Empowering Scientific Discovery

Beijing Beiguang Jingyi Instrument & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBG-400A1
Internal Dimensions (W×D×H)450 × 450 × 500 mm
Temperature Range10–300 °C
Temperature Uniformity±1 °C
Humidity RangeNot Applicable (Dry Heat / UV Only)
UV Wavelength340 nm (UVA-340 lamp standard)
Black Panel Temperature Range40–80 °C (adjustable per test protocol)
Irradiance Control0.63–1.25 W/m² @ 340 nm
Chamber Volume100 L
Heating Power2000 W
Power Supply220 V AC, 50/60 Hz
ComplianceGB/T 2951.12–2008, ASTM G154, ISO 4892-3, IEC 60068-2-5
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
ModelBG-800
Nominal Internal Volume50 L
Internal Dimensions (W×D×H)350 × 350 × 410 mm
External Dimensions (W×D×H)1110 × 870 × 1550 mm
Temperature Range−40 °C to +150 °C
Temperature Uniformity±2.0 °C
Temperature Stability±0.5 °C
Heating Rate (25 °C → 150 °C, unloaded)~35 min
Cooling Rate (25 °C → −40 °C, unloaded)~60 min
Power SupplyStandard industrial AC supply (specification compliant with GB/T 10592–2008 and IEC 60068-3-5)
ComplianceDesigned per ISO 16750-4, ASTM D4329, IEC 60068-2-1 (Cold), IEC 60068-2-2 (Dry Heat), and GB/T 2423.1–2022 / GB/T 2423.2–2022
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBHG-9102
Internal Dimensions (D×W×H)400 × 450 × 550 mm
Temperature Range−40 °C to +150 °C (unloaded)
Humidity Range20–98 %RH (no active thermal load)
Temperature Uniformity±2 °C (unloaded)
Temperature Fluctuation≤±0.5 °C (unloaded)
Humidity Fluctuation≤±3 %RH
Heating Rate≤40 min (20 °C to 100 °C)
Cooling Rate≤30 min (20 °C to −20 °C)
Control Accuracy±2 °C / ±3 %RH
Sensor TypePT100 armored resistance thermometers (temperature & humidity), dry-wet bulb principle for RH calculation
Refrigeration SystemSingle-stage, imported Tecumseh (France) compressor, R404A refrigerant (DuPont), Danfoss (Denmark) expansion valve, Parker (USA) filter-drier, Castel (Italy) solenoid valve
Humidification SystemBuilt-in stainless steel water tank with Taiwan-imported electronic level controller, visual glass water-level indicator
ControllerProgrammable high-resolution color touchscreen HMI, bilingual (English/Chinese), PID + BTHC balanced temperature-humidity control, 10 program groups × 16 segments (160 total), max segment time 99 h 59 min, up to 999 full cycles, USB data logging support
Safety ProtectionsOver-temperature alarm (chamber & compressor), over-current/overload protection, phase failure & ground fault detection, fan motor thermal protection, dry-run prevention for humidifier, fuse and SSR-based zero-crossing power control, leakage current protection
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0