Empowering Scientific Discovery

Beijing Oulan Guangshi Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandArtium
OriginUSA
ModelPDI-FPDR
Instrument TypeAerosol Detector
ApplicationAirborne Cloud Microphysics Measurement
Laser SourceDiode-Pumped Solid-State (DPSS)
Optical ConfigurationTransmissive Dual-Beam Interferometric
Particle DiscriminationSpherical Liquid Droplets vs. Ice Crystals
Optional FeatureIntegrated Anti-Icing Heater
Compliance ContextDesigned for FAA Part 25/27-certified research aircraft integration and NASA GRC-validated flight test protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandArtium
OriginUSA
ModelLII 300
Measurement PrincipleLaser-Induced Incandescence (LII)
Measured ParameterSoot Mass Concentration, Primary Particle Diameter, Specific Surface Area
Detection Limit<1.0 ppt (<2 µg/m³)
Upper Range10 ppm (20 g/m³)
Dynamic Range>1,000,000:1
Accuracy±2% of reading
Repeatability±2%
Stability±2%
Response Time<100 ms
Soot Primary Particle Size Range10–100 nm
Specific Surface Area ResolutionDerived from LII signal ratio and calibration traceable to NIST standards
ComplianceDesigned for ASTM D6551, ISO 8573-4, and EPA Method 9-compatible particulate characterization workflows
SoftwareReal-time acquisition with timestamped raw signal, background-subtracted incandescence decay, and dual-wavelength LII ratio processing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandArtium
OriginUSA
ModelPDI-TK
TypeLaboratory Laser Diffraction Particle Analyzer
Dispersion MethodDry & Wet
Measurement Range1–1200 µm
Repeatability<1%
Measurement DurationUnlimited
Laser SourceDiode-Pumped Solid-State (DPSSL) Laser
Wavelength532 nm
Optical Probe Weight2.63 kg (TK1), 2.86 kg (TK2)
IP RatingIP66
CalibrationNIST-Traceable, Single-Calibration-for-Life
Signal ProcessorASA2 Advanced Signal Analyzer
Software PlatformAIMS (Advanced Imaging & Measurement Suite)
Optional AccessoriesAnti-Fog Window Shroud, Integrated Thermostatic Heating Module for Sub-Zero/Freezing Environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandArtium
OriginUSA
ModelDIS
ApplicationDroplet & Particle Size, Morphology, Velocity, and Concentration Measurement
TechnologyParticle Tracking Velocimetry (PTV)
Field of View140 mm × 70 mm (2:1 aspect ratio)
IlluminationUniform, Homogeneous LED Backlighting
RuggedizationShock- and Vibration-Resistant Design
Compliance ContextDesigned for ASTM D6328, ISO 9276-2, and USP <788> particle imaging alignment principles
Software SupportProprietary DIS-Analyzer Suite with timestamped frame capture, binary segmentation, and centroid-based trajectory reconstruction
Added to wishlistRemoved from wishlist 0
Add to compare
BrandArtium
OriginUSA
ModelASA
Dispersion MethodDry & Wet
Instrument TypeLaboratory Laser Particle Size Analyzer
Measurement Range1–1200 µm
Repeatability<1%
Measurement DurationUnlimited
Analog Bandwidth10–160 MHz (standard), upgradable to 10–200 MHz
Max Sampling Rate320 MHz (standard), upgradable to 400 MHz
Signal Processing ArchitectureQuadrature-based Fourier Transform (FT) with Phase Pulse Detection (PPD) and Adaptive Sampling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandArtium
OriginUSA
ModelPDI-X00MD
Measurement PrincipleLaser-based phase Doppler anemometry (PDA) / Phase Doppler Particle Analysis (PDPA)
Velocity Range−100 to +300 m/s
Droplet Size Range0.5–2000 µm
Size Accuracy±0.5 µm
Size Resolution0.5 µm
Velocity Accuracy±1% of reading
Volumetric Flow Rate Accuracy±15%
Signal Processor Bandwidth5–150 MHz
Minimum Transit Time100 ns
Maximum Sampling Rate320 MHz (integrated)
Minimum SNR−6 dB
Max Data Throughput100,000 events/s
Operating SystemsWindows XP/2000, Linux 2.4 kernel
Software ArchitectureClient-server over LAN/internet
Data Export FormatsMATLAB (.mat), Excel (.csv), ASCII
ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLaVision GmbH
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelStrainMaser Components
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMCL Think Nano
OriginUSA
ModelNano-M350
Motion AxesX, Y, Z
Travel Range50 μm (X), 50 μm (Y), 25 μm (Z)
Closed-Loop Resolution0.05 nm (25 μm range), 0.1 nm (50 μm range)
Resonant Frequency1 kHz (X), 700 Hz (Y & Z)
Stiffness1.0 N/μm
Angular Deviation (Roll/Pitch)≤1 μrad
Angular Deviation (Yaw)≤3 μrad
Max Horizontal Load0.5 kg
Max Vertical Load0.2 kg
Body MaterialAluminum/Titanium or Invar
Vacuum CompatibilityHigh Vacuum (Non-Bakeable)
ControllerNano-Drive®
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLaVision GmbH
OriginGermany
ModelFlowMaster® 3D
Measurement Dimensionality2D & 3D planar vector fields
Frame Rate>100 Hz
Velocity Range0–3,000 m/s
Accuracy±1% of measured velocity
Measurement Field Size1 m × 1 m
Optical ConfigurationDual-camera stereoscopic imaging with Scheimpflug-aligned lenses
CalibrationSelf-calibration enabled (target-free, off-field, distortion-corrected)
Software PlatformDaVis® v10+
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLaVision GmbH
OriginGermany
ModelFluidMaster-BOS
TypeImported Optical Measurement Instrument
ApplicationQuantitative 2D/3D density and temperature field imaging in transparent media
ComplianceDesigned for GLP/GMP-aligned research environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEkspla
OriginLithuania
Manufacturer TypeOEM Manufacturer (not distributor)
Product TypeImported
ModelPT200
Core ArchitectureDiode-Pumped Solid-State (DPSS) Pump Laser + Integrated Picosecond Optical Parametric Oscillator (OPO)
Tuning Range690–3400 nm (standard), optional UV extension via SHG
Pulse Duration5 ps (PT257/PT259), 70 ps (PT277)
Repetition Rate1 MHz (PT259), 88 MHz (PT257/PT277)
Peak PowerUp to 5 kW
Beam QualityM² ≤ 1.3 (nearly diffraction-limited)
Linewidth<0.3 cm⁻¹ (FT-limited, PT277)
Output MonitoringOptional integrated wavelength meter
Control InterfaceUSB (standard), RS232 (optional), LabVIEW™ drivers included
ComplianceCE-marked, RoHS-compliant, designed for GLP/GMP-adjacent research environments
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0