- All
- Favorite
- Popular
- Most rated
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | GTR-3 |
| Pricing | Upon Request |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HK-XR-14Q |
| Price | Upon Request |
| Stirring Speed | 14,000 rpm ± 200 rpm |
| Temperature Control Range | 35 °C ± 1 °C (sample) |
| Operating Ambient | 10–40 °C, <85% RH |
| Stirrer Disc Diameter (Natural Rubber Latex) | 20.83 ± 0.03 mm |
| Stirrer Disc Diameter (Synthetic Rubber Latex) | 36.12 ± 0.03 mm |
| Disc Thickness | 1.57 ± 0.05 mm |
| Stirrer Tip Diameter | 6.3 mm |
| Sample Container | Cylindrical Glass Vessel (ID 58 mm, OD 63 mm, H > 100 mm) |
| Speed Resolution | 1 rpm |
| Speed Accuracy | ≤0.1% |
| Max Speed | 20,000 rpm |
| Min Speed | 2,000 rpm |
| Power Supply | 220 V ±10%, 50 Hz, 1500 W |
| Dimensions (W×D×H) | 400 × 350 × 720 mm |
| Cooling System | Integrated Water Circulation Pump |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Goniometer |
| Measurement Principle | Optical Imaging & Contour Analysis |
| Contact Angle Range | 0–180° |
| Contact Angle Resolution | ±0.01° |
| Contact Angle Accuracy | ±0.1° |
| Surface/Interfacial Tension Range | 0–1000 mN/m |
| Optical System | 0.7×–5× Motorized Zoom Lens with Fixed-Position Calibration |
| High-Speed Imaging | USB 3.0 Camera (30 fps standard |
| Sample Stage Dimensions | 100 mm × 120 mm |
| Lens Vertical Travel | 30 mm |
| Syringe Dispenser Travel | 30 mm |
| Positioning Accuracy (Motorized XYZ) | ±0.1 mm |
| Software | SPCA 1.0 (Windows-based, GLP-compliant data logging) |
| Power Supply | 220 V, 3 A, 50 Hz |
| Dimensions (W×D×H) | 300 mm × 760 mm × — mm |
| Weight | 30 kg |
| Measurement Methods | Circle Fitting, Ellipse Fitting, Height-Width Method, and 5 Additional Algorithmic Models (Total 8) |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | HK-W2 |
| Pricing | Upon Request |
| Brand | HARKE |
|---|---|
| Model | SPCA-Z |
| Type | Benchtop Video Optical Contact Angle Meter |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.5° |
| Stage Dimensions | 100 mm × 120 mm |
| Optical Magnification | 0.7×–4.5× |
| Surface/Interfacial Tension Range | 0–1000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Imaging Frame Rate | Up to 1000 fps (configurable via USB 3.0 camera) |
| Software | SPCA 1.0 |
| Measurement Methods | Circle, Ellipse, Height-Width, and 5 additional geometric fitting algorithms |
| Sample Stage Positioning Accuracy | ±0.1 mm |
| Syringe Dispenser Travel | 30 mm |
| Lens Vertical Travel | 30 mm |
| Power Supply | 220 V, 3 A, 50 Hz |
| Operating Temperature | Ambient |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | HK-10 |
| Instrument Class | Video Optical Contact Angle Meter |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Dimensions | 100 × 100 mm |
| Optical Magnification | 0.5×–0.7× (Stepped Zoom Lens) |
| Surface/Interfacial Tension Range | 0–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Measurement Methods | Sessile Drop, Captive Bubble, Immersion, Tilting Plate (Sliding Angle), Expansion/Contraction, Rolling-off |
| Surface Tension Methods | Pendant Drop, Ring (Du Noüy), Wilhelmy Plate, Maximum Bubble Pressure, Drop Volume |
| Software | HKCA10 v3.x |
| Camera Interface | USB 3.0 |
| Frame Rate | Up to 1000 fps (Optional High-Speed Modules) |
| Power Supply | 220 V / 3 A / 50 Hz |
| Operating Temperature | Ambient (Optional Thermostatic or Heated Stage) |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | SPCA-GZ1 |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Dimensions | 1200 × 250 × 300 mm |
| Optical Magnification | 0.7×–4.7× |
| Surface/Interfacial Tension Range | 0–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Temperature Range | Ambient to 1300 °C (up to 1600 °C with optional configuration) |
| Vacuum Level | ≤1×10⁻⁴ atm (4×10⁻⁴ atm at ambient |
| Heating Zone Length | 300 mm |
| Isothermal Zone Length | >150 mm |
| Max. Heating Power | >1.5 kW |
| Furnace Internal Diameter | Ø40 mm |
| Control Precision | ±1 °C |
| Compatible Atmospheres | Inert gas (Ar, N₂), reduced-oxygen environment |
| Imaging System | High-resolution CCD camera with monochromatic LED illumination and continuous zoom objective |
| Software | Dedicated contact angle analysis suite with automated sessile drop, tilting plate (roll-off), and immersion method protocols |
| Compliance | Designed for GLP-compliant workflows |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | XJL-300C |
| Quotation | Upon Request |
| Ambient Temperature Range | 10–35 °C |
| Hammer Mass Range | 0.250–15.00 kg (increments of 0.100 kg and 0.250 kg |
| certified masses | 1.000 kg and 2.000 kg with ±0.1% accuracy) |
| Hammer Nose Radii | R5 mm, R10 mm, R12.5 mm, R30 mm, R50 mm |
| Impact Height Range | 50–2000 mm (height indication error ≤ ±2 mm) |
| Specimen Diameter Capacity | Φ10–Φ630 mm |
| Power Supply | 220 V AC ±10%, 50 Hz, 500 W (single-phase, three-wire) |
| Lifting Speed | 12 m/min |
| Overall Dimensions | 850 mm × 950 mm × 3350 mm |
| Brand | HARKE |
|---|---|
| Model | SPCA |
| Type | Benchtop Video Optical Contact Angle Meter |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Display Resolution | ±0.01° |
| Surface/Interfacial Tension Range | 0–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 100 mm × 120 mm |
| Optical System | ZF-180 High-Resolution Parfocal Zoom Lens |
| Video Capture Rate | 30 fps (optional: 100/300/1000+ fps) |
| Lens Vertical Travel | 120 mm |
| Instrument Dimensions | 260 mm × 700 mm × — mm (height not specified) |
| Weight | ~30 kg |
| Power Supply | 220 V / 3 A / 50 Hz |
| Operating Temperature | Ambient |
| Surface Energy Method | Equation of State (EOS) |
| Supported Analysis Methods | Circle, Ellipse, Young-Laplace Fitting, Sessile Drop, Captive Bubble, Immersion, Tilting Plate, Squeeze/Expansion, Rolling Drop, Dynamic Contact Angle |
| Software | HARKE-SPCA v1.0 |
| Compliance | GB/T 24368–2009 (Glass Surface Hydrophobic Contaminant Detection by Contact Angle Measurement) |
| Optional Accessories | Electrically Heated Stage, Motorized Tilt Platform |
| Brand | HARKE |
|---|---|
| Model | HK-SPCA1 |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Stage Dimensions | 400 × 400 mm |
| Optical Magnification | 0.7×–4.5× |
| Surface/Interfacial Tension Range | 0–100 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Imaging Speed | Up to 1000 fps (optional) |
| Imaging Interface | USB 2.0 |
| Lens Travel | 120 mm |
| Power Supply | 220 V / 3 A / 50 Hz |
| Weight | ~30 kg |
| Software | HARKE-SPCA1.0 |
| Temperature Control | Ambient (optional electrically heated stage & motorized tilt platform) |
| Brand | HARKE |
|---|---|
| Model | HK-SPCA-1 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Measurement Accuracy | ±0.1° |
| Contact Angle Display Resolution | 0.01° |
| Sample Stage Dimensions | 400 mm × 400 mm |
| Optical Zoom Magnification | 0.7×–4.5× |
| Surface/Interfacial Tension Measurement Range | 0–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Imaging System | USB 2.0 High-Speed Camera (30 fps standard |
| Lens Travel | 120 mm |
| Dimensions (W×D×H) | 260 mm × 700 mm × — mm |
| Weight | ~30 kg |
| Power Supply | 220 V / 3 A / 50 Hz |
| Operating Temperature | Ambient |
| Surface Energy Calculation Method | Equation of State (EOS) |
| Fitting Algorithms | Circle, Ellipse, Young-Laplace, Sessile Drop, Captive Bubble, Tilting Plate |
| Tension Method | Pendant Drop |
| Software Version | HARKE-SPCA 1.0 |
| Brand | HARKE |
|---|---|
| Model | SPCA |
| Type | Benchtop Video Optical Contact Angle Analyzer |
| Origin | Beijing, China |
| Manufacturer | HARKE (Domestic Producer) |
| Measurement Range | 0–180° |
| Accuracy | ±0.1° |
| Droplet Formation Methods | Sessile Drop, Captive Bubble |
| Analysis Algorithms | Automatic Circle Fitting, Ellipse Fitting, Full-Profile Tangent, Local-Profile Tangent, Height/Width Method, Young–Laplace Fitting, Curve Ruler Method |
| Surface Adaptability | Convex/Concave Surfaces, Tilted Substrates, Curvature Correction |
| Dynamic Contact Angle Capability | Yes |
| Image Processing Modes | Manual & Fully Automated |
| Syringe Dispensing Volume | 0–100 µL (Computer-Controlled), 1 mL (Manual) |
| Dispensing Precision | ±0.1 µL |
| Surface Energy Models | Zisman Plot, Fowkes, Owens–Wendt–Rabel–Kaelble (OWRK) |
| Microscope | 0.75×–4.5× Continuous Zoom, Parfocal Design (HARKE Custom) |
| Camera | High-Resolution CMOS Digital Imaging System |
| Video Capture | Real-Time Recording, Frame-by-Frame Playback, Timed Snapshot Capture, Single-Frame Export from Video |
| Stage Dimensions | 100 mm × 120 mm |
| Stage Travel | Vertical 50 mm, Horizontal (X/Y) 70 mm × 40 mm |
| Stage Extension | 30 mm (Vertical Fine Adjustment) |
| Fixed Mount Translation | 150 mm (Z-axis) |
| Syringe Holder Travel | 100 mm × 100 mm (Vertical/Horizontal) |
| Microscope Translation | 100 mm (Z-axis) |
| Max Sample Size | 100 mm (W) × 80 mm (D) × Unrestricted Height |
| Overall Dimensions | 240 mm (W) × 640 mm (D) × 630 mm (H) |
| Brand | HARKE |
|---|---|
| Model | HK-701R |
| Principle | Vacuum Method (ASTM D3985, ISO 15105-2) |
| Test Range | 0.007–190,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Sample Count | 1–3 independent stations |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH, 2–98.5% RH, 100% RH (optional humidity generator) |
| Humidity Accuracy | ±1% RH |
| Max Sample Thickness | ≤5 mm (customizable) |
| Sample Size | ≥150 mm × 94 mm or circular |
| Effective Test Area | 48 cm² |
| Test Gases | O₂, N₂, CO₂, air, He (user-supplied gas source) |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Dimensions (L×W×H) | 730 × 510 × 350 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 63 kg |
| Brand | HARKE |
|---|---|
| Model | SFT-1 |
| Measurement Principle | Wilhelmy Plate Method (Dynamical & Static) |
| Measurement Range | 0–400 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.1 mN/m |
| Temperature Display Range | 0–95 °C |
| Temperature Display Accuracy | ±0.1 °C |
| Sensor Capacity | 0–120 g |
| Sample Stage Vertical Speed | 0–10 mm/s |
| Sample Stage Travel Distance | 0–80 mm |
| Stage Positioning Accuracy | ±0.1 mm |
| Sample Vessel Diameter | Φ50 mm |
| Software | SFT-Al v3.2 |
| Dimensions (W×D×H) | 360 × 360 × 620 mm |
| Net Weight | 20 kg |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | SFT-A1 |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Measurement Accuracy | ±0.01° |
| Sample Stage Diameter | 60 mm |
| Surface/Interfacial Tension Measurement Range | 0–400 mN/m |
| Surface/Interfacial Tension Measurement Accuracy | ±0.1 mN/m |
| Surface/Interfacial Tension Display Resolution | ±0.01 mN/m |
| Force Sensor Capacity | 0–120 g |
| Vertical Stage Speed | 0–10 mm/s |
| Vertical Stage Travel Distance | 0–80 mm |
| Vertical Stage Positioning Accuracy | ±0.1 mm |
| Sample Vessel Dimensions | Φ50 mm |
| Software | SFT-A |
| Operating Temperature | Ambient |
| Dimensions (L×W×H) | 360 × 360 × 620 mm |
| Weight | 20 kg |
| Optional Accessories | Electrically Heated Thermostatic Circulation Jacket |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | HARKE-SPCA-1 |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Measurement Accuracy | ±0.1° |
| Contact Angle Display Resolution | 0.01° |
| Sample Stage Dimensions | 400 mm × 400 mm |
| Optical Magnification | 0.7×–4.5× |
| Surface/Interfacial Tension Measurement Range | 0–1000 mN/m |
| Surface/Interfacial Tension Measurement Accuracy | ±0.01 mN/m |
| Imaging System | USB 2.0 High-Speed Camera (30 fps standard |
| Lens | ZF-180 Precision Stepping Zoom Lens with 120 mm Vertical Travel |
| Software | HARKE-SPCA v1.0 |
| Surface Energy Analysis Method | Equation of State (EOS), Circle, Ellipse, and Small-Drop Fitting Algorithms |
| Power Supply | 220 V / 3 A / 50 Hz |
| Operating Temperature | Ambient |
| Weight | ~30 kg |
| Dimensions (W × D × H) | 260 mm × 700 mm × — mm (height not specified) |
| Brand | HARKE |
|---|---|
| Model | HK-T-391 |
| Origin | Beijing, China |
| Manufacturer | Yes |
| Type | Domestic |
| Measurement Range | 1×10⁻⁵ – 1×10⁻¹⁴ cm³(STP)·mm/cm²·s·cmHg |
| Test Method | TCD Detection + Chromatographic Calibration Curve |
| Max Sample Thickness | ≤1 mm |
| Detection Sensitivity | ≥3000 mV·mL/mg (for benzene & H₂) |
| Test Area | 50 cm² |
| Sample Capacity | 1 standard specimen (multi-specimen option available) |
| Test Chamber Temp. Range | 5–95 °C |
| Temp. Control Accuracy | ±0.1 °C |
| Carrier Gas Line Temp. Range | RT+5–100 °C |
| Carrier Gas | He or H₂ (selectable) |
| Carrier Pressure | 0.05–0.5 MPa |
| Test Gas Pressure Differential | −0.1 to +0.1 MPa |
| Vacuum Level in Test Chamber | <20 Pa |
| Applicable Gases | Air, O₂, N₂, CO, CO₂, CH₄, H₂, He, NH₃, C₃H₈, C₄H₁₀ (custom gases available |
| Dimensions | 330 × 380 × 410 mm (L×W×H) |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 46 kg |
| Compliance | GB/T 1038, ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, YBB00082003 |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HK-100T |
| Pricing | Available Upon Request |
| Brand | HARKE |
|---|---|
| Model | XR-14T |
| Origin | Beijing, China |
| Manufacturer | HARKE Instrument Co., Ltd. |
| Type | Domestic Production |
| Speed Range | 3,000–20,000 rpm (standard test speed: 14,000 ± 200 rpm) |
| Stirring Disk Dimensions (Natural Latex) | Ø20.83 ± 0.03 mm × 1.57 ± 0.05 mm |
| Stirring Disk Dimensions (Synthetic Latex) | Ø36.12 ± 0.03 mm × 1.58 ± 0.05 mm |
| Container Internal Diameter | 58 ± 0.25 mm |
| Container Height | 127 mm |
| Wall Thickness | 2.5 mm |
| Disk-to-Bottom Distance | 13 ± 1 mm |
| Power Supply | 220 V ± 10%, 5 A |
| Operating Temperature | 10–40 °C |
| pH Compatibility | 1–14 |
| Cooling Option | Circulating water jacket (optional) |
| Compliance | ISO 2006 |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic (China-made) |
| Model | HARKE-PV35S |
| Instrument Class | Video Optical Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Dimensions | 350 mm × 350 mm |
| Optical Magnification | 0.75×–4.5× (parfocal zoom) |
| Surface/Interfacial Tension Range | 0–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | HK-701M |
| Measurement Principle | Vacuum-Pressure Differential Method |
| Test Gases | O₂, CO₂, N₂, Air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ |
| Test Range | 0.01–150,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Sample Capacity | 1–3 independent chambers |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range (optional) | 0%RH, 2–98.5%RH, 100%RH |
| Humidity Accuracy | ±1%RH |
| Max Sample Thickness | ≤5 mm |
| Sample Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Gas Supply Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Dimensions (L×W×H) | 730 × 510 × 350 mm |
| Weight | 63 kg |
| Compliance | GB/T 1038–2000, ISO 15105-1, ISO 2556, ASTM D1434, JIS K 7126-1, YBB 00082003 |
| Brand | HARKE |
|---|---|
| Model | SPCA |
| Type | Benchtop Video Optical Contact Angle Analyzer |
| Origin | Beijing, China |
| Manufacturer | HARKE (Domestic Producer) |
| Measurement Range | 0–180° |
| Accuracy | ±0.1° |
| Droplet Formation Methods | Sessile Drop, Captive Bubble |
| Analysis Algorithms | Automated Circle Fitting, Ellipse Fitting, Full-Profile Tangent, Local-Profile Tangent, Height/Width Method, Young–Laplace Fitting, Curve Ruler Method |
| Surface Adaptability | Convex/Concave Surfaces, Tilted Substrates, Curvature Correction |
| Dynamic Contact Angle Capability | Advancing/Receding/Average |
| Image Processing | Manual & Fully Automated |
| Syringe Dispensing | Computer-Controlled (0–100 μL), Manual (1 mL) |
| Dispensing Precision | ±0.1 μL |
| Surface Energy Models | Zisman Plot, Fowkes, Owens–Wendt–Rabel–Kaelble (OWRK) |
| Microscope | HARKE-Optimized Precision Zoom Lens (0.75×–4.5×, Parfocal) |
| Camera | High-Resolution Digital CMOS |
| Video Capture | Real-Time Recording, Frame-by-Frame Playback, Timed Auto-Capture, Single-Frame Export from Video |
| Stage Dimensions | 100 mm × 120 mm |
| Stage Travel | Vertical 50 mm, Horizontal (X/Y) 70 mm / 40 mm |
| Stage Extension | 30 mm |
| Fixed Base Translation | 150 mm (Z-axis) |
| Dispenser Translation | 100 mm (X/Y) |
| Microscope Translation | 100 mm (Z-axis) |
| Max Sample Size | 100 mm (W) × 80 mm (D) × Unlimited Height |
| Overall Dimensions | 240 mm (W) × 640 mm (D) × 630 mm (H) |
| Brand | HARKE |
|---|---|
| Model | SPCAX1 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Dimensions | 120 mm × 120 mm |
| Optical Magnification | 0.7×–4.7× (parfocal zoom) |
| Surface/Interfacial Tension Range | 0–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Automated Dispensing Volume | 0–100 μL (computer-controlled), ±0.1 μL precision |
| Manual Syringe Capacity | 1 mL |
| Imaging System | High-resolution CMOS camera with real-time video capture, frame-by-frame playback, time-lapse snapshot, and single-frame export |
| Stage Mobility | Vertical: 50 mm |
| Horizontal (X/Y) | 70 mm × 40 mm |
| Fixed Plate Translation | 150 mm (Z-axis) |
| Dispenser Travel | 100 mm × 100 mm |
| Microscope Translation | 100 mm (Z-axis) |
| Max Sample Dimensions | 100 mm (W) × 80 mm (D) × variable height |
| Overall Dimensions | 240 mm (W) × 640 mm (D) × 630 mm (H) |
| Brand | HARKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Domestic Product | Yes |
| Model | HK-V3 |
| Pricing | Upon Request |
Show next