Empowering Scientific Discovery

Beijing Optec Technology Co., Ltd. – Instrument Sales Department

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelNIRQuest+
Instrument TypeLaboratory & Process-Ready
Optical PrincipleFixed-grating spectrometer with linear array detector (non-scanning)
Wavelength RangesNIRQuest+1.7 (900–1700 nm), NIRQuest+2.2 (900–2200 nm), NIRQuest+2.5 (900–2500 nm)
DetectorInGaAs linear array (TE-cooled)
Optical Resolution (FWHM)1.7–5.0 nm (configurable by slit and grating)
Integration Time1 ms to 65 s
Signal-to-Noise Ratio≥15,000:1 (at full signal, 1 s integration, NIRQuest+2.5)
Dynamic Range>25,000:1 (with 16-bit ADC)
InterfaceUSB 2.0 / USB 3.0 (via optional adapter)
ComplianceCE, RoHS, FCC Class B
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
ModelFlame-NIR+
TypeHandheld NIR Spectrometer
Optical PrincipleGrating-based Scanning
Wavelength Range970–1700 nm
Optical Resolution~10 nm FWHM (25 µm slit)
Signal-to-Noise Ratio6000:1 (full signal)
Dynamic Range6000:1 (single acquisition)
Thermal Drift0.08 nm/°C
Scan Rate~400 Hz
Integration Time1 ms – 45 s
DetectorUncooled InGaAs linear array (128 pixels)
Dimensions89.1 × 63.3 × 31.9 mm (34.4 mm including feet)
Weight265 g
InterfaceMicro-USB
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
ModelNIRQuest
TypeLaboratory Benchtop / Portable Fiber-Optic NIR Spectrometer
Wavelength Range900–1700 nm (standard), up to 2500 nm (optional configurations)
DetectorHamamatsu InGaAs linear array (512 or 256 pixels)
CoolingThermoelectric (TEC), stabilized to ~30 °C below ambient
Optical PlatformCrossed Czerny-Turner
A/D Resolution16-bit USB interface
Integration TimeAs low as 1 ms
Sampling ModesDiffuse reflectance, transmission
Grating OptionsMultiple groove densities for resolution/sensitivity trade-offs
Slit Options10, 25, 50, 100, or 200 µm width or fiber-coupled (no slit)
InterfaceSMA 905 fiber port
Software CompatibilitySpectraSuite (with spectral acquisition, basic preprocessing, and export functions)
ComplianceDesigned for GLP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
ModelNIRQuest+
DetectorInGaAs linear array
Wavelength Range900 nm – 2500 nm
Optical Resolution (FWHM)3.13 nm (typ.), 5.47 nm (typ.), 6.25 nm (typ.)
Slit25 µm
CoolingThermoelectric to –20 °C
Integration Time1 ms – 12 s
Dark Noise6–24 RMS counts (dependent on integration time)
Dynamic Range7.5 × 10⁴ (system)
10,0001 (single acquisition)
SNR>15,000:1 @ 100 ms
>13,0001 @ 1000 ms
Dimensions182 × 110 × 47 mm
Weight1.18 kg (without power supply)
Fiber ConnectorSMA 905
Order-Sorting FilterOF1-RG830 long-pass NIR filter (optional)
Grating OptionsGRATING_#NIR1, GRATING_#NIR2, GRATING_#NIR3
Spectral Configuration OptionsNIRQuest+1.7 (900–1700 nm), NIRQuest+2.2 (900–2200 nm), NIRQuest+2.5 (900–2500 nm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcean Optics
ModelFLAME-NIR
TypePortable NIR Spectrometer
PrincipleFiber-coupled, non-cooled InGaAs detection
Wavelength Range950–1650 nm
Optical Resolution~10 nm FWHM (configuration-dependent)
Scan Rate400 spectra/sec
Integration Time1 ms – 65 s
Sampling Interval1 ms → 65 s
Measurement ModeTransmission
DetectorUncooled 128-pixel InGaAs array (900–1700 nm response)
SNR6000:1 (full signal)
Dynamic Range6000:1
Dimensions89.1 × 63.3 × 34.4 mm (incl. feet)
Weight265 g
InterfaceMicro-USB (plug-and-play)
Software CompatibilityOceanView, OmniDriver, NIR chemometrics suite
Slit OptionsUser-replaceable for resolution/sensitivity tuning
LED IndicatorsPower & acquisition status