- All
- Favorite
- Popular
- Most rated
| Brand | Ocean Optics |
|---|---|
| Origin | Imported |
| Model | Ocean HDX |
| Spectral Range | 200–925 nm |
| Detector | Back-Illuminated Thin CCD |
| Resolution | 0.61–0.72 nm FWHM (with 10 µm slit) |
| Signal-to-Noise Ratio | 400:1 |
| Dynamic Range | 12,000:1 |
| Stray Light | < 0.05% (typical, 3 AU at 600 nm) |
| A/D Conversion | 16-bit |
| Integration Time | 6 ms – 10 s |
| Thermal Stability | ±1 pixel over 0–40 °C |
| f/# | f/4 |
| Onboard Memory | Up to 50,000 spectra |
| I/O | 8 programmable digital I/O lines |
| Communication Interfaces | USB 2.0, Gigabit Ethernet, Wi-Fi 802.11n, SPI, RS-232 |
| Operating Temperature | 0–40 °C |
| Dimensions | 88.9 × 63.5 × 52.4 mm |
| Weight | 400 g |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | NIRQuest+ (NIRQuest+1.7 / NIRQuest+2.2 / NIRQuest+2.5) |
| Spectral Range | 900 nm – 2500 nm |
| Detector | InGaAs linear array |
| Optical Resolution (FWHM) | 3.13 nm (typ.), 5.47 nm (typ.), 6.25 nm (typ.) |
| Integration Time | 1 ms – 12 s |
| Dark Noise | 6–24 RMS counts (dependent on integration time) |
| Signal-to-Noise Ratio | >15,000:1 @ 100 ms |
| >13,000 | 1 @ 1000 ms |
| ≥10,000 | 1 @ 100 ms (multiple configurations) |
| Dynamic Range | 7.5 × 10⁶ (system) |
| 10,000 | 1 (single acquisition) |
| Slit | 25 µm |
| Grating Options | GRATING_#NIR1 / #NIR2 / #NIR3 |
| Order-Sorting Filter | OF1-RG830 long-pass NIR filter (optional) |
| Dimensions | 182 × 110 × 47 mm |
| Weight | 1.18 kg (without power supply) |
| Cooling | Thermoelectrically cooled to –20 °C |
| Fiber Connector | SMA 905 |
| Brand | Ocean Optics |
|---|---|
| Model | QE Pro |
| Detector Type | Back-Illuminated CCD |
| Spectral Range | Configurable from 185–1100 nm |
| Resolution | 18-bit digitization |
| Peak Quantum Efficiency | 90% |
| Signal-to-Noise Ratio | 1000:1 (full well) |
| Dynamic Range | 85,000 (typical, single acquisition) |
| Stray Light | <0.08% at 600 nm |
| Onboard Memory Buffer | Yes |
| Optional Integrated Mechanical Shutter | Yes |
| Interchangeable Slit Options | Yes |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | Ocean SR6 |
| Detector Type | CCD |
| Spectral Range | ~185–1100 nm (configuration-dependent) |
| Optical Resolution (25 µm slit) | 0.50–2.0 nm FWHM (configuration-dependent) |
| Signal-to-Noise Ratio | 3500:1 (on-board averaging mode) |
| Dynamic Range | 12,000:1 (single-scan) |
| Integration Time | 7.2 ms – 5 s |
| Thermal Stability | 0.02 nm/°C |
| Pixel Count | 2048 |
| Interface | USB Type-C, SMA 905, 16-pin Samtec TM, RS-232 |
| Operating Temperature | 0–55 °C |
| Storage Temperature | −30–70 °C |
| Dimensions | 89.0 × 63.5 × 31.3 mm |
| Weight | 275 g |
| Brand | Ocean Optics |
|---|---|
| Model | Maya 2000 |
| Spectral Range | 200–1100 nm |
| Detector Type | Back-illuminated FFT-CCD (Hamamatsu S9840) |
| Quantum Efficiency | Up to 90% @ 250 nm |
| Signal-to-Noise Ratio | 450:1 (full well, 1 s integration) |
| Dynamic Range | 15,000:1 (typical, with 16-bit A/D) |
| Stray Light | <0.05% @ 600 nm |
| Optical Resolution (FWHM) | ~0.035 nm (dependent on grating and slit selection) |
| Integration Time | 5 ms – 20 s |
| A/D Conversion | 16-bit, 500 kHz |
| Pixel Array | 2048 × 14 active pixels |
| Pixel Size | 14 µm × 14 µm |
| Slit Options | 5, 10, 25, 50, 100, 200 µm |
| Grating Options | 14 standard gratings, including HC-1 broadband grating (175–1100 nm) |
| Onboard GPIOs | 10 user-programmable digital I/O lines |
| Interface | USB 2.0 |
| Software | SpectraSuite (Windows/macOS/Linux) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Ocean Optics Ocean HR2 |
| Spectral Range | 190–1150 nm (configurable) |
| Detector Type | CCD |
| Optical Resolution | <1.0 nm FWHM (configuration-dependent) |
| Sensitivity | 380:1 (single-scan @ 10 ms) |
| System Dynamic Range | 2.46 × 10⁸ |
| Brand | Ocean Optics |
|---|---|
| Model | Ocean-FX |
| Spectral Range | 200–1100 nm |
| Optical Resolution (FWHM) | 0.8 nm (with 600 l/mm grating & 5 µm slit) |
| Detector | Hamamatsu S11639 CMOS |
| Slit Options | 5, 10, 50, 100, or 200 µm (SMA 905 or FC connector) |
| Sensitivity | Optimized for 200–1025 nm with 25 µm slit |
| Signal-to-Noise Ratio (single scan) | ~270:1 |
| Dynamic Range (single scan) | ~6400:1 |
| Stray Light | <0.08% at 600 nm |
| Integration Time | 10 µs to 10 s |
| Maximum Scan Rate | 3000 spectra/s (host-dependent) |
| Thermal Drift | 0.11 pixels/°C |
| Onboard Memory | 50,000 spectra with timestamping |
| Connectivity | Gigabit Ethernet, Wi-Fi 802.11ac, USB 3.0 |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Ocean Optics Spectral Measurement Kit |
| Spectral Range | 200–1100 nm (configurable) |
| Detector Type | CCD or CMOS (model-dependent) |
| Optical Resolution | 0.1–10 nm FWHM (configuration-dependent) |
| Sensitivity | 1–5000 photons/count (typical, varies with grating & detector) |
| Signal-to-Noise Ratio | ≥300:1 (full signal, 1s integration) |
| Dynamic Range | >4 × 10⁴ (with auto-ranging) |
| Stray Light | <0.05% at 600 nm (typical, grating-dependent) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | Ocean ST |
| Spectral Range | 185–650 nm (UV-Vis) |
| Optical Resolution | 2.2 nm FWHM (configuration-dependent) |
| Signal-to-Noise Ratio | >250:1 (full well, typical) |
| Dynamic Range | 1000:1 (single-scan) |
| Stray Light | <0.2% at 600 nm |
| Detector | Back-thinned CMOS linear array |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Ocean Optics SR2 |
| Spectral Range | 185–1100 nm (configuration-dependent) |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 0.56–1.71 nm |
| Signal-to-Noise Ratio (SNR) | 380:1 (single acquisition) |
| Dynamic Range | 3400:1 (single acquisition) |
| Integration Time | as low as 10 µs |
| Stray Light | Not specified |
| Slit Options | 5–200 µm |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | Ocean Optics HR4 |
| Spectral Range | 220–1050 nm (configurable) |
| Optical Resolution | 0.13–1.16 nm FWHM (configurable) |
| Signal-to-Noise Ratio | 3000:1 (high-speed averaging mode) |
| Dynamic Range | 1300:1 (single-scan) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Detector Type | CCD |
| Model | Ocean SR4 |
| Spectral Range | 190–1100 nm (configurable) |
| Optical Resolution (25 µm slit) | 1.36–1.65 nm (FWHM) |
| Signal-to-Noise Ratio | 3000:1 (per second, High-Speed Averaging Mode) |
| Dynamic Range | 1370:1 (single scan) |
| Integration Time | 3.8 ms – 10 s |
| Stray Light | 2.3 AU |
| Scan Rate | 74 scans/s |
| Thermal Wavelength Stability | 0.05 pixels/°C |
| A/D Conversion | 16-bit |
| Trigger Modes | External, Internal, Software, Level, Edge |
| Interface | USB-C (USB 2.0 compliant) |
| Dimensions | 88.1 × 63.5 × 31.4 mm |
| Weight | 254 g |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | Ocean Optics HR6 |
| Spectral Range | ~185–1100 nm |
| Optical Resolution (FWHM) | <1.0 nm (with 25 µm slit, configuration-dependent) |
| Signal-to-Noise Ratio | 3500:1 (on-board averaging mode) |
| Dynamic Range | 12,000:1 (single scan) |
| Integration Time | 7.2 ms – 5 s |
| Thermal Stability | 0.02 nm/°C |
| Pixel Count | 2048 |
| Interface | USB Type-C, SMA 905, 16-pin Samtec TM, RS-232 |
| Operating Temperature | 0–55 °C |
| Storage Temperature | −30–70 °C |
| Dimensions | 149 × 106 × 48 mm |
| Weight | 931 g |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HR4Pro |
| Spectral Range | 190 nm – 1100 nm |
| Detector | Linear Silicon CCD Array |
| Optical Resolution (FWHM) | 0.42 nm (typ.), 0.72 nm (typ.), 0.47 nm (typ.), 0.62 nm (typ.), ~0.66 nm (typ.), ~0.9 nm (typ.) |
| Sensitivity | 6 counts per photon (RMS dark noise) |
| Signal-to-Noise Ratio | 250:1 (full signal), 290:1 (full signal), 300:1 (full signal) |
| Dynamic Range | 2000:1 (single acquisition), 2500:1 (single acquisition), 1500:1 (single acquisition) |
| Stray Light | <0.05% at 600 nm, <0.10% at 435 nm |
| Integration Time | 3.8 ms – 10 s |
| Linearity | ±0.5% nonlinearity |
| Thermal Drift | 0.03–0.06 pixels/°C |
| Dimensions | 148.6 mm × 104.8 mm × 45.1 mm |
| Weight | 570 g |
| Interface | USB 2.0 (480 Mbps), RS-232 (2-wire), I²C |
| Slit Options | 5 µm, 10 µm |
| Grating Options | H13, H38, H48, HC1 |
| A/D Resolution | 14-bit |
| Fiber Coupling | SMA 905 |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | FS1100 |
| Spectral Range | 300–1100 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 1.3 nm |
| Signal-to-Noise Ratio | 450:1 |
| Dynamic Range | 8000:1 |
| Stray Light | <0.05% at 600 nm |
| Operating System Compatibility | Android & Windows |
| Display | Low-Power Monochrome E-Ink Screen |
| Power Efficiency | Optimized for extended field deployment |
Show next