- All
- Favorite
- Popular
- Most rated
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NIRQuest+ |
| Instrument Type | Laboratory & Process-Ready |
| Optical Principle | Fixed-grating spectrometer with linear array detector (non-scanning) |
| Wavelength Ranges | NIRQuest+1.7 (900–1700 nm), NIRQuest+2.2 (900–2200 nm), NIRQuest+2.5 (900–2500 nm) |
| Detector | InGaAs linear array (TE-cooled) |
| Optical Resolution (FWHM) | 1.7–5.0 nm (configurable by slit and grating) |
| Integration Time | 1 ms to 65 s |
| Signal-to-Noise Ratio | ≥15,000:1 (at full signal, 1 s integration, NIRQuest+2.5) |
| Dynamic Range | >25,000:1 (with 16-bit ADC) |
| Interface | USB 2.0 / USB 3.0 (via optional adapter) |
| Compliance | CE, RoHS, FCC Class B |
| Brand | Ocean Optics |
|---|---|
| Model | Flame-NIR+ |
| Type | Handheld NIR Spectrometer |
| Optical Principle | Grating-based Scanning |
| Wavelength Range | 970–1700 nm |
| Optical Resolution | ~10 nm FWHM (25 µm slit) |
| Signal-to-Noise Ratio | 6000:1 (full signal) |
| Dynamic Range | 6000:1 (single acquisition) |
| Thermal Drift | 0.08 nm/°C |
| Scan Rate | ~400 Hz |
| Integration Time | 1 ms – 45 s |
| Detector | Uncooled InGaAs linear array (128 pixels) |
| Dimensions | 89.1 × 63.3 × 31.9 mm (34.4 mm including feet) |
| Weight | 265 g |
| Interface | Micro-USB |
| Brand | Ocean Optics |
|---|---|
| Model | NIRQuest |
| Type | Laboratory Benchtop / Portable Fiber-Optic NIR Spectrometer |
| Wavelength Range | 900–1700 nm (standard), up to 2500 nm (optional configurations) |
| Detector | Hamamatsu InGaAs linear array (512 or 256 pixels) |
| Cooling | Thermoelectric (TEC), stabilized to ~30 °C below ambient |
| Optical Platform | Crossed Czerny-Turner |
| A/D Resolution | 16-bit USB interface |
| Integration Time | As low as 1 ms |
| Sampling Modes | Diffuse reflectance, transmission |
| Grating Options | Multiple groove densities for resolution/sensitivity trade-offs |
| Slit Options | 10, 25, 50, 100, or 200 µm width or fiber-coupled (no slit) |
| Interface | SMA 905 fiber port |
| Software Compatibility | SpectraSuite (with spectral acquisition, basic preprocessing, and export functions) |
| Compliance | Designed for GLP-aligned workflows |
| Brand | Ocean Optics |
|---|---|
| Model | NIRQuest+ |
| Detector | InGaAs linear array |
| Wavelength Range | 900 nm – 2500 nm |
| Optical Resolution (FWHM) | 3.13 nm (typ.), 5.47 nm (typ.), 6.25 nm (typ.) |
| Slit | 25 µm |
| Cooling | Thermoelectric to –20 °C |
| Integration Time | 1 ms – 12 s |
| Dark Noise | 6–24 RMS counts (dependent on integration time) |
| Dynamic Range | 7.5 × 10⁴ (system) |
| 10,000 | 1 (single acquisition) |
| SNR | >15,000:1 @ 100 ms |
| >13,000 | 1 @ 1000 ms |
| Dimensions | 182 × 110 × 47 mm |
| Weight | 1.18 kg (without power supply) |
| Fiber Connector | SMA 905 |
| Order-Sorting Filter | OF1-RG830 long-pass NIR filter (optional) |
| Grating Options | GRATING_#NIR1, GRATING_#NIR2, GRATING_#NIR3 |
| Spectral Configuration Options | NIRQuest+1.7 (900–1700 nm), NIRQuest+2.2 (900–2200 nm), NIRQuest+2.5 (900–2500 nm) |
| Brand | Ocean Optics |
|---|---|
| Model | FLAME-NIR |
| Type | Portable NIR Spectrometer |
| Principle | Fiber-coupled, non-cooled InGaAs detection |
| Wavelength Range | 950–1650 nm |
| Optical Resolution | ~10 nm FWHM (configuration-dependent) |
| Scan Rate | 400 spectra/sec |
| Integration Time | 1 ms – 65 s |
| Sampling Interval | 1 ms → 65 s |
| Measurement Mode | Transmission |
| Detector | Uncooled 128-pixel InGaAs array (900–1700 nm response) |
| SNR | 6000:1 (full signal) |
| Dynamic Range | 6000:1 |
| Dimensions | 89.1 × 63.3 × 34.4 mm (incl. feet) |
| Weight | 265 g |
| Interface | Micro-USB (plug-and-play) |
| Software Compatibility | OceanView, OmniDriver, NIR chemometrics suite |
| Slit Options | User-replaceable for resolution/sensitivity tuning |
| LED Indicators | Power & acquisition status |
Show next