- All
- Favorite
- Popular
- Most rated
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.5 mg/L |
| Accuracy | ±5% |
| Resolution | 1 µg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Power Consumption | 95 W |
| Dimensions | 340 × 390 × 145 mm |
| Weight | 15 kg |
| Response Time | ≤6 min |
| Sample Temperature Range | 1–95 °C |
| Ambient Temperature | 10–40 °C |
| Relative Humidity | ≤85% RH |
| Linearity Error | ±5% |
| Control Interface | Color Touchscreen with Embedded System |
| Connectivity | Bluetooth Wireless Control |
| Compliance | Chinese Pharmacopoeia 2015 Edition, Appendix VIII R |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Membrane Conductivity Differential Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.0 mg/L (customizable up to 1000 mg/L via sensor configuration) |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Sample Temperature Range | 1–95 °C |
| Analysis Time | <4 minutes per sample |
| Display | 640×480 color touchscreen |
| Data Storage | 6-month history (≥10,000 records) |
| Interface | RS232 |
| Compliance | Chinese Pharmacopoeia 2010 Edition, Appendix VIII R |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | UV/Persulfate Oxidation + NDIR (Non-Dispersive Infrared) Detection |
| Measurement Range | 0.001–1.0 mg/L (customizable up to 1000 mg/L via sensor configuration) |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Response Time | <4 minutes |
| Sample Temperature Range | 1–95 °C |
| Display | 640×480 color TFT touchscreen |
| Data Storage | 6-month history retention |
| Compliance | Chinese Pharmacopoeia 2010 Edition, Appendix VIII R |
| Interface | RS232 |
| Power Supply | 220 V AC |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Model | BC-40A |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.000 mg/L |
| Accuracy | ±5% |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Analysis Time | 4 min |
| Response Time | ≤15 min |
| Sample Temperature Range | 1–95 °C |
| Ambient Temperature Range | 10–40 °C (max. ±5 °C/day drift) |
| Internal Flow Rate | 0.5 mL/min |
| Relative Humidity | ≤85% |
| Zero Drift | ±5% FS/24 h |
| Span Drift | ±5% FS/24 h |
| UV Lamp | Dual-wavelength (185 nm & 254 nm) |
| Pump Tubing | Imported high-stability peristaltic tubing |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Detection after UV/Persulfate Oxidation |
| Oxidation Method | High-Temperature Catalytic Combustion (supplemented by UV/persulfate for low-level precision) |
| Measurement Range | 0.01–1000 µg/L (0.01–1.000 mg/L) |
| Accuracy | ±4% of reading within calibrated range |
| Resolution | 0.001 mg/L (1 µg/L) |
| Detection Limit | 0.001 mg/L (1 µg/L) |
| Repeatability | ≤3% RSD |
| Sample Temperature Range | 1–95 °C |
| Analysis Time | ≤6 minutes per sample |
| Data Storage | Internal memory supporting ≥6 months of timestamped records |
| Compliance | USP <643>, EP 2.2.44, ChP 2020 Edition (General Chapter 0682), FDA CGMP Annex 1 (Water Systems), ISO 8573-1 (for pharmaceutical compressed air-associated water), GLP/GMP-ready audit trail capability |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0–50,000 ppm (as C) |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Sample Temperature Range | 1–90 °C |
| Analysis Time | <6 minutes |
| Power Supply | 220 V AC |
| Display | Color Touchscreen |
| Compliance | Chinese Pharmacopoeia 2010 Edition |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Model | BC-40 |
| Detection Principle | Membrane Conductivity Difference Method |
| Oxidation Method | UV Photolysis (185 nm) |
| Measurement Range | 0.001–1.5 mg/L |
| Accuracy | ±5% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Power Consumption | 95 W |
| Dimensions | 340 × 390 × 145 mm |
| Weight | 15 kg |
| Response Time | ≤6 min |
| Sample Temperature Range | 1–95 °C |
| Operating Environment | 10–40 °C, ≤85% RH |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory-Scale Offline TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.000 mg/L |
| Accuracy | ±5% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% RSD |
| Analysis Time | 4 min |
| Response Time | ≤15 min |
| Sample Temperature Range | 1–95 °C |
| Ambient Operating Temperature | 10–40 °C (±5 °C/day max) |
| Internal Flow Rate | 0.5 mL/min |
| Relative Humidity | ≤85% |
| Zero Drift | ±5% FS |
| Span Drift | ±5% FS |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz, 100 W |
| Dimensions | 44 × 18 × 26 cm |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0–50,000 µg/L (ppb) as C |
| Accuracy | ±4% of reading |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.05 mg/L |
| Repeatability | ≤3% RSD |
| Conductivity Range Limit | <10.0 µS/cm |
| Sample Temperature Range | 1–90 °C |
| Power Supply | 220 V AC, 50/60 Hz |
| Operating Ambient Temperature | 5–40 °C |
| Display | Color Touchscreen |
| Analysis Time | ≤6 minutes per sample |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BC-40A Standard |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.000 mg/L |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Analysis Time | ≤6 minutes |
| Sample Temperature Range | 1–90 °C |
| Power Supply | 220 V AC |
| Display | Color Touchscreen |
Show next