OriginBeijing
Manufacturer TypeDistributor
Origin CategoryDomestic (China)
ModelXJL-300C
QuotationUpon Request
Ambient Temperature Range10–35 °C
Hammer Mass Range0.250–15.00 kg (increments of 0.100 kg and 0.250 kg
certified masses1.000 kg and 2.000 kg with ±0.1% accuracy)
Hammer Nose RadiiR5 mm, R10 mm, R12.5 mm, R30 mm, R50 mm
Impact Height Range50–2000 mm (height indication error ≤ ±2 mm)
Specimen Diameter CapacityΦ10–Φ630 mm
Power Supply220 V AC ±10%, 50 Hz, 500 W (single-phase, three-wire)
Lifting Speed12 m/min
Overall Dimensions850 mm × 950 mm × 3350 mm
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelXCB-300I
PricingAvailable Upon Request
Max Operating Temperature300 °C
Temperature Control Range50–300 °C
Temperature Stability±2 °C
Temperature Uniformity±2.5% (at setpoint)
Internal Chamber Dimensions450 mm × 550 mm × 550 mm (W × D × H)
Fan Motor Power40 W
Heating Power2.8 kW
Input Voltage220 VAC ±10% (−15% to +10% tolerance)
External Dimensions675 mm × 920 mm × 950 mm (W × D × H)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
ModelXCB-300II
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
KeyOrigin: Beijing, China
Manufacturer TypeDistributor
ModelDRY-3.5
QuotationUpon Request
Total Force3.50 ± 0.02 N
Plunger Tip Diameter3.15 ± 0.03 mm
Test Station Capacity6-position fixture
Specimen GeometryØ12 mm circular disc or 12 mm × 12 mm square
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHARKE
ModelHK-Q3
Measurement PrincipleVacuum Method (ASTM D1434, ISO 2556, ISO 15105-1)
Test GasesO₂, N₂, CO₂, Air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃
Permeation Range0.05–160,000 cm³/(m²·24h·0.1 MPa)
Resolution0.001 cm³/(m²·24h·0.1 MPa)
Vacuum Resolution0.1 Pa
Temperature Control Range5–95 °C (external chiller/heater required)
Temp. Stability±0.1 °C
Sample Thickness≤5 mm (customizable)
Sample Area48 cm²
Sample Dimensions≥150 mm × 94 mm or circular
Test Pressure Range−0.1 to +0.1 MPa
Supply Gas Pressure0.3–1.0 MPa
Gas Inlet PortØ8 mm
Dimensions (L×D×H)330 × 600 × 330 mm
Weight28 kg
PowerAC 220 V, 50 Hz
ComplianceASTM D1434, ISO 2556, ISO 15105-1, GB/T 1038, YY/T 0698.5