Empowering Scientific Discovery

Beijing Haonuos Science & Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelEG1150H+C
ConfigurationIntegrated Cold Plate (EG1150 C) + Heated Paraffin Dispensing Module (EG1150 H)
Work SurfaceLarge, chemically resistant, non-porous finish
IlluminationAdjustable halogen task lamp with full-workspace coverage
Optional AccessoryArticulating magnifier with variable focus and height adjustment
Paraffin Drainage SystemDual heated paraffin collection trays (removable, 2.5 L capacity each)
Warming TraysInterchangeable cassette and mold warming plates (independent temperature control, range: 37–65 °C)
Workflow FlexibilityBidirectional layout compatibility (left-to-right or right-to-left configuration)
ComplianceDesigned in accordance with IEC 61010-1 (Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use) and ISO 13485:2016 (Medical Devices – Quality Management Systems)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDHS
OriginTianjin, China
ModelTL3000/TL2010S
Sample TypeCryogenic-compatible (liquid nitrogen pre-cooled)
Max. Oscillation Speed2000 rpm
Input Particle Size≤8 mm
Output Particle Size≤5 µm
Throughput Capacity2 × 12 × 2 mL tubes, 2 × 6 × 4/5 mL rigid tubes, 2 × 15 mL grinding jars
Grinding PrincipleHorizontal 3D oscillation with bead impact
Compatible Grinding MediaStainless steel / tungsten carbide / zirconia beads (1–8 mm diameter)
Jar/Tube MaterialsStainless steel / PTFE-lined / specialized polymer (e.g., Delrin®)
DisplayDigital LED interface with programmable speed, time, cycle count, and pause intervals
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ModelThermo 5 / Thermo 10 / Thermo 20 / Thermo 30
MaterialAnodized Aluminum Alloy
Neck Diameter5.6 cm / 5.6 cm / 5.0 cm / 6.4 cm
Static Evaporation Rate0.15 L/day / 0.18 L/day / 0.18 L/day / 0.22 L/day
Hold Time (Full Fill)33.3 days / 55.6 days / 111 days / 145 days
Design StandardISO 23779-compliant cryogenic transfer dewar architecture
ComplianceMeets ASTM F2163 for portable liquid nitrogen containers
Optional AccessoryLockable stainless-steel transport cart with pneumatic casters
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDHS
OriginTianjin, China
ModelNX-3R Pro
Instrument TypeBenchtop Centrifuge
CategoryHigh-Speed Refrigerated Centrifuge (10,000–30,000 rpm)
Maximum Speed21,000 rpm
Maximum RCF33,500 × g
Maximum Capacity4 × 250 mL
Minimum Temperature–20 °C
Dimensions (W × D × H)325 × 470 × 740 mm
Rotor CompatibilityFixed-angle rotors with multiple adapter options
Control Interface7-inch HD color touchscreen
Drive SystemDirect-drive inverter motor
Safety FeaturesElectronic imbalance detection, auto rotor recognition, lid interlock, overspeed/overtemperature protection
Programmability100 user programs, up to 10 segments per program
Acceleration/Deceleration9-step acceleration, 10-step deceleration
ConstructionFull metal housing with corrosion-resistant powder coating
RefrigerationEco-friendly non-CFC compressor system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelAperio VERSA
Application DomainResearch
Technology TypeFluorescence & Brightfield Whole-Slide Imaging
Scanning CapabilityPanoramic + 3D Z-stack
ThroughputHigh-throughput
Operation ModeFully Automated
Form FactorBenchtop
ResolutionHigh-resolution (sub-micron pixel sampling)
Slide Capacity8–200 slides (field-upgradeable)
Motion ControlPositioning accuracy < 0.1 µm (static), dynamic localization precision ≤ ±0.3 µm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer StatusAuthorized Distributor
Product OriginImported
ModelKingFisher Flex
Instrument TypeMagnetic Bead-Based Purification System
Automation LevelDedicated Fully Automatic
Throughput96 samples/batch or 24 samples/batch
Sample Volume Range20–1000 µL (standard) / 200–5000 µL (high-volume)
Processing Time per Batch15–45 minutes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ModelLS-I72 / LS-I201
Temperature RangeAmbient +5 °C to 60 °C
Temperature Uniformity±0.1 °C (at 37 °C setpoint)
Temperature Fluctuation±0.5 °C
Capacity72 L / 201 L
Internal Dimensions (W×D×H)41.5×41.5×41.5 cm / 58.0×58.0×60.0 cm
External Dimensions (W×D×H)52.5×51.5×75.0 cm / 69.0×68.0×95.5 cm
Power Consumption0.4 kW / 0.6 kW
Weight35 kg / 47 kg
Electrical Supply1.2 A / 2 A
Control SystemPID-based digital temperature controller with LED display
Interior MaterialStainless steel (AISI 304)
Door Opening Angle180°
Air CirculationNatural convection
Safety FeaturesIndependent over-temperature protection, short-circuit protection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDHS
OriginTianjin, China
ModelHW-Mixer
Instrument TypeHeated Orbital Shaking Water Bath
Temperature ControlHeating-Only (No Cooling)
Circulation ModeInternal Recirculation
Construction316L Stainless Steel Exterior
Control InterfaceIndustrial Touchscreen Display
Sample PlatformLarge-Scale Orbital Shaking Tray with Customizable Inserts/Supports
Maximum Orbital Diameter50 mm
Application EnvironmentSuitable for Cleanroom-Class Laboratories (ISO Class 5–8 Compatible)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ModelHERAcell 150i
Temperature Range & Accuracy3–55 °C
Temperature Uniformity±0.5 °C
Humidity Control>99.5% RH (non-condensing)
Chamber Capacity150 L
Sterilization MethodContraCon 90 °C moist-heat
CO₂ Sensing OptionsThermal Conductivity (TC) or Dual-Beam Infrared (IR)
Optional O₂ Control Range1–21% or 5–90%
Interior MaterialElectropolished stainless steel (optional 100% pure copper)
Door ConfigurationTriple-pane tempered glass inner doors (3-door configuration for 150 L)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginFinland
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelKingFisher Duo Prime
Instrument TypeMagnetic Bead-Based Purification
Automation LevelSemi-Automated Assistant
Max Samples per Run12 (with 12-channel head) or 6 (with 6-channel head)
Sample Volume Range50–1000 µL in 96-well Deep-Well (DW) plates
Processing Time per Run15–40 minutes
Heating Range10–75 °C (for A-column of deep-well plate, ambient-based)
Cooling Capability4 °C (elution strip only)
Memory Capacity200 pre-loaded protocols
Data TransferUSB drive or PC via BindIt software
DisplayColor LCD touchscreen
UV Lamp8 W, programmable up to 16 hours
Weight17 kg
Language Support8 languages including English, Chinese, Japanese, Russian, German, French, Spanish, and Portuguese
Magnetic Bead Recovery Rate>95%
Compatible ConsumablesKF 96DW Plate (Cat. No. 95040450), KF 24DW Plate (Cat. No. 95040470), Elution Strip for 12-channel head (Cat. No. 97003520)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelHeratherm
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Distributor TypeAuthorized Distributor
Import StatusImported
ModelSPECTRONIC 200
Instrument ArchitectureSingle-beam
Detector TypePhotodiode Array
Wavelength Range340 nm – 1000 nm
Wavelength ScanningAutomatic
Spectral Bandwidth< 4 nm
Wavelength Accuracy±2.0 nm
Stray Light< 0.2 %T
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelRM2245
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Scientific
ModelTSX70086V
OriginUSA
TypeImported ULT Freezer
Effective Storage CapacityUp to 700 × 2-inch cryoboxes
Interior Dimensions (W×D×H, mm)1301 × 1016 × 719
Exterior Dimensions (W×D×H, mm)1981 × 1148 × 955
Power Supply230 V, 50 Hz
Rated Input Power50 Hz
ComplianceDesigned for GLP/GMP environments, compatible with FDA 21 CFR Part 11–enabled software systems
Cooling TechnologyPatented V-Drive™ variable-speed compressor system
Temperature Range–80 °C standard operating range
Temperature Uniformity±1.5 °C (at –80 °C, 24-hr stability, 3-point validation per ISO 14644-1 Class 5 cleanroom-equivalent air management)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelVT1200 S
Maximum Sample Size33 × 40 mm
Section Thickness Range0–20,000 µm
Sectioning Increment1 µm
CategoryVibrating Microtome for Fresh & Fixed Tissue
Added to wishlistRemoved from wishlist 0
Add to compare
OriginSouth Korea
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelJ-Series
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica Biosystems
OriginGermany
ModelBond-III
Automation LevelFully Automated
Staining MethodImmersion-Based
Max. Slides per Run30
Max. Reagent Slots36
Dimensions (W×H×D)790 × 1378 × 806 mm
Primary ApplicationsImmunohistochemistry (IHC), In Situ Hybridization (ISH)
Regulatory ComplianceCE-IVD, FDA-cleared for IVD use in the US
Software PlatformBond RX™ Control Software v5.x
ConnectivityEthernet, DICOM-SR export capable
Power Supply230 V AC, 50/60 Hz, 16 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDHS
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelDHS Quad-Cell Factory System
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelNanoAssemblr Spark
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelCM3050 S
Cutting Temperature Range–35 °C to –15 °C (adjustable)
Section Thickness Range0.5 µm to 100 µm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDHS
OriginBeijing, China
ModelMPC2000
Instrument TypeBenchtop Centrifuge
Speed RangeUp to 4500 rpm
Max RCF2860 × g
Capacity6 × 96-well plates (e.g., PCR, ELISA, deep-well plates)
Alternate Configurations2 × deep-well/PCR plates or 8 × 15 mL conical/tube centrifuge tubes
Rotor OptionsH-type plate rotor (max height 55 mm), 8-position horizontal tube rotor, and optional 96×0.2 mL PCR plate adapter kit
Drive SystemBrushless DC motor, direct drive
SafetyElectronic lid lock with interlock
Operation ModesInstant spin (short-run), timed run
ConstructionAll-metal housing, stainless-steel chamber
Dimensions (W×D×H)288 × 384 × 480 mm
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelVT1000 S
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelSmartCART
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDHS
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
Model No.0401318
Instrument TypeBenchtop Centrifuge
Speed Range300–21,000 rpm
Max. RCF33,500 × g
Max. Capacity4 × 1000 mL
Temperature Range−20 °C to +40 °C
Acceleration/Deceleration Steps9-step acceleration, 10-step deceleration
Rotor RecognitionAutomatic
Programmable StepsUp to 10 segments per program
Total Programs Stored100
Display10-inch full-color capacitive touchscreen
Drive SystemBrushless frequency-controlled motor
Power Supply220 V / 50 Hz
Rated Power3000 W
Dimensions (W×H×D)855 × 395 × 730 mm
Net Weight120 kg
ComplianceCE, ISO 13485 (manufacturing), IEC 61010-2-020
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0