| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | GTR-3 |
| Pricing | Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | HK-W2 |
| Pricing | Upon Request |
| Brand | HARKE |
|---|---|
| Model | HK-701R |
| Principle | Vacuum Method (ASTM D3985, ISO 15105-2) |
| Test Range | 0.007–190,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Sample Count | 1–3 independent stations |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH, 2–98.5% RH, 100% RH (optional humidity generator) |
| Humidity Accuracy | ±1% RH |
| Max Sample Thickness | ≤5 mm (customizable) |
| Sample Size | ≥150 mm × 94 mm or circular |
| Effective Test Area | 48 cm² |
| Test Gases | O₂, N₂, CO₂, air, He (user-supplied gas source) |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Dimensions (L×W×H) | 730 × 510 × 350 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 63 kg |
| Brand | HARKE |
|---|---|
| Model | HK-T-391 |
| Origin | Beijing, China |
| Manufacturer | Yes |
| Type | Domestic |
| Measurement Range | 1×10⁻⁵ – 1×10⁻¹⁴ cm³(STP)·mm/cm²·s·cmHg |
| Test Method | TCD Detection + Chromatographic Calibration Curve |
| Max Sample Thickness | ≤1 mm |
| Detection Sensitivity | ≥3000 mV·mL/mg (for benzene & H₂) |
| Test Area | 50 cm² |
| Sample Capacity | 1 standard specimen (multi-specimen option available) |
| Test Chamber Temp. Range | 5–95 °C |
| Temp. Control Accuracy | ±0.1 °C |
| Carrier Gas Line Temp. Range | RT+5–100 °C |
| Carrier Gas | He or H₂ (selectable) |
| Carrier Pressure | 0.05–0.5 MPa |
| Test Gas Pressure Differential | −0.1 to +0.1 MPa |
| Vacuum Level in Test Chamber | <20 Pa |
| Applicable Gases | Air, O₂, N₂, CO, CO₂, CH₄, H₂, He, NH₃, C₃H₈, C₄H₁₀ (custom gases available |
| Dimensions | 330 × 380 × 410 mm (L×W×H) |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 46 kg |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HK-100T |
| Pricing | Available Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | HK-701M |
| Measurement Principle | Vacuum-Pressure Differential Method |
| Test Gases | O₂, CO₂, N₂, Air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ |
| Test Range | 0.01–150,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Sample Capacity | 1–3 independent chambers |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range (optional) | 0%RH, 2–98.5%RH, 100%RH |
| Humidity Accuracy | ±1%RH |
| Max Sample Thickness | ≤5 mm |
| Sample Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Dimensions (L×W×H) | 730 × 510 × 350 mm |
| Weight | 63 kg |
| Compliance | GB/T 1038–2000, ISO 15105-1, ISO 2556, ASTM D1434, JIS K 7126-1, YBB 00082003 |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Domestic Product | Yes |
| Model | HK-V3 |
| Pricing | Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HK-CV3 |
| Pricing | Available Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HK-R3 |
| Pricing | Upon Request |
| Brand | HARKE |
|---|---|
| Model | HK-X3 |
| Measurement Principle | Vacuum Method (ASTM D1434, ISO 2556, ISO 15105-1) |
| Test Gases | O₂, N₂, CO₂, Air, He, H₂, CH₄, NH₃, C₃H₈, C₄H₁₀ (hazardous gases require pre-order specification) |
| Permeation Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C (external chiller/heater required) |
| Temp. Stability | ±0.1 °C |
| Sample Thickness | ≤5 mm (customizable) |
| Sample Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Chamber | Single independent cavity |
| Pressure Range | −0.1 to +0.1 MPa |
| Supply Pressure | 0.3–1.0 MPa |
| Inlet Port | Ø8 mm |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Weight | 28 kg |
| Power | AC 220 V, 50 Hz |
| Brand | HARKE |
|---|---|
| Model | HK-G3 |
| Measurement Range | 10–10,000 s/100 mL·in² at 1.22 kPa |
| Pressure Control Range | 0–20 kPa (customizable) |
| Sample Thickness Limit | ≤5 mm |
| Test Area | 0.025 in² |
| Vacuum Resolution | 0.1 Pa |
| Sample Count per Run | 1 |
| Gas Compatibility | O₂, N₂, CO₂, air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ (hazardous gases require pre-consultation) |
| Interface | Ø8 mm tubing |
| Dimensions (L×W×H) | 730 × 510 × 350 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 68 kg |
| Control System | Embedded 32-bit ARM processor with TFT color touchscreen |
| Automation Level | Fully automatic sample clamping, pressure regulation, vacuum evacuation, and data acquisition |
| Output Parameters | Gas Transmission Rate (GTR), Permeability Coefficient (P), Diffusion Coefficient (D), Solubility Coefficient (S) |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HK-GR3 |
| Quotation | Available upon request |
| Measurement Principle | Vacuum-based differential pressure method |
| Test Range | 0.05–160,000 cm³/m²·24h·0.1MPa (standard configuration) |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Specimen Count | 1 |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5°C–95°C (external chiller/heater required) |
| Temperature Accuracy | ±0.1°C |
| Max Specimen Thickness | ≤5 mm (customizable) |
| Specimen Dimensions | ≥150 mm × 94 mm or circular |
| Effective Test Area | 48 cm² |
| Test Gases | O₂, N₂, CO₂, air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ (user-supplied gas sources) |
| Test Pressure Range | −0.1 MPa to +0.1 MPa (standard) |
| Gas Supply Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 28 kg |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | HK-G1 |
| Price | Upon Request |
| Measurement Principle | Vacuum-based differential pressure method (ASTM D1434 compliant) |
| Test Gases | O₂, N₂, CO₂, Air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ (hazardous gases require pre-order specification) |
| Standard Test Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C (external chiller/heater required) |
| Temperature Accuracy | ±0.1 °C |
| Sample Thickness | ≤5 mm (customizable) |
| Sample Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Sample Quantity | 1 specimen per test |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Weight | 28 kg |
| Power | AC 220 V, 50 Hz |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HARKE-TQ3 |
| Pricing | Upon Request |
| Measurement Principle | Differential Pressure (Manometric) Method |
| Compliant Standards | ISO 2556:1974, GB/T 1038–2000, ASTM D1434–75 |
| Permeation Rate Range (Chamber A) | 3–6000 cm³/(m²·d·Pa) |
| Permeation Rate Range (Chamber B) | 0.3–600 cm³/(m²·d·Pa) |
| Test Area | 38.46 cm² (Ø70 mm) |
| Specimen Size | 90 mm × 90 mm |
| Specimen Thickness Range | 10 µm – 2 mm |
| Test Gases | O₂, N₂, CO₂ |
| Pressure Differential Range | 0–10⁵ Pa |
| Pressure Measurement Accuracy | ±0.1 Pa |
| Power Supply | AC 220 V, 10 A |
| Control Interface | PC-based Windows software with real-time data logging, curve plotting, report generation (bilingual EN/CN), audit-ready export, and secure file management |
| Brand | HARKE |
|---|---|
| Model | HK-G6 |
| Measurement Principle | Vacuum Method (Manometric) |
| Test Gases | O₂, N₂, CO₂, Air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ |
| Permeation Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C (±0.1 °C) |
| Sample Area | 48 cm² |
| Max Sample Thickness | ≤5 mm |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Chamber | Single independent chamber (configurable to triple-chamber system) |
| Pressure Range | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Power | AC 220 V, 50 Hz |
| Net Weight | 28 kg |
| Dimensions | 330 × 600 × 330 mm (L×D×H) |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Brand | HARKE |
|---|---|
| Model | HK-T103 |
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Measurement Range | 0.01–10⁴ Barrer |
| Resolution | 0.01 Barrer |
| Test Pressure | 0–101 kPa (standard), ±101 kPa (optional) |
| Mass Flow Rate | 0–20 mL/min (standard), 0–200 mL/min (optional) |
| Sample Thickness | ≤2 mm |
| Test Area | 4.9 cm² |
| Sample Capacity | 1 specimen |
| Temperature Control Range | 5–95 °C (±0.1 °C accuracy |
| Humidity Control Range | 0%, 35–90%, 100% RH (±1% RH accuracy |
| Compatible Gases | Air, O₂, N₂, CO₂, He (standard) |
| Gas Inlet | Φ6 mm push-to-connect |
| Dimensions (L×W×H) | 335 × 610 × 340 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 30 kg |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HK-G106 |
| Test Principle | Vacuum Method (Manometric) |
| Measurement Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C (external chiller/heater required) |
| Temperature Accuracy | ±0.1 °C |
| Sample Thickness | ≤5 mm (customizable) |
| Sample Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Gases | O₂, N₂, CO₂, air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ (hazardous gases require pre-order specification) |
| Operating Pressure Range | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 28 kg |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HK-CV2 |
| Pricing | Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HK-T700 |
| Pricing | Upon Request |
| Brand | HARKE |
|---|---|
| Model | HK-O3 |
| Application | Vacuum-Method Gas Permeability Testing for Packaging & Barrier Materials |
| Measurement Principle | Differential Pressure (Vacuum Method) per ISO 15105-1 & ASTM D1434 |
| Test Gases | O₂, N₂, CO₂, Air, He, H₂, CH₄, NH₃, etc. |
| OTR Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C (external chiller/heater required) |
| Temp. Stability | ±0.1 °C |
| Specimen Area | 48 cm² |
| Max. Thickness | ≤5 mm |
| Specimen Size | ≥150 mm × 94 mm or circular |
| Test Chamber | Single cavity, pneumatically clamped |
| Operating Pressure Range | –0.1 to +0.1 MPa |
| Supply Pressure | 0.3–1.0 MPa |
| Gas Inlet | Ø8 mm |
| Dimensions | 330 × 600 × 330 mm (L×D×H) |
| Weight | 28 kg |
| Power | AC 220 V, 50 Hz |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Brand | Harke |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Harke Instrument Co., Ltd. |
| Model | HK-R7 |
| Temperature Control Range | 5 °C to 95 °C (external chiller required) |
| Temperature Accuracy | ±0.1 °C |
| Vacuum Resolution | 0.1 Pa |
| Test Area | 48 cm² |
| Sample Thickness Limit | ≤5 mm (customizable) |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Gas Permeation Range | 0.05–160,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Test Gases | O₂, N₂, CO₂, air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ (hazardous gases require pre-order specification) |
| Operating Pressure Range | −0.1 to +0.1 MPa |
| Supply Pressure | 0.3–1.0 MPa |
| Inlet Port | Ø8 mm |
| Power | AC 220 V, 50 Hz |
| Net Weight | 28 kg |
| Dimensions | 330 mm (L) × 600 mm (D) × 330 mm (H) |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Brand | HARKE |
|---|---|
| Model | HK-398A |
| Measurement Range | 0.01–1200 g/m²·24h (standard), up to 7500 g/m²·24h (optional) |
| Resolution | 0.001 g/m²·24h |
| Temperature Control Range | 5–95°C |
| Temperature Accuracy | ±0.1°C |
| Humidity Control | 0%RH, 35–90%RH, 100%RH |
| Humidity Accuracy | <±1%RH |
| Sample Quantity | 1–6 independent stations |
| Test Area | 38 cm² (standard) |
| Sample Dimensions | 150 mm × 94 mm or circular |
| Max Sample Thickness | ≤5 mm |
| Carrier Gas | 99.999% high-purity N₂ (user-supplied) |
| Gas Pressure | ≥0.16 MPa |
| Gas Flow Rate | 0–200 mL/min |
| Gas Inlet | 1/8″ metal tubing |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 650 × 690 × 415 mm |
| Net Weight | 80 kg |
| Brand | HARKE |
|---|---|
| Model | HK-T03 |
| Type | Vacuum-Method Gas Permeability Tester for Films and Containers |
| Measurement Principle | Coulometric Sensor Detection (ASTM D3985 / ISO 15105-2 Compliant) |
| OTR Range (Film) | 0.01–6500 cm³/m²·d (Standard), 0.05–65,000 cm³/m²·d (Optional) |
| OTR Range (Container) | 0.0001–65 cm³/pkg·d (Standard) |
| Resolution (Film) | 0.001 cm³/m²·d |
| Resolution (Container) | 0.00001 cm³/pkg·d |
| Temperature Control Range | 5–95 °C (External Chiller Required) |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control | 0% RH, 35–90% RH, 100% RH |
| RH Accuracy | ±1% RH |
| Test Area | 50 cm² |
| Sample Thickness Limit | ≤5 mm |
| Sample Dimensions (Film) | ≥150 mm × 94 mm or circular |
| (Container) | ≤Φ120 mm × 400 mm (H) |
| Carrier Gas | 99.999% high-purity N₂ |
| Carrier Flow Rate | 0–200 mL/min |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Net Weight | 28 kg |
| Gas Compatibility | O₂, CO₂, N₂, air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ (hazardous gases require pre-installation safety review) |
| Brand | HARKE |
|---|---|
| Model | HK-O-3 |
| Type | Gas Permeability Tester (O₂, CO₂, N₂, Air, He) |
| Origin | Beijing, China |
| Manufacturer | HARKE Instrument Co., Ltd. |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 730 × 590 × 350 mm |
| Net Weight | 56 kg |
| Test Area | 50 cm² |
| Sample Thickness Limit | ≤5 mm |
| Temperature Range | 5–95 °C (±0.1 °C accuracy) |
| Humidity Control | 0 %RH, 35–90 %RH, 100 %RH (±1 %RH accuracy) |
| OTR Range (Film) | 0.01–6500 cm³/m²·d (standard), 0.05–65000 cm³/m²·d (optional) |
| OTR Range (Container) | 0.0001–65 cm³/pkg·d (standard) |
| Resolution (Film) | 0.001 cm³/m²·d |
| Resolution (Container) | 0.00001 cm³/pkg·d |
| Sample Capacity | 1–3 independent stations |
| Carrier Gas | 99.999% high-purity N₂ (user-supplied) |
| Carrier Flow | 0–200 mL/min |
| Gas Inlet | 1/8″ stainless steel tubing |
| Test Gases | O₂, CO₂, N₂, air, He (user-supplied) |
| Sample Format | Flat films (≥150 mm × 94 mm or circular), containers (≤Φ120 mm × 400 mm H) |