| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | NX-3R Pro |
| Instrument Type | Benchtop Centrifuge |
| Category | High-Speed Refrigerated Centrifuge (10,000–30,000 rpm) |
| Maximum Speed | 21,000 rpm |
| Maximum RCF | 33,500 × g |
| Maximum Capacity | 4 × 250 mL |
| Minimum Temperature | –20 °C |
| Dimensions (W × D × H) | 325 × 470 × 740 mm |
| Rotor Compatibility | Fixed-angle rotors with multiple adapter options |
| Control Interface | 7-inch HD color touchscreen |
| Drive System | Direct-drive inverter motor |
| Safety Features | Electronic imbalance detection, auto rotor recognition, lid interlock, overspeed/overtemperature protection |
| Programmability | 100 user programs, up to 10 segments per program |
| Acceleration/Deceleration | 9-step acceleration, 10-step deceleration |
| Construction | Full metal housing with corrosion-resistant powder coating |
| Refrigeration | Eco-friendly non-CFC compressor system |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | J-Series |
| Pricing | Available Upon Request |
| Brand | DHS |
|---|---|
| Origin | Beijing, China |
| Model | MPC2000 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 4500 rpm |
| Max RCF | 2860 × g |
| Capacity | 6 × 96-well plates (e.g., PCR, ELISA, deep-well plates) |
| Alternate Configurations | 2 × deep-well/PCR plates or 8 × 15 mL conical/tube centrifuge tubes |
| Rotor Options | H-type plate rotor (max height 55 mm), 8-position horizontal tube rotor, and optional 96×0.2 mL PCR plate adapter kit |
| Drive System | Brushless DC motor, direct drive |
| Safety | Electronic lid lock with interlock |
| Operation Modes | Instant spin (short-run), timed run |
| Construction | All-metal housing, stainless-steel chamber |
| Dimensions (W×D×H) | 288 × 384 × 480 mm |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model No. | 0401318 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 300–21,000 rpm |
| Max. RCF | 33,500 × g |
| Max. Capacity | 4 × 1000 mL |
| Temperature Range | −20 °C to +40 °C |
| Acceleration/Deceleration Steps | 9-step acceleration, 10-step deceleration |
| Rotor Recognition | Automatic |
| Programmable Steps | Up to 10 segments per program |
| Total Programs Stored | 100 |
| Display | 10-inch full-color capacitive touchscreen |
| Drive System | Brushless frequency-controlled motor |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 3000 W |
| Dimensions (W×H×D) | 855 × 395 × 730 mm |
| Net Weight | 120 kg |
| Compliance | CE, ISO 13485 (manufacturing), IEC 61010-2-020 |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | PlateSmart |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–2500 rpm |
| Max RCF | 650 × g |
| Max Capacity | 4 × 96-well microplates (e.g., ELISA, cell culture plates) or 2 × deep-well/PCR plates |
| Rotor Type | Fixed-angle horizontal microplate rotor (38 mm plate height clearance) |
| Motor | Brushless DC direct-drive torque motor |
| Control | Microprocessor-based digital display for time and speed |
| Timer Range | 1 s – 99 min 59 s |
| Spin Function | Instant centrifugation (Spin key) |
| Safety | Automatic rotor stop upon lid opening, mechanical safety lock |
| Noise Level | ≤55 dB(A) |
| Dimensions (W×D×H) | 300 × 310 × 380 mm |
| Weight | <12 kg |
| Compliance | Designed per IEC 61010-1 for laboratory equipment safety |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ST16R / ST40R |
| Max Rotor Capacity | 4×750 mL (ST40R, BIOLiner rotor) |
| Max Speed | 15,200 rpm (micro-angle rotors) |
| Max RCF | 25,830 ×g |
| Temperature Range | –10°C to +40°C |
| Acceleration/Deceleration Steps | 9/10 |
| Timer Range | 9 hr 59 min + continuous |
| Noise Level | <61 dBA (ST16R), <61 dBA (ST40R) |
| Refrigeration | CFC-free compressor-based system |
| Motor | Brushless DC induction motor |
| Control System | Microprocessor-driven SMARTSpin® with 6 programmable quick-start protocols |
| Safety Certifications | IEC 61010-1, ISO 13485 compliant design, ClickSeal® biosafety-certified lid locking |
| Rotor Locking | Auto-Lock® III mechanical self-aligning rotor engagement |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | MiniSmart |
| Instrument Type | Benchtop Portable Centrifuge |
| Maximum Speed | 6500 rpm |
| Maximum RCF | 2000 × g |
| Capacity | 6 × 1.5/2 mL tubes or 2 × 8 × 0.2 mL PCR strips |
| Dimensions | 120 × 130 × 140 mm |
| Weight | 0.5 kg |
| Rotor Configuration | Fixed-angle rotors (interchangeable) |
| Intended Use | Routine separation of biological macromolecules (e.g., DNA, RNA, proteins, cell lysates) in low-speed applications |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | NX-1R Pro |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 200–17,500 rpm |
| Max RCF | 23,300 × g |
| Max Capacity | 24 × 1.5/2.0 mL tubes |
| Temperature Range | –20 °C to +40 °C |
| Refrigeration System | Eco-friendly non-CFC compressor |
| Dimensions (W×D×H) | 355 × 270 × 545 mm |
| Display | 5-inch HD color touchscreen |
| Acceleration/Deceleration | 10-step programmable |
| Programs | 100 user-storable, up to 10-segment per program |
| Rotor Options | 5 interchangeable high-speed fixed-angle rotors |
| Tube Compatibility | 0.2–5.0 mL conical, round-bottom, PCR strip tubes, spin columns |
| Safety Features | Electronic lid lock, overspeed protection, overtemperature protection, condensation-resistant chamber |
| Construction | Full metal housing with epoxy powder coating |
| Data Logging | Real-time curve recording and historical run logs |
| Compliance | Designed for GLP-compliant workflows |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WX |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Sorvall LYNX |
| Instrument Type | Floor-standing centrifuge |
| Speed Range | 10,000–29,000 rpm |
| Max RCF | 100,650 × g |
| Max Capacity | 6 × 1000 mL |
| Dimensions (H×D×W) | 930 × 805 × 700 mm |
| Weight | 293 kg |
| Temperature Range | –20 to +40 °C |
| Vacuum System | Intelligent vacuum system with optional HEPA filtration |
| Drive | High-torque brushless motor |
| Rotor Locking | Auto-Lock® |
| Rotor Recognition | Auto-ID® |
| Rotor Material | Fiberlite® carbon fiber |
| Biosafety | ClickSeal® biocontainment lid |
| Acceleration/Deceleration | 9 acceleration / 10 deceleration profiles |
| Run Time | Up to 99 h continuous |
| Pre-cooling | Yes |
| ACE Integrator | Yes |
| Compliance Features | User log, role-based access control, audit trail, automatic door opening, rotor cover handle, integrated training videos, multilingual UI |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | NX-2R |
| Instrument Type | Benchtop Centrifuge |
| Category | High-Speed Refrigerated Centrifuge (10,000–30,000 rpm) |
| Max. Speed | 18,500 rpm |
| Max. RCF | 26,000 × g |
| Max. Capacity | 4 × 100 mL |
| Temperature Range | –20 °C to +40 °C |
| Dimensions (W×D×H) | 360 × 330 × 630 mm |
| Rotor Compatibility | 10 interchangeable rotors (including fixed-angle and PCR strip rotors) |
| Tube Compatibility | 0.2, 1.5, 2.0, 5.0, 15, and 50 mL tubes |
| Safety Features | Electronic lid lock, rotor auto-recognition, overtemperature shutdown, reinforced stainless-steel chamber, thickened metal housing |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Sorvall™ BIOS 16 |
| Instrument Type | Floor-standing centrifuge |
| Speed Range | High-speed (up to 5400 rpm) |
| Cooling Function | Refrigerated centrifuge |
| Configuration | Horizontal rotor centrifuge |
| Separation Level | Cell/bacterial |
| Max Capacity | 8 × 2000 mL |
| Max Speed | 5400 rpm |
| Max RCF | 8500 × g |
| Dimensions (L×W×H) | 900 mm × 816 mm × 1015 mm |
| Weight | 465 kg |
| Temperature Range | −20 °C to +40 °C (adjustable in 1 °C increments) |
| Certifications | UL, CE, FDA-listed |
| Drive Technology | DuraFlex high-torque brushless motor |
| Control Interface | Centri-Touch™ touchscreen |
| Auto-ID | Yes |
| Auto-Door & Auto-Lid | Yes |
| ACE™ (Automatic Centrifugation Efficiency) Integration | Yes |
| Pre-cooling | Yes |
| Imbalance Tolerance | 125 g (opposite loads) |
| Step Runs | Up to 30 speed/time/temperature triplets, max 3 steps per program |
| Warranty | 2 years (unit), 5 years (powertrain & refrigeration) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Legend X1/X1R & XT/XTR |
| Max Rotor Capacity | 4×1000 mL (XT/XTR) / 4×750 mL (X1/X1R) |
| Max Speed | 15,200 rpm |
| Max RCF | 25,830 ×g |
| Temperature Range | –10 °C to +40 °C (X1R/XTR only) |
| Refrigeration | CFC-free compressor-based cooling |
| Drive System | Brushless DC induction motor |
| Rotor Locking | Auto-Lock® III |
| Biosafety | ClickSeal® sealed bucket system |
| Rotor Material | Fiberlite® carbon-fiber composites |
| Control System | SMARTSpin® microprocessor-based interface |
| Programs | 99 stored methods (5 quick-access) |
| Acceleration/Deceleration Profiles | 9/10 selectable |
| Max Run Time | 9 h 59 min + continuous mode |
| Noise Level | <61 dBA (X1), <55 dBA (X1R), <57 dBA (XT/XTR) |
| Chamber | Stainless steel |
| Compliance | IEC 61010-1, IEC 61010-2-020, ISO 13485 (manufacturing), FDA 21 CFR Part 11-ready software architecture |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Model | MSC-Advantage |
| Certification | EN 12469:2000, IEC 61010-1:2001, EN 61010-1:2001, NF S 09-500 Rev. 3.2006, DIN EN 61326-1:2004-05 |
| Filter Efficiency | ≥99.999% @ 0.3 µm (HEPA H14 per EN 1822) |
| Airflow Control | Dual independent fan system with real-time active compensation |
| Work Area Construction | Monolithic U-shaped stainless steel chamber with fully sealed side walls |
| Performance Indicator | Real-time Performance Factor (PF) display on control panel |
| Noise Level | <55 dB(A) (MSC-Advantage 1.2) / <57 dB(A) (MSC-Advantage 1.8) |
| Illumination | >1200 lx |
| Power Consumption | 0.4 kW (1.2 m) / 0.8 kW (1.8 m) |
| Compliance | YY 0569–2005, Low Voltage Directive 73/23/EEC, EMC Directive 89/336/EEC |
| External Dimensions (W×H×D, with stand) | 1300×2200×795 mm (1.2 m) / 1900×2200×795 mm (1.8 m) |
| Front Window Opening Height | 535 mm |
| Net Weight | 240 kg / 340 kg |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | NX-1 Pro |
| Centrifuge Type | Benchtop High-Speed Microcentrifuge |
| Speed Range | 200–17,500 rpm |
| Max RCF | 23,300 × g |
| Max Capacity | 24 × 1.5/2.0 mL tubes |
| Rotor Type | Fixed-Angle |
| Separation Target | Organelles, Viruses, Macromolecular Complexes |
| Dimensions (W×D×H) | 295 × 227 × 395 mm |
| Cooling | None (Non-refrigerated) |
| Compliance | CE, ISO 13485 (Manufacturing), IEC 61010-1 |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | CellSmart |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 2770 × g |
| Max Capacity | 2×10×15 mL, 2×3×50 mL, 2×12×5 mL, 2×21×2 mL, 2×15×10 mL |
| Dimensions (W×D×H) | 384 × 288 × 480 mm |
| Rotor Configuration | Horizontal swing-out rotor |
| Application Scope | Cell & bacterial pelleting |
| Drive System | Brushless DC motor |
| Chamber Material | Stainless steel interior |
| Control Interface | Microprocessor-based with high-brightness LED display |
| Features | Instant spin button, rpm/RCF toggle key, low-noise airflow ducting, ambient temperature stability during operation |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Model | Legend Micro 17 / Legend Micro 17R / Legend Micro 21 / Legend Micro 21R |
| Max RCF | 17,000 × g / 21,000 × g |
| Max Speed | 13,300 rpm / 14,800 rpm |
| Capacity | 24 × 1.5 mL / 2.0 mL tubes |
| Drive System | Brushless frequency-sensing direct-drive motor |
| Temperature Range (Refrigerated models) | –9 °C to 40 °C |
| Noise Level | ≤56 dB(A) |
| Acceleration/Deceleration Time | 11–13 s |
| Safety Features | Automatic rotor recognition, lid interlock, imbalance detection, self-diagnostic system, electronic circuit protection |
| Compliance | IEC 61010-1, EN 61326-1 (EMC), FDA 21 CFR Part 11-ready software architecture |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model No. | 0401321 |
| Type | Benchtop Centrifuge |
| Speed Range | 300–21,000 rpm |
| Max RCF | 33,500 × g |
| Max Capacity | 6 × 250 mL |
| Temperature Range (NX-3R Pro only) | −20 °C to 40 °C |
| Acceleration/Deceleration | 9-step acceleration, 10-step deceleration |
| Rotor Recognition | Automatic |
| Program Storage | 100 user-defined protocols (up to 10 segments per program) |
| Display | 7-inch HD color touchscreen |
| Drive System | Inverter-controlled brushless motor |
| Safety Features | Electronic imbalance detection, lid interlock, overspeed/overtemperature protection |
| Dimensions (NX-3 Pro) | 435 × 330 × 545 mm |
| Weight (NX-3 Pro) | 36 kg |
| Power Supply | 220 V / 50 Hz |
| Rated Power (NX-3 Pro/NX-3R Pro) | 800 W / 1500 W |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | NX-1/1R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 200–17,500 rpm |
| Max RCF | 23,300 × g |
| Max Capacity | 12 × 5 mL tubes |
| Temperature Range | –20 °C to +40 °C |
| Refrigeration System | Eco-friendly non-CFC compressor |
| Dimensions (W×D×H) | 325 × 295 × 540 mm |
| Noise Level | ≤58 dB(A) |
| Rotor Type | Fixed-angle rotor |
| Compliance | CE, ISO 13485 (manufacturing), IEC 61010-1 |
| Certifications | Factory-tested per EN 61010-2-020 for centrifuges |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ST 8 |
| Maximum RCF | 24,328 × g |
| Max Speed | 16,000 rpm |
| Min Speed | 300 rpm |
| Capacity (Horizontal) | 4 × 145 mL |
| Capacity (Fixed-Angle) | 6 × 50 mL |
| Rotor Locking | Auto-Lock® |
| Biosafety Lid | ClickSeal® Certified |
| Control System | Microprocessor-Driven Direct-Drive Induction Motor |
| Acceleration/Deceleration Profiles | 2 (Standard & Soft) |
| Timer Range | 0–9 h 59 min + Continuous |
| Noise Level | <58 dBA (TX-150), <61 dBA (MicroClick 24) |
| Power Consumption | 310 W |
| Dimensions (H×W×D) | 67 cm (lid open) / 31 cm (lid closed) × 37 cm × 48 cm |
| Weight | 35 kg |
| Program Storage | 4 User-Named Protocols with Password Protection |
| Compliance | IEC 61010-1, ISO 13485 (for in vitro diagnostic use), EN 61326-1 (EMC) |