| Model | BU-800A |
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Producer |
| Power Supply | 220 V ±5%, 50 Hz, 2 kW |
| UV Lamp Configuration | 16 × 20 W low-pressure mercury lamps (253.7 nm peak output) |
| Conveyor Speed | 0–5 m/min (infinitely variable, digital display) |
| Tunnel Dimensions | 2000 mm (L) × 500 mm (W) × 200–300 mm (H, adjustable inlet/outlet height) |
| UV Exposure Zone | 1000 mm |
| Construction Material | 304 stainless steel (outer shell: 1.2 mm |
| inner reflective chamber | 1.0 mm mirror-finish #2B) |
| Conveyor Belt | Black PTFE-coated mesh belt |
| Safety Features | Light-shielded entry/exit zones with adjustable baffles, overvoltage/overcurrent protection, real-time lamp hour counter, fault alarm indication |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BWD-D |
| Temperature Control Range | Ambient to –70 °C (ambient ≤25 °C) |
| Temperature Stability | ±0.3 °C |
| Cooling Rate | ~2.5 °C/min (0 °C to –30 °C) |
| Internal Chamber Dimensions | 280 × 170 × 120 mm (L×W×H) |
| External Dimensions | 900 × 500 × 800 mm (L×W×H) |
| Sample Capacity | 1 test fixture (4 rubber specimens or 15 plastic specimens per test cycle) |
| Timer Range | 0–99 min, 1-s resolution |
| Cooling Medium | Ethanol or other non-freezing liquid |
| Stirring Motor Power | 8 W |
| Power Supply | 220–240 V AC, 50 Hz, 1.5 kW |
| Operating Ambient Limit | ≤25 °C |
| Impact Head Radius | 1.6 ± 0.1 mm |
| Impact Gap (head to specimen holder) | 6.4 ± 0.3 mm |
| Horizontal Offset (impact centerline to holder centerline) | 8 ± 0.3 mm |
| Key | Brand: All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BWN-5-10KN |
| Max Load Capacity | 10 kN |
| Accuracy Class | 0.5 |
| Force Measurement Range | 0.4–100% of full scale |
| Force Resolution | 1/200,000 of full scale (fixed, no range switching) |
| Effective Test Width | 400 mm (customizable) |
| Effective Tensile Travel | 800 mm (customizable) |
| Test Speed Range | 50–300 mm/min |
| Displacement & Strain Measurement Accuracy | ±0.5% of reading |
| Drive System | Servo Motor + Precision Ball Screw |
| Power Supply | 220 V / 380 V, 50 Hz |
| Power Consumption | 0.75 kW (typical) |
| Net Weight | ~300 kg |
| Compliance | GB/T 16491–2008, ASTM E4, ISO 7500-1, EN 10002-2 |
| Brand | All Precision Instrument |
|---|---|
| Model | BEST-121 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Voltage Range | DC 10 V, 50 V, 100 V, 500 V, 1000 V |
| Resistance Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Measurement Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤70% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Continuous Operation Time | 8 hours |
| Power Consumption | ~10 W |
| Dimensions (W×D×H) | 285 mm × 245 mm × 120 mm |
| Weight | ~6 kg (main unit) |
| Key | Brand: All Precision Instrument |
|---|---|
| Model | BWD-C |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance | GB 1682, GB 5470–2008, HG 2-162–1965 |
| Temperature Range | Ambient to –70 °C (ambient ≤25 °C) |
| Temperature Stability | ±0.3 °C |
| Cooling Rate | ~2.5 °C/min (0 to –30 °C), ~2.5 °C/min (–30 to –40 °C), ~2.0 °C/min (–40 to –70 °C) |
| Internal Chamber Dimensions | 280 × 170 × 120 mm (L×W×H) |
| External Dimensions | 900 × 500 × 800 mm (L×W×H) |
| Sample Capacity | 1 test fixture (4 rubber or 15 plastic specimens per cycle) |
| Timer Range | 0–99 min, 1 s resolution |
| Impact Head Radius | 1.6 ± 0.1 mm |
| Impact Gap | 6.4 ± 0.3 mm |
| Centerline Offset | 8 ± 0.3 mm |
| Cooling Medium | Industrial ethanol or non-freezing liquid |
| Circulation Motor | 8 W |
| Power Supply | 220–240 V AC, 50 Hz, 1.5 kW |
| Operating Ambient | ≤25 °C |
| Cooling System | Compressor-based with proportional heating compensation |
| Stirring | Continuous circulation for thermal uniformity |
| Safety | Integrated over-temperature and low-coolant-level alarm |
| Key | Brand: All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | C-50KV |
| Max Output Voltage | 50 kV AC/DC (RMS) |
| Input Voltage | AC 220 V |
| Power Rating | 3 kVA |
| Voltage Ramp Rate | 0.1–5.0 kV/s (adjustable) |
| Compliance | GB/T 1981.2–2003, GB/T 7113.2–2005, GB/T 10580–2003, ISO 293, ISO 294-1, ISO 294-3, ISO 295, ISO 10724, IEC 60296, IEC 60455-2, IEC 60674-2 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Electronic Tensile Testing Machine |
| Maximum Test Load | 6 kN |
| Force Measurement Range | 2–100% of Full Scale |
| Force Accuracy | ±1% FS |
| Test Stroke | 600 mm |
| Displacement Resolution | 0.01 mm |
| Speed Range | 0.05–500 mm/min |
| Speed Accuracy | ±1% |
| Compliance Standards | GB/T 16491, GB/T 1040, ASTM D412, ASTM D3759, ISO 37, ISO 34-1, EN ISO 1798, DIN 53507-A |
| Power Supply | AC 220 V ±10%, 50 Hz, 0.5 kW |
| Dimensions (W×D×H) | 400 × 400 × 1300 mm |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BDH-B |
| Output Voltage Range | 0–20 kV AC |
| Rated Power | 1.5 kVA |
| Test Current Options | 10 mA / 20 mA / 30 mA / 40 mA |
| Electrode Configuration | 110° included angle |
| Electrode Materials | Stainless steel plate electrode (25.4 mm × 12.7 mm × 0.15 mm), Tungsten carbide rod electrode (56 mm × 7 mm × 30 mm) |
| Arc Timing Accuracy | <5 ms |
| Voltage Regulation Error | ≤1% |
| Test Modes | Intermittent arc and continuous arc |
| Compliance Standards | GB/T 1411, IEC 61621, ASTM D495, IPC-TM-650 2.5.1, JIS C 2137, UL 746A |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | BWR-300 Series |
| Temperature Range | Ambient to 300 °C |
| Heating Rate Options | 120 ±5 °C/h or 50 ±3 °C/h |
| Temperature Resolution | 0.01 °C |
| Max. Temp. Accuracy | ±0.5 °C |
| Deformation Measurement | Digital Dial Gauge (Grating-Type) |
| Deformation Range | –0.1 to 5.0 mm |
| Deformation Accuracy | ±0.01 mm |
| Sample Stations | 3 independent test positions per bath |
| Heating Medium | Methyl Silicone Oil (flash point ≥300 °C, kinematic viscosity 200 cSt) |
| Heating Power | 2.5 kW |
| Cooling Method | Natural air cooling above 150 °C |
| Load Capacity | VST: 10 N ±0.2 N or 50 N ±1 N |
| HDT | configurable for ASTM D648 / ISO 75 stress levels (0.45, 1.80, or 8.00 MPa) |
| Span Options | 64 ±1 mm (flatwise) or 100 ±1 mm (edgewise) |
| Power Supply | AC 220 V ±10%, 50 Hz, 30 A |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BDH-20KV |
| Voltage Range | 0–20 kV (continuously adjustable) |
| Arc Voltage Accuracy | ≤1% |
| Current Acquisition Resolution | Milliampere (mA)-level, real-time sampling |
| Communication Interface | USB 2.0 (up to 3 MB/s), RS-232, Bluetooth 5.0, optional regional Ethernet port |
| Control Mode | PC-based or embedded EPC terminal |
| Electrode Materials | Tungsten carbide, carbon steel, platinum |
| Cabinet Material | AISI 304 stainless steel |
| Compliance Standards | GB/T 1411–2002 (equivalent to IEC 61621:1997), ASTM D495, IEC 149, UL 746A |
| Safety Protections | Dual-stage overvoltage protection, short-circuit interruption, arc fault detection, interlocked safety door, automatic zero-voltage reset, post-test discharge circuit, independent grounding, TVS-based high-voltage surge suppression, software-based misoperation lockout |
| Calibration | Supplied with traceable calibration certificate from nationally accredited metrology institute (CNAS or equivalent) |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Model | HMYS-200 |
| Temperature Range | RT–200 °C |
| Chamber Volume (W×D×H) | 350×300×300 mm |
| External Dimensions | 600×420×450 mm |
| Temperature Uniformity | ±1% of full scale |
| Timer Range | 1–9999 min |
| Compression Ratios | 50%, 75%, 90% |
| Test Duration | 22 h |
| Specimen Size | 50×50×25 mm (5 pcs) |
| Glass Plate Thickness | 1.0–1.5 mm |
| Rated Voltage | 220 V AC |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BDJC-50kV |
| Maximum Output Voltage | 50 kV AC/DC |
| Output Current | Adjustable up to 100 mA (standard setting: 30 mA) |
| Voltage Accuracy | ≤ ±1% |
| Rising Rate Range | 10–3000 V/s (adjustable in 7 steps) |
| Power Input | AC 220 V, 3 kVA |
| Electrode Configurations | Two φ25 mm brass electrodes + One φ75 mm brass electrode |
| Test Environments | Air or transformer oil immersion |
| Compliance | Designed per IEC 60243-1, ASTM D149, GB/T 1408.1, and ISO 60243-1 |
| Safety Enclosure | Transparent acrylic shield |
| Dimensions (L×W×H) | 700 × 800 × 1500 mm |
| Weight | ~120 kg |
| Brand | North Guang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HMPL-2000 |
| Max Test Force | 2000 N |
| Stroke Range | 0–100 mm |
| Compression Frequency | 20–120 cycles/min |
| Platen Diameter | Ø250 mm |
| Specimen Dimensions | (380±20) mm × (380±20) mm × (50±2) mm |
| Load Accuracy | ±20 N (at 750 N setpoint) |
| Display | LCD with Chinese UI |
| Compliance | GB/T 18941, ISO 3385, QC/T 56-93, JASO B408-84 |
| Brand | Beiguang Jingyi / All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Pendulum Impact Tester |
| Impact Energy Options | 7.5 J, 15 J, 25 J, 50 J (custom higher energy available) |
| Impact Velocity | 3.8 m/s |
| Pendulum Center Distance (Support Span) | 395 mm |
| Pendulum Pre-lift Angle | 150° |
| Blade Radius | 0.8 ± 0.2 mm |
| Blade Angle | 75° |
| Blade Front Angle | 5° |
| Blade Back Angle | 10° |
| Test Specimen Support Span Options | 60 mm, 70 mm, 62 mm, 95 mm (configurable per standard) |
| Display | LCD Digital Readout with Photoelectric Encoder (2500-line resolution, ±0.018° angular accuracy) |
| Energy Calculation Method | Potential Energy Loss (E = Pd·(cosβ − cosα)) with Air Friction & Bearing Loss Correction |
| Power Supply | 220 V AC ±10%, 50 Hz, 0.2 A |
| Operating Temperature | 15–35 °C |
| Dimensions (W×D×H) | 930 × 520 × 950 mm |
| Net Weight | 80 kg |
| Compliance | GB/T 1043-1993, ISO 179-1:2010, GB/T 2611-2007, JB/T 8762-1998 |