Empowering Scientific Discovery

Beijing Beiguang Jingyi Instrument & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
ModelBU-800A
OriginBeijing, China
Manufacturer TypeOEM/ODM Producer
Power Supply220 V ±5%, 50 Hz, 2 kW
UV Lamp Configuration16 × 20 W low-pressure mercury lamps (253.7 nm peak output)
Conveyor Speed0–5 m/min (infinitely variable, digital display)
Tunnel Dimensions2000 mm (L) × 500 mm (W) × 200–300 mm (H, adjustable inlet/outlet height)
UV Exposure Zone1000 mm
Construction Material304 stainless steel (outer shell: 1.2 mm
inner reflective chamber1.0 mm mirror-finish #2B)
Conveyor BeltBlack PTFE-coated mesh belt
Safety FeaturesLight-shielded entry/exit zones with adjustable baffles, overvoltage/overcurrent protection, real-time lamp hour counter, fault alarm indication
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelBWD-D
Temperature Control RangeAmbient to –70 °C (ambient ≤25 °C)
Temperature Stability±0.3 °C
Cooling Rate~2.5 °C/min (0 °C to –30 °C)
Internal Chamber Dimensions280 × 170 × 120 mm (L×W×H)
External Dimensions900 × 500 × 800 mm (L×W×H)
Sample Capacity1 test fixture (4 rubber specimens or 15 plastic specimens per test cycle)
Timer Range0–99 min, 1-s resolution
Cooling MediumEthanol or other non-freezing liquid
Stirring Motor Power8 W
Power Supply220–240 V AC, 50 Hz, 1.5 kW
Operating Ambient Limit≤25 °C
Impact Head Radius1.6 ± 0.1 mm
Impact Gap (head to specimen holder)6.4 ± 0.3 mm
Horizontal Offset (impact centerline to holder centerline)8 ± 0.3 mm
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: All Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBWN-5-10KN
Max Load Capacity10 kN
Accuracy Class0.5
Force Measurement Range0.4–100% of full scale
Force Resolution1/200,000 of full scale (fixed, no range switching)
Effective Test Width400 mm (customizable)
Effective Tensile Travel800 mm (customizable)
Test Speed Range50–300 mm/min
Displacement & Strain Measurement Accuracy±0.5% of reading
Drive SystemServo Motor + Precision Ball Screw
Power Supply220 V / 380 V, 50 Hz
Power Consumption0.75 kW (typical)
Net Weight~300 kg
ComplianceGB/T 16491–2008, ASTM E4, ISO 7500-1, EN 10002-2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
ModelBEST-121
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Voltage RangeDC 10 V, 50 V, 100 V, 500 V, 1000 V
Resistance Measurement Range1×10⁴ Ω to 1×10¹⁸ Ω
Current Measurement Range2×10⁻⁴ A to 1×10⁻¹⁶ A
Operating Temperature0–40 °C
Relative Humidity≤70% RH
Power SupplyAC 220 V ±10%, 50 Hz
Continuous Operation Time8 hours
Power Consumption~10 W
Dimensions (W×D×H)285 mm × 245 mm × 120 mm
Weight~6 kg (main unit)
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: All Precision Instrument
ModelBWD-C
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ComplianceGB 1682, GB 5470–2008, HG 2-162–1965
Temperature RangeAmbient to –70 °C (ambient ≤25 °C)
Temperature Stability±0.3 °C
Cooling Rate~2.5 °C/min (0 to –30 °C), ~2.5 °C/min (–30 to –40 °C), ~2.0 °C/min (–40 to –70 °C)
Internal Chamber Dimensions280 × 170 × 120 mm (L×W×H)
External Dimensions900 × 500 × 800 mm (L×W×H)
Sample Capacity1 test fixture (4 rubber or 15 plastic specimens per cycle)
Timer Range0–99 min, 1 s resolution
Impact Head Radius1.6 ± 0.1 mm
Impact Gap6.4 ± 0.3 mm
Centerline Offset8 ± 0.3 mm
Cooling MediumIndustrial ethanol or non-freezing liquid
Circulation Motor8 W
Power Supply220–240 V AC, 50 Hz, 1.5 kW
Operating Ambient≤25 °C
Cooling SystemCompressor-based with proportional heating compensation
StirringContinuous circulation for thermal uniformity
SafetyIntegrated over-temperature and low-coolant-level alarm
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: All Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelC-50KV
Max Output Voltage50 kV AC/DC (RMS)
Input VoltageAC 220 V
Power Rating3 kVA
Voltage Ramp Rate0.1–5.0 kV/s (adjustable)
ComplianceGB/T 1981.2–2003, GB/T 7113.2–2005, GB/T 10580–2003, ISO 293, ISO 294-1, ISO 294-3, ISO 295, ISO 10724, IEC 60296, IEC 60455-2, IEC 60674-2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeElectronic Tensile Testing Machine
Maximum Test Load6 kN
Force Measurement Range2–100% of Full Scale
Force Accuracy±1% FS
Test Stroke600 mm
Displacement Resolution0.01 mm
Speed Range0.05–500 mm/min
Speed Accuracy±1%
Compliance StandardsGB/T 16491, GB/T 1040, ASTM D412, ASTM D3759, ISO 37, ISO 34-1, EN ISO 1798, DIN 53507-A
Power SupplyAC 220 V ±10%, 50 Hz, 0.5 kW
Dimensions (W×D×H)400 × 400 × 1300 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBDH-B
Output Voltage Range0–20 kV AC
Rated Power1.5 kVA
Test Current Options10 mA / 20 mA / 30 mA / 40 mA
Electrode Configuration110° included angle
Electrode MaterialsStainless steel plate electrode (25.4 mm × 12.7 mm × 0.15 mm), Tungsten carbide rod electrode (56 mm × 7 mm × 30 mm)
Arc Timing Accuracy<5 ms
Voltage Regulation Error≤1%
Test ModesIntermittent arc and continuous arc
Compliance StandardsGB/T 1411, IEC 61621, ASTM D495, IPC-TM-650 2.5.1, JIS C 2137, UL 746A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
ModelBWR-300 Series
Temperature RangeAmbient to 300 °C
Heating Rate Options120 ±5 °C/h or 50 ±3 °C/h
Temperature Resolution0.01 °C
Max. Temp. Accuracy±0.5 °C
Deformation MeasurementDigital Dial Gauge (Grating-Type)
Deformation Range–0.1 to 5.0 mm
Deformation Accuracy±0.01 mm
Sample Stations3 independent test positions per bath
Heating MediumMethyl Silicone Oil (flash point ≥300 °C, kinematic viscosity 200 cSt)
Heating Power2.5 kW
Cooling MethodNatural air cooling above 150 °C
Load CapacityVST: 10 N ±0.2 N or 50 N ±1 N
HDTconfigurable for ASTM D648 / ISO 75 stress levels (0.45, 1.80, or 8.00 MPa)
Span Options64 ±1 mm (flatwise) or 100 ±1 mm (edgewise)
Power SupplyAC 220 V ±10%, 50 Hz, 30 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBDH-20KV
Voltage Range0–20 kV (continuously adjustable)
Arc Voltage Accuracy≤1%
Current Acquisition ResolutionMilliampere (mA)-level, real-time sampling
Communication InterfaceUSB 2.0 (up to 3 MB/s), RS-232, Bluetooth 5.0, optional regional Ethernet port
Control ModePC-based or embedded EPC terminal
Electrode MaterialsTungsten carbide, carbon steel, platinum
Cabinet MaterialAISI 304 stainless steel
Compliance StandardsGB/T 1411–2002 (equivalent to IEC 61621:1997), ASTM D495, IEC 149, UL 746A
Safety ProtectionsDual-stage overvoltage protection, short-circuit interruption, arc fault detection, interlocked safety door, automatic zero-voltage reset, post-test discharge circuit, independent grounding, TVS-based high-voltage surge suppression, software-based misoperation lockout
CalibrationSupplied with traceable calibration certificate from nationally accredited metrology institute (CNAS or equivalent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
ManufacturerYes
ModelHMYS-200
Temperature RangeRT–200 °C
Chamber Volume (W×D×H)350×300×300 mm
External Dimensions600×420×450 mm
Temperature Uniformity±1% of full scale
Timer Range1–9999 min
Compression Ratios50%, 75%, 90%
Test Duration22 h
Specimen Size50×50×25 mm (5 pcs)
Glass Plate Thickness1.0–1.5 mm
Rated Voltage220 V AC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAll Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelBDJC-50kV
Maximum Output Voltage50 kV AC/DC
Output CurrentAdjustable up to 100 mA (standard setting: 30 mA)
Voltage Accuracy≤ ±1%
Rising Rate Range10–3000 V/s (adjustable in 7 steps)
Power InputAC 220 V, 3 kVA
Electrode ConfigurationsTwo φ25 mm brass electrodes + One φ75 mm brass electrode
Test EnvironmentsAir or transformer oil immersion
ComplianceDesigned per IEC 60243-1, ASTM D149, GB/T 1408.1, and ISO 60243-1
Safety EnclosureTransparent acrylic shield
Dimensions (L×W×H)700 × 800 × 1500 mm
Weight~120 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNorth Guang Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelHMPL-2000
Max Test Force2000 N
Stroke Range0–100 mm
Compression Frequency20–120 cycles/min
Platen DiameterØ250 mm
Specimen Dimensions(380±20) mm × (380±20) mm × (50±2) mm
Load Accuracy±20 N (at 750 N setpoint)
DisplayLCD with Chinese UI
ComplianceGB/T 18941, ISO 3385, QC/T 56-93, JASO B408-84
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeiguang Jingyi / All Precision Instrument
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypePendulum Impact Tester
Impact Energy Options7.5 J, 15 J, 25 J, 50 J (custom higher energy available)
Impact Velocity3.8 m/s
Pendulum Center Distance (Support Span)395 mm
Pendulum Pre-lift Angle150°
Blade Radius0.8 ± 0.2 mm
Blade Angle75°
Blade Front Angle
Blade Back Angle10°
Test Specimen Support Span Options60 mm, 70 mm, 62 mm, 95 mm (configurable per standard)
DisplayLCD Digital Readout with Photoelectric Encoder (2500-line resolution, ±0.018° angular accuracy)
Energy Calculation MethodPotential Energy Loss (E = Pd·(cosβ − cosα)) with Air Friction & Bearing Loss Correction
Power Supply220 V AC ±10%, 50 Hz, 0.2 A
Operating Temperature15–35 °C
Dimensions (W×D×H)930 × 520 × 950 mm
Net Weight80 kg
ComplianceGB/T 1043-1993, ISO 179-1:2010, GB/T 2611-2007, JB/T 8762-1998
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0