| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | HERAcell 150i |
| Temperature Range & Accuracy | 3–55 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Control | >99.5% RH (non-condensing) |
| Chamber Capacity | 150 L |
| Sterilization Method | ContraCon 90 °C moist-heat |
| CO₂ Sensing Options | Thermal Conductivity (TC) or Dual-Beam Infrared (IR) |
| Optional O₂ Control Range | 1–21% or 5–90% |
| Interior Material | Electropolished stainless steel (optional 100% pure copper) |
| Door Configuration | Triple-pane tempered glass inner doors (3-door configuration for 150 L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | 3404 Midi 40TM |
| Chamber Volume | 39.6 L |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Uniformity (at 37°C) | ±0.4°C |
| Temperature Accuracy | ±0.1°C |
| CO₂ Control Range | 0–20% |
| CO₂ Control Accuracy | Better than ±0.1% |
| Relative Humidity (at 37°C) | Up to 95% |
| Internal Dimensions (W×H×D) | 30.5 × 35.5 × 35.5 cm |
| External Dimensions (W×H×D) | 47 × 46.5 × 59.7 cm |
| Shelf Quantity | 4 |
| Sensor Type | In-chamber TC sensor for CO₂ |
| Net Weight | 27 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 3110 Series |
| Chamber Volume | 184.1 L |
| Water Jacket Capacity | 43.5 L |
| Temperature Range | Ambient +5°C to 55°C |
| Temperature Uniformity (at 37°C) | ±0.2°C |
| Temperature Accuracy | ±0.1°C |
| CO₂ Range | 0–20% |
| CO₂ Control Accuracy | Better than ±0.1% |
| O₂ Range | 1–20% |
| O₂ Sensor Type | Fuel Cell |
| Relative Humidity (at 37°C) | Ambient to 95% RH |
| Humidification Pan Capacity | 3.0 L |
| Internal Dimensions (W×H×D) | 544 × 681 × 508 mm |
| External Dimensions (W×H×D) | 668 × 1003 × 635 mm |
| Standard Shelving | 4 shelves (max 17) |
| Net Weight | 120 kg |
| HEPA Filtration | Class 100 internal environment |
| Power Input Pressure | 15 PSIG |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 310 Series |
| Temperature Range | 5°C above ambient to 50°C |
| Temperature Uniformity (at 37°C) | ±0.2°C |
| Temperature Accuracy | ±0.1°C |
| CO₂ Range | 0–20% |
| CO₂ Control Accuracy | Better than ±0.1% |
| Relative Humidity (at 37°C) | Ambient RH to 95% |
| Humidification Pan Capacity | 3.0 L (standard) |
| Internal Volume | 184.1 L |
| Internal Dimensions (W×H×D) | 544 × 681 × 508 mm |
| External Dimensions (W×H×D) | 663 × 978 × 627 mm |
| Input Pressure | 15 PSIG |
| CO₂ Sensor Type | Thermal Conductivity (T/C) or Infrared (IR) |
| Standard/Maximum Shelving | 4 / 17 shelves |
| Net Weight | 96 kg |
| Air Filtration | HEPA Filter, Class 100 Internal Environment |
| Control System | Enviro-Scan™ Microprocessor-Based Environmental Monitoring and Control System |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 3951 |
| Temperature Range | Ambient +5°C to 60°C |
| CO₂ Range | 0–20% |
| CO₂ Control Accuracy | ±0.1% |
| Temperature Uniformity (at 37°C) | ±0.3°C |
| Temperature Control Accuracy | ±0.1°C |
| Humidity Options | Off / Medium (>80%) / High (>90%) |
| Internal Volume | 821.2 L |
| Internal Dimensions (W×H×D) | 787 × 1524 × 686 mm |
| External Dimensions (W×H×D) | 965 × 2032 × 838 mm |
| Shelf Capacity | 5 standard / up to 27 stainless steel shelves |
| Total Shelving Area | 13.5 m² |
| Humidity Reservoir Volume | 15.1 L |
| CO₂ Sensor Type | Thermal Conductivity (T/C) |
| Input Gas Pressure | 15 PSIG |
| Heated Inner Glass Door | Yes |
| Dual External Port Access (Left/Right) | Yes |
| Power Fail Memory for Setpoints & Calibration Values | Yes |
| Automatic CO₂ Cut-off on Outer Door Opening | Yes |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 3308 / 3311 |
| Temperature Range | Ambient +5°C to 50°C |
| CO₂ Range | 0–20% |
| CO₂ Control Accuracy | ±0.1% |
| Temperature Uniformity (at 37°C) | ±0.2°C |
| Temperature Accuracy | ±0.1°C |
| Humidity Range (at 37°C) | Ambient RH to 95% RH, non-condensing |
| Humidity Control Accuracy | ±2.0% |
| Humidity Reservoir Capacity | 3.8 L |
| Internal Volume | 232 L (3308) / 323 L (3311) |
| External Dimensions (W×H×D, mm) | 889×1001×686 (3308) / 1092×1001×686 (3311) |
| Internal Dimensions (W×H×D, mm) | 528×833×523 (3308) / 732×833×523 (3311) |
| Shelf Capacity | 5 standard / up to 22 shelves |
| CO₂ Sensor Type | Dual-beam Infrared (IR) |
| Sterilization Method | 140°C Dry-Heat Decontamination |
| Air Filtration | Class 100 HEPA Recirculation (1 air change per minute) |
| Humidity Delivery | External Water Reservoir with Microprocessor-Controlled Steam Generator |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 370 Series |
| Temperature Range | Ambient +5°C to 50°C |
| Temperature Uniformity (at 37°C) | ±0.3°C |
| Temperature Control Accuracy | ±0.1°C |
| CO₂ Control Accuracy | Better than ±0.1% |
| CO₂ Sensor Type | Thermocouple (T/C) or Infrared (IR) |
| Humidity Range (at 37°C) | Ambient RH to 95% RH |
| Humidification Reservoir Capacity | 3.0 L (standard) |
| Internal Volume | 184.1 L |
| Internal Dimensions (W×H×D) | 540 × 681 × 508 mm |
| External Dimensions (W×H×D) | 663 × 1003 × 635 mm |
| Standard Shelf Quantity | 4 |
| Net Weight | 118 kg |
| Sterilization Cycle Duration | ~14 h (including preheat, sterilization at ≥180°C, and cool-down) |