- All
- Favorite
- Popular
- Most rated
| Brand | VITLAB |
|---|---|
| Origin | Germany |
| Material | Polytetrafluoroethylene (PTFE)-coated |
| Type | Cylindrical Magnetic Stir Bar |
| Packaging | Individual units per pack |
| Compliance | ISO 9001-manufactured, USP Class VI compliant PTFE coating |
| Brand | VITLAB |
|---|---|
| Origin | Germany |
| Model | Continuous E / RS |
| Minimum Display | 0.01 mL |
| Accuracy | ≤ ±0.2% (at 25 mL for 1620506 |
| Coefficient of Variation | ≤ 0.1% |
| Dispense per Full Revolution | 2.5 mL (1620506) / 5.0 mL (1620507) |
| Sterilizable | Yes (autoclavable after complete cleaning) |
| Material Contact Surface | Borosilicate glass, PTFE, ETFE, PFA, FEP, Pt–Ir alloy |
| Compliance | DIN EN ISO 8655-6, GLP-ready |
| Brand | VITLAB |
|---|---|
| Origin | Germany |
| Material | PTFE-coated |
| Shape | Triangular |
| Available Sizes | 6×12 mm, 8×25 mm, 14×40 mm, 12×50 mm (edge length × total length) |
| Pack Quantity | 3 per pack |
| Compliance | ISO 9001-manufactured, USP Class VI compliant PTFE |
| Brand | BRAND |
|---|---|
| Origin | Germany |
| Model | 704768 |
| Type | Manual Single-Channel Pipette |
| Volume Range | 0.1–1 µL |
| Maximum Capacity | 1 µL |
| Accuracy | ±0.02 µL |
| Sterilization | Autoclavable at 121 °C / 2 bar |
| Display | 4-digit digital |
| Calibration | Easy Calibration™ (tool-free) |
| Ergonomics | Dual-hand volume adjustment, integrated tip ejection, ergonomic finger rests |
| Compliance | CE-marked per IVD Directive 98/79/EC |
| Brand | Systea |
|---|---|
| Origin | Italy |
| Model | Easychem Pro |
| Product Type | Discrete Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 60 positions (standard carousel) / 30 positions (dual-carrousel configuration) |
| Reagent Positions | 30 |
| Cuvette Path Length | 10 mm |
| Light Source | 6 V / 10 W Halogen Lamp with UV-Visible Output |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5300 |
| Pricing | Upon Request |
| Channel Count | 256–100,000 (in multiples of 256) |
| Voltage Range | 0–5.0 V |
| Max Charge Current | 1.5 A or 2.5 A |
| Max Discharge Current | 2.5 A |
| Voltage Accuracy | ±5 mV |
| Current Accuracy | ±2 mA |
| Energy Accuracy | ±0.2 mAh/hour |
| Min Discharge Cutoff Voltage | 2.0 V |
| Max Charge Voltage Limit | 5.0 V |
| Termination Criteria | 16 programmable conditions including time, voltage, current, dV/dt, capacity, coulombic efficiency, and ΔV |
| Data Logging Interval | As low as 1 minute per cell |
| Independent Channel Control | Yes |
| Brand | VITLAB |
|---|---|
| Origin | Germany |
| Model | Simplex2 |
| Type | Manual Bottle Top Dispenser |
| Volume Range | 0.2–100 mL |
| Minimum Graduation | 0.05 mL |
| Accuracy | ±0.5% |
| Precision (Repeatability) | ±0.1% |
| Sterilization | Autoclavable at 121 °C (after thorough cleaning) |
| Materials | PTFE, ETFE, PFA, FEP |
| Compliance | DIN EN ISO 8655-6, GLP-ready |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | AutoChem 1100 |
| Price Range | USD 28,000–70,000 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–900 nm |
| Sample Capacity | 60 or 96 positions |
| Reagent Positions | 27 (Peltier-cooled) |
| Cuvette Path Length | 10 mm |
| Light Source | 12 V / 20 W Halogen Lamp with UV-Visible Output |
| Detection Speed | Up to 200 determinations per hour |
| Injector Precision | ±0.5% (5–1000 µL), Resolution: 0.1 µL |
| Reaction Disc Temperature Control | ±0.1 °C |
| Cuvette Temperature Control | ±0.1 °C |
| Photometric Accuracy | ±1% OD (0–2.5 OD) |
| Linearity | <0.5% deviation |
| Noise | <±0.002 Abs (at 340 nm, 2.5 OD) |
| Detection Modes | Endpoint, Differential, Timed, and Kinetic |
| Data Interface | RS-232 / USB |
| Operating Environment | 15–35 °C, 20–80% RH |
| Power Supply | 220 V AC |
| Brand | VITLAB |
|---|---|
| Origin | Germany |
| Model | Pipeo |
| Type | Single-Channel Electronic Pipette Controller |
| Volume Range | 0.1–100 mL |
| Operation Modes | Gravity Dispense / Active Pump Dispense |
| Control Interface | Dual-button Ergonomic Interface |
| Ordering Code | 1631500 |
| Brand | VITLAB |
|---|---|
| Origin | Germany |
| Model | maneus |
| Pipette Type | Single-Channel Manual Pipette Controller |
| Volume Range | 0.1–100 mL |
| Valve System | Ergonomic Dual-Action Airflow Valve |
| Operation | One-Handed Control |
| Liquid Level Control | Precision Meniscus Adjustment Lever |
| Integrated Hydrophobic Filter | Yes |
| Compliance | ISO 8655-2 (Pipette Controllers), CE Marked |
| Construction | Chemically Resistant Polymer Housing with Soft-Grip Ergonomic Design |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q5000IR, Q500, Q50 |
| Pricing | Upon Request |
| Brand | VITLAB |
|---|---|
| Origin | Germany |
| Model | MP-1000 |
| Volume Range | 100–1000 µL |
| Accuracy (±%) | ≤0.6% |
| Accuracy (±µL) | ≤0.6 µL |
| CV (±%) | ≤0.2% |
| CV (±µL) | ≤0.2 µL |
| Tip Compatibility | Standard conical universal pipette tips (ISO 8655-compliant) |
| Sterilization | Autoclavable at 121°C, 2 bar (DIN EN 285) |
| Calibration | TD/EX certified per DIN EN ISO 8655-2 |
| Regulatory Compliance | CE-marked per IVD Directive 98/79/EC |
| Qualification | Conforms to DIN 12600 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8500 Series |
| Quotation | Upon Request |
| Voltage Range | Up to 1000 V |
| Current Range | Up to 1000 A |
| Minimum Step Time & Data Acquisition Interval | 50 ms (standard), optional sub-50 ms capability |
| Operating Modes | Galvanostatic (CC), Potentiostatic (CV), Power Control (CP), Resistance Control (CR), and hybrid step sequencing |
| Regenerative Energy Recovery | Grid-to-Battery (G2B) and Battery-to-Grid (B2G) bidirectional architecture |
| Software Platform | MACCOR Test Executive v7.x or later |
| Brand | VITLAB |
|---|---|
| Origin | Germany |
| Model | Genius |
| Type | Electronic Bottle Top Dispenser |
| Volume Range | 0.2–100 mL |
| Minimum Increment | 0.05–2.00 mL (model-dependent) |
| Accuracy | ±0.5% |
| Precision (Repeatability) | ±0.1% |
| Sterilization | Autoclavable at 121 °C (after thorough cleaning) |
| Compliance | DIN EN ISO 8655-6, GLP-ready |
| Brand | VITLAB |
|---|---|
| Origin | Germany |
| Model | Piccolo1 & Piccolo2 |
| Type | Manual Fixed-Volume Bottle Top Dispenser |
| Compatibility | GL28 Thread |
| Materials | PTFE, FEP, Borosilicate Glass, Platinum-Iridium Alloy |
| Accuracy | ±1.0–3.0% (volume-dependent) |
| Precision (Repeatability) | ±0.2–0.4% |
| Volume Ranges | Piccolo1 — 100–1000 µL |
| Dispensing Mechanism | Positive Displacement via Spring-Loaded Piston |
| Rotatable Delivery Tip | 360° Continuous Rotation |
| Weight | <120 g (lightweight ergonomic design) |
| Brand | PV Measurements |
|---|---|
| Model | IV16 |
| Light Source Class | ABA-Class Solar Simulator (Standard) |
| Illuminated Area | 16 cm × 16 cm |
| Voltage Range | ±2.0 V |
| Current Range | 0–10 A |
| Spectral Match Compliance | ASTM E927-23, IEC 60904-9 Ed. 3 |
| Temporal Stability | < ±1% (A-class), < ±3% (B-class), < ±10% (C-class) |
| Irradiance Uniformity | < ±2% (A-class), < ±3% (B-class), < ±10% (C-class) |
| Standard Test Conditions (STC) | 1000 W/m², AM1.5G spectrum, 25 °C ± 2 °C |
| Software | IV Analysis Suite with GLP-compliant data logging, report generation (PDF/text), and audit-trail-enabled parameter calculation (Voc, Isc, Jsc, Pmax, Vmax, Imax, FF, η) |
| Sample Interface | 4-wire Kelvin connection |
| Optional Upgrades | AAA-class simulator, temperature-controlled vacuum chuck, Rs extraction via attenuated-light sweep, automated database export, reverse-bias leakage testing, conveyor integration |
| Brand | AMETEK Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | ParStat 4000 |
| Current Range | ±4 A (standard), ±20 A (optional) |
| Current Resolution | 1.2 fA (at 40 pA range) |
| Current Accuracy | ±0.5% ±4 pA (40–200 pA), ±0.2% of reading ±0.2% of range (2 nA–20 A) |
| Potential Range | ±10 V |
| Potential Accuracy | ±0.2% of reading ±2 mV |
| Potentiostatic Bandwidth | 3.75 MHz |
| EIS Frequency Range | 10 µHz to 5 MHz |
| Sampling Rate | 1 MS/s (synchronized potential/current/auxiliary), 500 kS/s (3 × 16-bit ADC) |
| Input Impedance | ≥10¹³ Ω |
| Leakage Current | ≤2 pA (at <25°C) |
| CMRR | 60 dB @ 100 kHz |
| Compliance Voltage | ±48 V |
| Rise Time (−1.0 V to +1.0 V) | <100 ns |
| Scan Rate | up to 10 kV/s (10 mV step) |
| iR Compensation | Positive feedback & dynamic iR compensation |
| Operating Temperature | 10–50°C |
| Dimensions (L×W×H) | 515 × 490 × 195 mm |
| Weight | 23 kg |
| Certifications | CE compliant |
| Brand | AMETEK Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | VersaSTAT 3F Electrochemical Workstation |
| Current Range | ±650 mA (standard), ±2 A (internal optional) |
| Current Accuracy | ±0.2% of reading + ±0.2% of range (20 nA to 2 A) |
| Potential Accuracy | ±2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Floating Ground Architecture | Yes (isolated electrode connections and rear-panel interfaces) |
| Data Acquisition | 3 × 16-bit, 500 kS/s |
| Input Impedance | ≥10¹² Ω |
| Leakage Current | ≤5 pA at <25°C |
| CMRR | 60 dB @ 100 kHz (typical) |
| Compliance | CE certified, compatible with GLP/GMP environments requiring audit-trail-capable software (via VersaStudio with optional 21 CFR Part 11 modules) |
| Brand | AMETEK Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | Model 263A Potentiostat/Galvanostat |
| Instrument Type | Benchtop Electrochemical Workstation |
| Current Range | 7 decades, 100 mA to 100 nA |
| Current Resolution | 2 pA (min) |
| Potential Range | ±20 V |
| Compliance Voltage | ±20 V |
| Slew Rate | >1 V/µs |
| Rise Time | <1 µs |
| Input Impedance | >10¹² Ω in parallel with <20 pF |
| Electrometer Input Bias Current | <50 pA at 25°C |
| Minimum Time Resolution | 30 µs |
| Minimum Potential Step | 250 µV |
| Noise | <50 µV rms (typical) |
| EIS Frequency Range | Up to 100 kHz (with optional EIS module) |
| Communication Interfaces | IEEE-488 (GPIB), RS-232C |
| Software | PowerSuite (PowerSINE, PowerCORR, PowerCV, PowerSTEP) |
| Operating Temperature | 0–50 °C |
| Dimensions | 44.5 × 47.0 × 14.0 cm (W×D×H) |
| Weight | 16 kg |
| Brand | AMETEK–Princeton Applied Research |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ParSTAT MC Multi-Channel Electrochemical Workstation |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±2 A (standard) |
| Current Accuracy | 20 nA–2 A: ±0.2% of reading or ±0.2% of range |
| 4 nA | <0.5% ±20 pA |
| Potential Accuracy | ±2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Model | PARSTAT 2273 |
| Instrument Type | Electrochemical Workstation |
| Current Range | 12 decades, 2 A to 40 pA |
| Current Accuracy | <0.4% (full scale, 20 µA–2 A) |
| Potential Accuracy | ±10 V |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±2 A (optional ±20 A) |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Current Resolution | 1.2 fA |
| Input Impedance | >10¹³ Ω |
| Capacitance | <5 pF |
| Slew Rate | >15 V/µs |
| Rise Time | <250 ns |
| Minimum Time Resolution | 20 µs |
| Minimum Potential Step | 2.5 µV |
| Noise | <50 µV RMS (typical) |
| IR Compensation | Positive feedback (2 Ω to 2000 MΩ) |
| Current Interruption | 16-bit DAC |
| Voltage Output Range | ±100 V |
| Power Amplifier Output | ±100 V / ±2 A |
| Bandwidth | >15 MHz (3 dB) |
| Software | PowerSuite (PowerCV, PowerEIS, PowerPULSE, PowerSTEP, PowerCORR, PowerSINE) |
| Interface | USB |
| Operating System | Windows 98/2000/NT/XP/Vista/7 |
| Dimensions | 58 cm W × 47.6 cm D × 22.9 cm H |
| Weight | 31 kg |
| Operating Temperature | 0–50 °C (ideal at 25 °C) |
| Relative Humidity | ≤95% non-condensing |
| Altitude | up to 2000 m |
| Brand | AMETEK-Princeton Applied Research |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VersaSTAT 3 Electrochemical Workstation |
| Current Range | ±650 mA (standard), ±2 A (internal optional) |
| Current Accuracy | ±0.2% of reading or ±0.2% of range |
| Potential Accuracy | ±2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Model | VersaSTAT 4 Electrochemical Workstation |
| Current Range | ±1 A (standard), ±2 A (internal optional) |
| Current Accuracy | <0.5% ±20 pA at 4 nA |
| Potential Accuracy | ±0.2% of reading ±2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | SYSTEA |
|---|---|
| Origin | Italy |
| Model | EASYCHEM PLUS |
| Product Type | Discrete Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 60 positions (18-sample carousel + auxiliary racks) |
| Reagent Positions | 18 |
| Flow Cell Path Length | 10 mm |
| Light Source | 6 V / 10 W Halogen Lamp with UV-Visible Spectral Output |
| Detection Principle | Photometric Colorimetry (Static Reaction in Flow-Through Cuvette) |
| Compliance | Designed for ASTM D129, ISO 6878, ISO 15681, USP <621>, EPA Methods 353.2, 365.2, 4500-NH₃ F, 4500-NO₂⁻ B, 4500-P E, and GLP/GMP-aligned workflows |
Show next
