| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 869 |
| Thermal Resolution | 160 × 120 pixels |
| Image Resolution | 19,200 IR pixels |
| Spectral Range | 7.5–14 µm |
| NETD | < 0.12 °C |
| Temperature Range | −20 to +280 °C |
| Accuracy | ±2 °C or ±2% of reading |
| Frame Rate | 9 Hz @ 160 × 120 |
| Measurement Principle | Non-contact infrared radiometry |
| Detector Type | Uncooled microbolometer |
| Operating Mode | Handheld, battery-powered |
| Thermal Sensitivity Mode | Auto hot/cold spot tracking |
| Data Export Format | JPEG |
| Software Included | testo IRSoft (PC-based analysis suite) |
| Power Supply | Rechargeable Li-ion battery + AC adapter |
| Interface | USB 2.0 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 885 |
| Measurement Method | Non-contact |
| Detector Type | Uncooled Microbolometer |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 320 × 240 pixels |
| SuperResolution Output | 640 × 480 pixels (via software interpolation) |
| Thermal Sensitivity (NETD) | < 30 mK |
| Temperature Range | –50 °C to +650 °C (extendable to +1200 °C with optional high-temp module) |
| Accuracy | ±2 °C or ±2% of reading (whichever is greater) |
| Frame Rate | 9 Hz / 33 Hz (selectable) |
| Focus | Motorized autofocus, minimum focus distance 10 cm |
| Display | Articulating foldable LCD with ergonomic rotating handle |
| Image Format | JPEG (radiometric) + embedded visible-light image |
| Video Recording | Full radiometric infrared video (MP4) |
| Optional Modules | PTA Process Trend Analysis, Panoramic Image Stitching, QR Code Auto-Tagging, Surface Moisture Risk Imaging, Fever Screening Mode, High-Temp Measurement Kit, Voice Annotation via headset |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 865 |
| Detector Type | Scanning Focal Plane Array |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 160 × 120 pixels |
| Enhanced Resolution (via IR SuperResolution) | 320 × 240 pixels |
| Thermal Sensitivity (NETD) | < 0.12 °C |
| Temperature Range | –20 to +280 °C |
| Accuracy | ±2 °C or ±2% of reading |
| Measurement Method | Non-contact infrared radiometry |
| Frame Rate | 9 Hz @ 160 × 120 |
| Operating Mode | Uncooled microbolometer |
| Wavelength Band | Mid-wave infrared (MWIR) |
| Total Measurement Points | 19,200 per frame |
| Image Export Format | JPEG |
| Software Included | testo IRSoft |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | testo 865 |
| Price | Upon Request |
| Spectral Response | Mid-Wave Infrared (MWIR) |
| Detector Type | Scanning Focal Plane Array (FPA) |
| Application | Temperature Measurement |
| Measurement Method | Non-Contact |
| Detector Cooling | Uncooled |
| Frame Rate | 9 Hz @ 160 × 120 |
| Accuracy | ±2 °C or ±2% of reading (whichever is greater) |
| Temperature Range | −20 °C to +280 °C |
| Infrared Resolution | 160 × 120 pixels |
| Spectral Band | 7.5–14 µm |
| Thermal Sensitivity (NETD) | < 0.12 °C |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | testo 885 |
| Measurement Method | Non-contact |
| Detector Type | Uncooled Microbolometer |
| Spectral Range | 7.5–14 µm |
| IR Resolution | 320 × 240 pixels (76,800 measurement points) |
| SuperResolution Output | 640 × 480 pixels |
| Thermal Sensitivity (NETD) | < 30 mK |
| Temperature Range | –50 °C to +650 °C (extendable to +1200 °C with optional high-temp module) |
| Accuracy | ±2 °C or ±2% of reading |
| Frame Rate | 9 Hz / 33 Hz |
| Operating Temperature | Ambient, uncooled operation |
| Image Format | JPEG with embedded radiometric data |
| Focus | Motorized autofocus, minimum focus distance 10 cm |
| Display | Rotatable fold-out LCD with ergonomic rotating handle |
| Optional Modules | PTA Process Trend Analysis, Full IR Video Recording, Panorama Image Stitching, QR Code-based Asset Tagging, Surface Moisture Risk Imaging, Fever Screening Mode, Interchangeable Lenses, Voice Annotation via Headset, Integrated Visible-light Camera with LED Illumination |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 890 |
| Frame Rate | 33 Hz |
| Temperature Accuracy | ±2 °C or ±2% of reading |
| Temperature Range | −30 to +100 °C |
| Infrared Resolution | 640 × 480 pixels |
| Spectral Range | 7.5–14 µm |
| Thermal Sensitivity (NETD) | < 40 mK at 30 °C |
| Detector Type | Uncooled microbolometer |
| Operating Principle | Passive infrared radiometry based on Planck’s law |
| Image Enhancement | SuperResolution upscaling to 1280 × 960 pixels |
| Focus | Motorized autofocus, minimum focus distance 10 cm |
| Display | Rotating, foldable LCD touchscreen |
| Data Storage | JPEG + embedded radiometric data, SD card (2 GB included) |
| Optional Modules | PTA Process Trend Analysis, IR Video Recording, Panorama Stitching, QR Code Auto-Tagging, High-Temp Extension (up to 1200 °C), Surface Moisture Risk Assessment, Fever Screening Mode |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | testo 869 |
| Thermal Resolution | 160 × 120 pixels |
| IR Pixel Count | 19,200 |
| Spectral Range | 7.5–14 µm |
| Thermal Sensitivity (NETD) | < 0.12 °C |
| Temperature Range | −20 to +280 °C |
| Accuracy | ±2 °C or ±2% of reading |
| Frame Rate | 9 Hz @ 160 × 120 |
| Measurement Principle | Non-contact infrared radiometry |
| Detector Type | Uncooled microbolometer |
| Operating Mode | Handheld, battery-powered |
| Image Format | JPEG |
| Software Included | testo IRSoft |
| Power Supply | Rechargeable Li-ion battery + AC adapter |
| Connectivity | USB 2.0 |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | testo 890 |
| Frame Rate | 33 Hz |
| Temperature Accuracy | ±2 °C or ±2% of reading |
| Temperature Range | −30 to +100 °C |
| Infrared Resolution | 640 × 480 pixels |
| Spectral Range | 7.5–14 µm |
| Thermal Sensitivity (NETD) | < 40 mK at 30 °C |
| Minimum Focus Distance | 0.1 m (with wide-angle lens) |
| Spatial Resolution (IFOV) | 0.11–1.13 mrad (lens-dependent) |
| SuperResolution Output | 1280 × 960 pixels |
| Measurement Method | Non-contact infrared radiometry |
| Detector Type | Uncooled microbolometer |
| Operating Temperature Class | Ambient-uncooled |