution)
Electrode Set per GB/T 1408.1–2006Two Φ25 mm × 25 mm
Test MediumsAir or insulating oil
Compliance StandardsIEC 60243-1, ASTM D149, GB/T 1408.1–2006, UL 508, CSA C22.2 No. 0.3
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelWYZ-240
PriceUSD 2,800 (FOB Beijing)
Max Cutting Width300 mm
Max Cutting Thickness15 mm
Max Milling Length (Flat/Dumbbell)300 mm
Cutting Wheel Dimensions200 × 32 × 2 mm
Notch Milling Tool Length50 mm
Dumbbell/Flat Milling Tool Dimensions30 × 12 × 30 mm
Overall Dimensions1130 × 720 × 950 mm
Spindle SpeedsCutting Section: 1400–2800 rpm
Notch Milling Section400 rpm
Dumbbell/Flat Milling SectionLow-Speed: 470 / 940 rpm
High-Speed715 / 1430 rpm
Motor PowerNotch Milling Motor: 550 W
Dumbbell/Flat Milling Motor0.8–1.3 kW
Cutting Motor0.8 kW
Cooling Oil Pump Motor60 W
Auto-Feed Motor (Flat/Dumbbell)60 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelBRXZZ
PriceUSD 3,500 (FOB Beijing)
Temperature RangeAmbient to 400 °C
Temperature Stability±0.1 °C
Temp. Recovery Time< 4 min
Cut Count1–99
Cut Interval10–600 s
Continuous Operation>10,000 h
Power SupplyAC 220 V ±10%, 50 Hz
Die DiameterΦ2.095 ±0.005 mm
Die Length8.000 ±0.025 mm
Barrel IDΦ9.550 ±0.025 mm
Barrel Length152.0 ±0.1 mm
Piston Head Diameter9.475 ±0.015 mm
Piston Head Length6.350 ±0.100 mm
Standard Loads (8 levels)0.325 kg (3.187 N) to 21.600 kg (211.82 N)
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBSQ-19
Power Supply170–240 V AC, 50/60 Hz, 100 W
Max Operating Pressure7999 mbar
Minimum Inlet Pressure3000 mbar
Test Pressure Range500–6900 mbar (customizable sensor)
Pressure Sensitivity±1.0 mbar
Bubble Point Accuracy±60 mbar
Dimensions (W×D×H)240 × 320 × 260 mm
Display5.7–7-inch color TFT touchscreen, 256-color, GUI in English/Chinese
Data Storage32 GB internal flash memory (≥1,000,000 test records)
Test DurationBubble Point: 2 ± 2 min
Diffusion Flow7 ± 2 min
Water Intrusion7 ± 2 min
System Leak Check3 ± 1 min
Environmental Operating Range0–50 °C, 10–80% RH
ComplianceFully supports GMP documentation requirements, audit trail-ready configuration, user-level access control (Operator/Supervisor/Admin), 21 CFR Part 11–compatible data handling with electronic signature support]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelBWR
Power SupplyAC 220 V ±10%, 50 Hz, 30 A
Heating Power2.5 kW
Heating MediumMethyl Silicone Oil (flash point ≥300 °C, kinematic viscosity 200 cSt, 20 L required)
Sample StandsThree independent test stations per bath
Deformation MeasurementLinear encoder-based dial indicator (resolution 0.001 mm, accuracy ±0.01 mm)
Temperature Accuracy±0.5 °C
Temperature Resolution0.01 °C
Heating Rates120 ±5 °C/h (12 ±1 °C/6 min) or 50 ±3 °C/h (5 ±0.5 °C/6 min)
Deformation Range−0.1 to 5.0 mm
Cooling MethodNatural convection above 150 °C
Maximum Settable Temperature300 °C with over-temperature cut-off
Load Rod + Indenter Mass88 g
Standard LoadsVicat GA = 10.0 N ±0.2 N (1000 g), GB = 50.0 N ±1.0 N (5000 g)
HDT fiber stress options0.45 MPa (Method B), 1.80 MPa (Method A), 8.00 MPa (Method C)
ComplianceASTM D1525, ASTM D648, ISO 306:2004, ISO 75-1:2013, GB/T 1633–2000, GB/T 1634.1–2004, GB 8802
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: All Precision Instrument
ModelBQS-19
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Power Supply170–240 V AC, 50/60 Hz, 100 W
Max Operating Pressure7999 mbar
Min Inlet Pressure3000 mbar
Test Pressure Range500–6900 mbar
Pressure Sensitivity±1.0 mbar
Bubble Point Accuracy±60 mbar
Dimensions (W×D×H)240 × 320 × 260 mm
Display5.7–7″ color touchscreen (256 colors), GUI in English/Chinese
Operating Environment0–50 °C, 10–80% RH
Data Storage32 GB internal (≥1 million test records)
Communication InterfaceRS232/USB/Ethernet (with PC software for remote control & audit trail)
ComplianceDesigned to support GMP, FDA 21 CFR Part 11, and ISO 13408-2 requirements
Test ModesBubble Point, Diffusion Flow, Water Intrusion
Typical Test DurationBubble Point (2 ± 2 min), Diffusion Flow (7 ± 2 min), Water Intrusion (7 ± 2 min), System Leak Check (3 ± 1 min)
PrintingIntegrated thermal printer (bilingual report with test parameters, results, and real-time curve)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelS-19
Power Supply170–240 V AC, 50/60 Hz, 100 W
Max Operating Pressure7999 mbar
Minimum Inlet Pressure3000 mbar
Test Pressure Range500–6900 mbar
Pressure Sensitivity±1.0 mbar
Bubble Point Accuracy±60 mbar
Dimensions (W×D×H)240 × 320 × 260 mm
Display5.7–7-inch color TFT touchscreen, 256-color, GUI in English/Chinese
Data Storage32 GB internal flash memory (≥1 million test records)
Communication InterfaceRS232/USB/Ethernet for PC connectivity and remote supervision
ComplianceDesigned to support GMP, FDA 21 CFR Part 11 (audit trail ready), ISO 13408-2, ASTM F838, USP <1207>
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBQS-40
Power Supply170–240 V AC, 50/60 Hz, 100 W
Maximum Operating Pressure7999 mbar
Inlet Gas Pressure3000 mbar
Test Pressure Range500–6900 mbar
Pressure Sensitivity±1.0 mbar
Bubble Point Accuracy±60 mbar
Dimensions (L×W×H)500 × 200 × 180 mm
Display5.7-inch 32-bit touchscreen
Language OptionsEnglish / Chinese
Data Storage32 GB (≥1 million test records)
ComplianceCE certified, FDA 21 CFR Part 11 compliant architecture, GMP-aligned audit trail
Enclosure RatingIP54
Supported Test MethodsBubble Point, Diffusion Flow, Pressure Hold (Decay), Water Intrusion
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBEST-121
Test Voltage RangeDC 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V
Resistance Measurement Range1×10⁴ Ω to 1×10¹⁸ Ω
Current Measurement Range2×10⁻⁴ A to 1×10⁻¹⁶ A
Volume Resistivity Range1.0×10³ Ω·m to 2.0×10¹² Ω·m
Surface Resistivity Range1.0×10⁴ Ω/□ to 2.0×10¹² Ω/□
Resolution0.1×10³ Ω to 0.1×10¹² Ω (adjustable across 1–2 decades)
Power SupplyAC 220 V ±10%, 50 Hz ±4%, ≤20 W
Dimensions (W×H×L)280 mm × 90 mm × 275 mm
Net Weight≤3.0 kg
ComplianceGB/T 1410–2006 / IEC 60093:1980
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: North Guang Precision Instrument
ModelBG-8121
Drum Diameter150 ± 0.2 mm
Drum Length460 mm
Drum Speed40 ± 1 rpm
Specimen DimensionsØ16 ± 0.2 mm × ≥6 mm thick
Traverse Speed4.2 ± 0.06 mm/rev
Abrasion Travel20 m or 40 m
Specimen Load Options2.5 N (dead weight), 5–20 N (adjustable in 2.5 N increments)
Power SupplyAC 220 V, 50 Hz
Motor Speed3000 rpm
ComplianceGB/T 9867–1988, ISO 4649:2006, DIN 53516:1987
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNorth Guang Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelCZF-5
PriceUSD 1,700 (FOB Beijing)
Burner Tip ID9.5 mm ± 0.3 mm
Burner Length100 mm ± 10 mm
Flame Angle Adjustment0–45° (manual, calibrated scale)
Ignition SupportMedical-grade cotton pad
Fuel Gas98% methane (calibrated), or natural gas (37 MJ/m³ ± 1 MJ/m³), or propane
Flame Temperature Ramp100°C ± 5°C to 700°C ± 3°C in 44 s ± 2.0 s or 54 s ± 2.0 s (verified with thermal calibration kit)
Calibration Kit Optionsφ5.5 mm Cu slug (1.76 ± 0.01 g) or φ9 mm Cu slug (10.00 ± 0.05 g), imported controller
ThermocoupleK-type, insulated, high-temp armored, Ø0.5 mm
Timing Range1.0 s – 999.9 s (digital presettable)
Repetition Cycles1 – 9999 (digital presettable)
Chamber Volume0.75 m³ (optional: 0.5 m³ or 1.0 m³)
External Dimensions1330 mm (W) × 730 mm (D) × 1500 mm (H)
Enclosure MaterialPowder-coated steel plate
Exhaust PortØ100 mm
Power SupplyAC 220 V, 50 Hz, 5 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNorth Guang Precision Instruments
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBEST-121
Test Voltage RangeDC 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V
Resistance Measurement Range1×10⁴ Ω to 1×10¹⁸ Ω
Current Measurement Range2×10⁻⁴ A to 1×10⁻¹⁶ A
Accuracy±1% (10⁴–10⁹ Ω), ±5% + 2 digits (10¹⁰–10¹¹ Ω), ±5% + 5 digits (10¹²–10¹³ Ω), ±10–15% + 5 digits (>10¹⁴ Ω)
ComplianceGB 4386-84, GB 6650-86, GB 1410, GB 10580
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNorth Guang Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelBG-8102
QuotationUpon Request
Stroke Range0–100 mm
Worktable Dimensions245 mm × 245 mm
Overall Dimensions420 mm × 360 mm × 580 mm
Operating Air Pressure0.4 MPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
ModelBP-19
Power Supply170–240 V AC, 50/60 Hz, 100 W
Max Operating Pressure7999 mbar
Minimum Inlet Pressure3000 mbar
Test Pressure Range500–6900 mbar
Pressure Sensitivity±1.0 mbar
Bubble Point Accuracy±60 mbar
Dimensions (L×W×H)500 × 200 × 180 mm
Display5.7-inch 32-bit touchscreen
Language OptionsEnglish / Chinese
Data Storage32 GB (≥1 million test records)
Print OutputBilingual (English/Chinese), including test parameters, results, and pressure decay curves
Environmental Operating Conditions0–50 °C, 10–80% RH
Test DurationBubble point: 2 ± 2 min
Diffusion flow7 ± 2 min
Water intrusion7 ± 2 min
System leak check3 ± 1 min
Communication InterfaceRS232/USB for PC connectivity and remote supervision via proprietary software