Empowering Scientific Discovery

Beijing Haonuos Science & Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ModelHERAcell 150i
Temperature Range & Accuracy3–55 °C
Temperature Uniformity±0.5 °C
Humidity Control>99.5% RH (non-condensing)
Chamber Capacity150 L
Sterilization MethodContraCon 90 °C moist-heat
CO₂ Sensing OptionsThermal Conductivity (TC) or Dual-Beam Infrared (IR)
Optional O₂ Control Range1–21% or 5–90%
Interior MaterialElectropolished stainless steel (optional 100% pure copper)
Door ConfigurationTriple-pane tempered glass inner doors (3-door configuration for 150 L)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Model3404 Midi 40TM
Chamber Volume39.6 L
Temperature RangeAmbient +5°C to 60°C
Temperature Uniformity (at 37°C)±0.4°C
Temperature Accuracy±0.1°C
CO₂ Control Range0–20%
CO₂ Control AccuracyBetter than ±0.1%
Relative Humidity (at 37°C)Up to 95%
Internal Dimensions (W×H×D)30.5 × 35.5 × 35.5 cm
External Dimensions (W×H×D)47 × 46.5 × 59.7 cm
Shelf Quantity4
Sensor TypeIn-chamber TC sensor for CO₂
Net Weight27 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Model3110 Series
Chamber Volume184.1 L
Water Jacket Capacity43.5 L
Temperature RangeAmbient +5°C to 55°C
Temperature Uniformity (at 37°C)±0.2°C
Temperature Accuracy±0.1°C
CO₂ Range0–20%
CO₂ Control AccuracyBetter than ±0.1%
O₂ Range1–20%
O₂ Sensor TypeFuel Cell
Relative Humidity (at 37°C)Ambient to 95% RH
Humidification Pan Capacity3.0 L
Internal Dimensions (W×H×D)544 × 681 × 508 mm
External Dimensions (W×H×D)668 × 1003 × 635 mm
Standard Shelving4 shelves (max 17)
Net Weight120 kg
HEPA FiltrationClass 100 internal environment
Power Input Pressure15 PSIG
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Model310 Series
Temperature Range5°C above ambient to 50°C
Temperature Uniformity (at 37°C)±0.2°C
Temperature Accuracy±0.1°C
CO₂ Range0–20%
CO₂ Control AccuracyBetter than ±0.1%
Relative Humidity (at 37°C)Ambient RH to 95%
Humidification Pan Capacity3.0 L (standard)
Internal Volume184.1 L
Internal Dimensions (W×H×D)544 × 681 × 508 mm
External Dimensions (W×H×D)663 × 978 × 627 mm
Input Pressure15 PSIG
CO₂ Sensor TypeThermal Conductivity (T/C) or Infrared (IR)
Standard/Maximum Shelving4 / 17 shelves
Net Weight96 kg
Air FiltrationHEPA Filter, Class 100 Internal Environment
Control SystemEnviro-Scan™ Microprocessor-Based Environmental Monitoring and Control System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Model3951
Temperature RangeAmbient +5°C to 60°C
CO₂ Range0–20%
CO₂ Control Accuracy±0.1%
Temperature Uniformity (at 37°C)±0.3°C
Temperature Control Accuracy±0.1°C
Humidity OptionsOff / Medium (>80%) / High (>90%)
Internal Volume821.2 L
Internal Dimensions (W×H×D)787 × 1524 × 686 mm
External Dimensions (W×H×D)965 × 2032 × 838 mm
Shelf Capacity5 standard / up to 27 stainless steel shelves
Total Shelving Area13.5 m²
Humidity Reservoir Volume15.1 L
CO₂ Sensor TypeThermal Conductivity (T/C)
Input Gas Pressure15 PSIG
Heated Inner Glass DoorYes
Dual External Port Access (Left/Right)Yes
Power Fail Memory for Setpoints & Calibration ValuesYes
Automatic CO₂ Cut-off on Outer Door OpeningYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Model3308 / 3311
Temperature RangeAmbient +5°C to 50°C
CO₂ Range0–20%
CO₂ Control Accuracy±0.1%
Temperature Uniformity (at 37°C)±0.2°C
Temperature Accuracy±0.1°C
Humidity Range (at 37°C)Ambient RH to 95% RH, non-condensing
Humidity Control Accuracy±2.0%
Humidity Reservoir Capacity3.8 L
Internal Volume232 L (3308) / 323 L (3311)
External Dimensions (W×H×D, mm)889×1001×686 (3308) / 1092×1001×686 (3311)
Internal Dimensions (W×H×D, mm)528×833×523 (3308) / 732×833×523 (3311)
Shelf Capacity5 standard / up to 22 shelves
CO₂ Sensor TypeDual-beam Infrared (IR)
Sterilization Method140°C Dry-Heat Decontamination
Air FiltrationClass 100 HEPA Recirculation (1 air change per minute)
Humidity DeliveryExternal Water Reservoir with Microprocessor-Controlled Steam Generator
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Model370 Series
Temperature RangeAmbient +5°C to 50°C
Temperature Uniformity (at 37°C)±0.3°C
Temperature Control Accuracy±0.1°C
CO₂ Control AccuracyBetter than ±0.1%
CO₂ Sensor TypeThermocouple (T/C) or Infrared (IR)
Humidity Range (at 37°C)Ambient RH to 95% RH
Humidification Reservoir Capacity3.0 L (standard)
Internal Volume184.1 L
Internal Dimensions (W×H×D)540 × 681 × 508 mm
External Dimensions (W×H×D)663 × 1003 × 635 mm
Standard Shelf Quantity4
Net Weight118 kg
Sterilization Cycle Duration~14 h (including preheat, sterilization at ≥180°C, and cool-down)
Air Exchange RateOne full internal air exchange per minute via Class 100 HEPA filtration
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0