Empowering Scientific Discovery

Beijing Beiguang Jingyi Instrument & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBG-400A1
Internal Dimensions (W×D×H)450 × 450 × 500 mm
Temperature Range10–300 °C
Temperature Uniformity±1 °C
Humidity RangeNot Applicable (Dry Heat / UV Only)
UV Wavelength340 nm (UVA-340 lamp standard)
Black Panel Temperature Range40–80 °C (adjustable per test protocol)
Irradiance Control0.63–1.25 W/m² @ 340 nm
Chamber Volume100 L
Heating Power2000 W
Power Supply220 V AC, 50/60 Hz
ComplianceGB/T 2951.12–2008, ASTM G154, ISO 4892-3, IEC 60068-2-5
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
ModelBU-800A
OriginBeijing, China
Manufacturer TypeOEM/ODM Producer
Power Supply220 V ±5%, 50 Hz, 2 kW
UV Lamp Configuration16 × 20 W low-pressure mercury lamps (253.7 nm peak output)
Conveyor Speed0–5 m/min (infinitely variable, digital display)
Tunnel Dimensions2000 mm (L) × 500 mm (W) × 200–300 mm (H, adjustable inlet/outlet height)
UV Exposure Zone1000 mm
Construction Material304 stainless steel (outer shell: 1.2 mm
inner reflective chamber1.0 mm mirror-finish #2B)
Conveyor BeltBlack PTFE-coated mesh belt
Safety FeaturesLight-shielded entry/exit zones with adjustable baffles, overvoltage/overcurrent protection, real-time lamp hour counter, fault alarm indication
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelBWD-D
Temperature Control RangeAmbient to –70 °C (ambient ≤25 °C)
Temperature Stability±0.3 °C
Cooling Rate~2.5 °C/min (0 °C to –30 °C)
Internal Chamber Dimensions280 × 170 × 120 mm (L×W×H)
External Dimensions900 × 500 × 800 mm (L×W×H)
Sample Capacity1 test fixture (4 rubber specimens or 15 plastic specimens per test cycle)
Timer Range0–99 min, 1-s resolution
Cooling MediumEthanol or other non-freezing liquid
Stirring Motor Power8 W
Power Supply220–240 V AC, 50 Hz, 1.5 kW
Operating Ambient Limit≤25 °C
Impact Head Radius1.6 ± 0.1 mm
Impact Gap (head to specimen holder)6.4 ± 0.3 mm
Horizontal Offset (impact centerline to holder centerline)8 ± 0.3 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeCapillary Rheometer
ModelBML-400-B
Maximum Load Capacity25 kN
Temperature Range50–450 °C
Temperature Accuracy±0.1 °C (chamber), ±0.2 °C (barrel)
Barrel Diameter Options9.5, 12, 15 mm (custom lengths available)
Piston Speed Range0.0005–20 mm/s
Dynamic Speed Ratio1:40,000
Pressure Sensor RangeUp to 2000 bar
Pressure Accuracy< ±0.25% FS
Capillary DiesFive standard options (e.g., 5/0.5-L=5 mm/D=0.5 mm
Die MaterialTungsten carbide
Barrel & Piston MaterialNitrided stainless steel
Control ModeConstant piston speed or constant pressure
ComplianceASTM D3835, ISO 11443, GB/T 3680
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: All Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBWN-5-10KN
Max Load Capacity10 kN
Accuracy Class0.5
Force Measurement Range0.4–100% of full scale
Force Resolution1/200,000 of full scale (fixed, no range switching)
Effective Test Width400 mm (customizable)
Effective Tensile Travel800 mm (customizable)
Test Speed Range50–300 mm/min
Displacement & Strain Measurement Accuracy±0.5% of reading
Drive SystemServo Motor + Precision Ball Screw
Power Supply220 V / 380 V, 50 Hz
Power Consumption0.75 kW (typical)
Net Weight~300 kg
ComplianceGB/T 16491–2008, ASTM E4, ISO 7500-1, EN 10002-2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
ModelBEST-121
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Voltage RangeDC 10 V, 50 V, 100 V, 500 V, 1000 V
Resistance Measurement Range1×10⁴ Ω to 1×10¹⁸ Ω
Current Measurement Range2×10⁻⁴ A to 1×10⁻¹⁶ A
Operating Temperature0–40 °C
Relative Humidity≤70% RH
Power SupplyAC 220 V ±10%, 50 Hz
Continuous Operation Time8 hours
Power Consumption~10 W
Dimensions (W×D×H)285 mm × 245 mm × 120 mm
Weight~6 kg (main unit)
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: All Precision Instrument
ModelBWD-C
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ComplianceGB 1682, GB 5470–2008, HG 2-162–1965
Temperature RangeAmbient to –70 °C (ambient ≤25 °C)
Temperature Stability±0.3 °C
Cooling Rate~2.5 °C/min (0 to –30 °C), ~2.5 °C/min (–30 to –40 °C), ~2.0 °C/min (–40 to –70 °C)
Internal Chamber Dimensions280 × 170 × 120 mm (L×W×H)
External Dimensions900 × 500 × 800 mm (L×W×H)
Sample Capacity1 test fixture (4 rubber or 15 plastic specimens per cycle)
Timer Range0–99 min, 1 s resolution
Impact Head Radius1.6 ± 0.1 mm
Impact Gap6.4 ± 0.3 mm
Centerline Offset8 ± 0.3 mm
Cooling MediumIndustrial ethanol or non-freezing liquid
Circulation Motor8 W
Power Supply220–240 V AC, 50 Hz, 1.5 kW
Operating Ambient≤25 °C
Cooling SystemCompressor-based with proportional heating compensation
StirringContinuous circulation for thermal uniformity
SafetyIntegrated over-temperature and low-coolant-level alarm
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: All Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelC-50KV
Max Output Voltage50 kV AC/DC (RMS)
Input VoltageAC 220 V
Power Rating3 kVA
Voltage Ramp Rate0.1–5.0 kV/s (adjustable)
ComplianceGB/T 1981.2–2003, GB/T 7113.2–2005, GB/T 10580–2003, ISO 293, ISO 294-1, ISO 294-3, ISO 295, ISO 10724, IEC 60296, IEC 60455-2, IEC 60674-2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeElectronic Tensile Testing Machine
Maximum Test Load6 kN
Force Measurement Range2–100% of Full Scale
Force Accuracy±1% FS
Test Stroke600 mm
Displacement Resolution0.01 mm
Speed Range0.05–500 mm/min
Speed Accuracy±1%
Compliance StandardsGB/T 16491, GB/T 1040, ASTM D412, ASTM D3759, ISO 37, ISO 34-1, EN ISO 1798, DIN 53507-A
Power SupplyAC 220 V ±10%, 50 Hz, 0.5 kW
Dimensions (W×D×H)400 × 400 × 1300 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
ModelBG-800
Nominal Internal Volume50 L
Internal Dimensions (W×D×H)350 × 350 × 410 mm
External Dimensions (W×D×H)1110 × 870 × 1550 mm
Temperature Range−40 °C to +150 °C
Temperature Uniformity±2.0 °C
Temperature Stability±0.5 °C
Heating Rate (25 °C → 150 °C, unloaded)~35 min
Cooling Rate (25 °C → −40 °C, unloaded)~60 min
Power SupplyStandard industrial AC supply (specification compliant with GB/T 10592–2008 and IEC 60068-3-5)
ComplianceDesigned per ISO 16750-4, ASTM D4329, IEC 60068-2-1 (Cold), IEC 60068-2-2 (Dry Heat), and GB/T 2423.1–2022 / GB/T 2423.2–2022
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBDH-B
Output Voltage Range0–20 kV AC
Rated Power1.5 kVA
Test Current Options10 mA / 20 mA / 30 mA / 40 mA
Electrode Configuration110° included angle
Electrode MaterialsStainless steel plate electrode (25.4 mm × 12.7 mm × 0.15 mm), Tungsten carbide rod electrode (56 mm × 7 mm × 30 mm)
Arc Timing Accuracy<5 ms
Voltage Regulation Error≤1%
Test ModesIntermittent arc and continuous arc
Compliance StandardsGB/T 1411, IEC 61621, ASTM D495, IPC-TM-650 2.5.1, JIS C 2137, UL 746A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
ModelBWR-300 Series
Temperature RangeAmbient to 300 °C
Heating Rate Options120 ±5 °C/h or 50 ±3 °C/h
Temperature Resolution0.01 °C
Max. Temp. Accuracy±0.5 °C
Deformation MeasurementDigital Dial Gauge (Grating-Type)
Deformation Range–0.1 to 5.0 mm
Deformation Accuracy±0.01 mm
Sample Stations3 independent test positions per bath
Heating MediumMethyl Silicone Oil (flash point ≥300 °C, kinematic viscosity 200 cSt)
Heating Power2.5 kW
Cooling MethodNatural air cooling above 150 °C
Load CapacityVST: 10 N ±0.2 N or 50 N ±1 N
HDTconfigurable for ASTM D648 / ISO 75 stress levels (0.45, 1.80, or 8.00 MPa)
Span Options64 ±1 mm (flatwise) or 100 ±1 mm (edgewise)
Power SupplyAC 220 V ±10%, 50 Hz, 30 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelBES
PriceUSD 1,700 (approx.)
Resistance Range1 × 10⁴ Ω to 1 × 10¹⁸ Ω
Current Range2 × 10⁻⁴ A to 1 × 10⁻¹⁶ A
Test Voltages10 V, 50 V, 100 V, 250 V, 500 V, 1000 V (selectable)
Basic Accuracy±1%
Display32-bit LED LCD (simultaneous resistance and current readout)
Operating Environment0–40 °C, <80% RH
Power SupplyAC 220 V, 50 Hz, ~5 W
Dimensions285 mm × 245 mm × 120 mm
Weight~2.5 kg
Standard ElectrodesSolid disc electrode (Ø100 mm), concentric ring electrode (OD 75 mm / ID 55 ± 0.2 mm), cylindrical electrode (Ø50 mm), point-to-point probe set
Shielding Enclosure200 mm × 200 mm × 90 mm (internal height 50 mm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelJF-5
Oxygen Sensor Range0–100% O₂
Resolution±0.1%
Accuracy Class0.1
Flow Control Range0–20 L/min (0–1200 L/h)
Combustion Tube Internal Diameter Options≥75 mm or ≥85 mm
Gas Linear Velocity in Tube40 ± 2 mm/s
Input Pressure0.25–0.3 MPa
Operating Pressure (N₂/O₂)0.15–0.20 MPa
Power SupplyAC 220 V ±10%, 50 Hz
Max Power Consumption150 W
Ambient TempRoom Temp to 40 °C
Relative Humidity≤70%
Ignition Flame Length16 ± 4 mm (adjustable 5–60 mm)
Compliance StandardGB/T 2406.2–2009
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBHG-9102
Internal Dimensions (D×W×H)400 × 450 × 550 mm
Temperature Range−40 °C to +150 °C (unloaded)
Humidity Range20–98 %RH (no active thermal load)
Temperature Uniformity±2 °C (unloaded)
Temperature Fluctuation≤±0.5 °C (unloaded)
Humidity Fluctuation≤±3 %RH
Heating Rate≤40 min (20 °C to 100 °C)
Cooling Rate≤30 min (20 °C to −20 °C)
Control Accuracy±2 °C / ±3 %RH
Sensor TypePT100 armored resistance thermometers (temperature & humidity), dry-wet bulb principle for RH calculation
Refrigeration SystemSingle-stage, imported Tecumseh (France) compressor, R404A refrigerant (DuPont), Danfoss (Denmark) expansion valve, Parker (USA) filter-drier, Castel (Italy) solenoid valve
Humidification SystemBuilt-in stainless steel water tank with Taiwan-imported electronic level controller, visual glass water-level indicator
ControllerProgrammable high-resolution color touchscreen HMI, bilingual (English/Chinese), PID + BTHC balanced temperature-humidity control, 10 program groups × 16 segments (160 total), max segment time 99 h 59 min, up to 999 full cycles, USB data logging support
Safety ProtectionsOver-temperature alarm (chamber & compressor), over-current/overload protection, phase failure & ground fault detection, fan motor thermal protection, dry-run prevention for humidifier, fuse and SSR-based zero-crossing power control, leakage current protection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBDH-20KV
Voltage Range0–20 kV (continuously adjustable)
Arc Voltage Accuracy≤1%
Current Acquisition ResolutionMilliampere (mA)-level, real-time sampling
Communication InterfaceUSB 2.0 (up to 3 MB/s), RS-232, Bluetooth 5.0, optional regional Ethernet port
Control ModePC-based or embedded EPC terminal
Electrode MaterialsTungsten carbide, carbon steel, platinum
Cabinet MaterialAISI 304 stainless steel
Compliance StandardsGB/T 1411–2002 (equivalent to IEC 61621:1997), ASTM D495, IEC 149, UL 746A
Safety ProtectionsDual-stage overvoltage protection, short-circuit interruption, arc fault detection, interlocked safety door, automatic zero-voltage reset, post-test discharge circuit, independent grounding, TVS-based high-voltage surge suppression, software-based misoperation lockout
CalibrationSupplied with traceable calibration certificate from nationally accredited metrology institute (CNAS or equivalent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
Product OriginDomestic (China)
ModelGDA-A
PriceUSD 2,500 (approx.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
ManufacturerYes
ModelHMYS-200
Temperature RangeRT–200 °C
Chamber Volume (W×D×H)350×300×300 mm
External Dimensions600×420×450 mm
Temperature Uniformity±1% of full scale
Timer Range1–9999 min
Compression Ratios50%, 75%, 90%
Test Duration22 h
Specimen Size50×50×25 mm (5 pcs)
Glass Plate Thickness1.0–1.5 mm
Rated Voltage220 V AC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Instrument TypeCapillary Rheometer
ModelBML-400
Maximum Load Capacity10 kN / 25 kN (configurable)
Piston Speed Range0.0005–20 mm/sec
Dynamic Speed Ratio1:40,000
Maximum Test Temperature400 °C
Temperature Control Accuracy±0.2 °C (in barrel), ±0.5 °C (overall)
Barrel Diameter Options9.5 mm, 12 mm, 15 mm (custom lengths available)
Capillary Die Options(1) 5/0.5 mm (L=5 mm, D=0.5 mm), (2) 10/1 mm, (3) 20/1 mm, (4) 30/1 mm, (5) 20/2 mm
Pressure Sensor Range700–2000 bar (configurable)
Die MaterialTungsten carbide
Barrel & Piston MaterialNitrided stainless steel, corrosion- and wear-resistant
Safety FeaturesInterlocked front access door, dual overload protection, torque-limiting motor circuit
Power Supply1-phase, 220 V, 50/60 Hz, 8–12 A
Dimensions (W×D×H)64×64×165 cm
Weight250 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBDJC-50kV
Maximum Output Voltage50 kV AC/DC
Output CurrentAdjustable up to 100 mA (standard setting: 30 mA)
Voltage Accuracy≤ ±1%
Rising Rate Range10–3000 V/s (adjustable in 7 steps)
Power InputAC 220 V, 3 kVA
Electrode ConfigurationsTwo φ25 mm brass electrodes + One φ75 mm brass electrode
Test EnvironmentsAir or transformer oil immersion
ComplianceDesigned per IEC 60243-1, ASTM D149, GB/T 1408.1, and ISO 60243-1
Safety EnclosureTransparent acrylic shield
Dimensions (L×W×H)700 × 800 × 1500 mm
Weight~120 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNorth Guang Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic (China-made)
ModelBEST-121
PriceUSD 2,800 (approx.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNorth Guang Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelHMPL-2000
Max Test Force2000 N
Stroke Range0–100 mm
Compression Frequency20–120 cycles/min
Platen DiameterØ250 mm
Specimen Dimensions(380±20) mm × (380±20) mm × (50±2) mm
Load Accuracy±20 N (at 750 N setpoint)
DisplayLCD with Chinese UI
ComplianceGB/T 18941, ISO 3385, QC/T 56-93, JASO B408-84
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNorth Guangjingyi / All Precision Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelGDAT-C2
PriceUSD 4,950 (approx.)
Power SupplyAC 220 V ±10%, 50/60 Hz ±1%
Dimensions450 × 410 × 320 mm
Weight25 kg
Operating Temperature0–40 °C
Relative Humidity<75% RH
Capacitance Range5–200 pF
Relative Permittivity Range1.000–30.000
Dissipation Factor Range1×10⁻⁵–100
DC Resistivity Range2.5 MΩ·m–20 TΩ·m
Temperature Control Range0–125 °C
Temp. Accuracy±0.5 °C
AC Test Voltage200–2200 V (50 Hz, continuously adjustable)
DC Test Voltage0–500 V (continuously adjustable)
Heating MethodMedium-frequency induction with PID control
Electrode ConfigurationThree-electrode cell per GB/T 5654–2007, 2 mm inter-electrode gap
Internal Standard CapacitorSF₆-filled three-terminal capacitor
Data StorageOnboard non-volatile memory with real-time clock (RTC)
Display5.7″ TFT color touchscreen, full Chinese GUI
ComplianceGB/T 5654–2007, ASTM D924, IEC 60247, ISO 6296
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNorth Guang Precision Instrument
OriginBeijing, China
Manufacturer TypeManufacturer
ModelJF-3
Price RangeUSD 700 – 1,400 (FOB)
Oxygen Measurement Range0–100 vol%
Resolution±0.1% O₂
Overall AccuracyClass 0.2
Gas Flow Control0–10 L/min (60–600 L/h), adjustable via dual needle valves
Response Time<5 s
Combustion ColumnQuartz glass tube, ID ≥75 mm, height 300 mm, total height 450 mm
Gas Linear Velocity in Column40 ±2 mm/s
Pressure RegulationInlet pressure 0.2–0.3 MPa
working pressure for O₂/N₂0.05–0.15 MPa each
Ignition SourcePropane/butane torch with flame length 5–60 mm (standard ignition flame: 16 ±4 mm)
Sample HoldersDual-configurable—self-supporting vertical clamp & non-self-supporting frame-type fixture
Power SupplyAC 220 V ±10%, 50 Hz, max. 50 W
ComplianceGB/T 2406.1–2008, GB/T 2406.2–2009, ASTM D2863, ISO 4589-2, IEC 61144, NES 714
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0