Empowering Scientific Discovery

Beijing Shengtian Jiayuan Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
KeyDetection Range: 0–250 ppm
LOD1 ppm
Accuracy±5 ppm (0–50 ppm), ±10% FS (50–250 ppm)
T90 Response Time<15 s
Sensor TypeGSS Semiconductor Gas Sensor
Operating Temp0–50 °C
Operating Humidity30–80% RH (non-condensing)
Power12 VDC, 800 mA
Battery Options9.6 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh)
Dimensions195 × 122 × 54 mm (with probe)
Weight<460 g (with probe and battery)
Enclosure RatingIP20 / NEMA 1
CertificationsUL 2034, BS 7860, FCC Part 15, EN 50082-1:1997, EN 50081-1:1992
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
Model200
PriceUpon Request
Measurement Range (Low)0–1.0 ppm
Measurement Range (Medium)0–25.00 ppm
Measurement Range (Leak Detection)0–50.0 ppm
Accuracy±10% (0–0.10 ppm), <±0.5 ppm (0–10.0 ppm), <±2 ppm (10–50.0 ppm)
Resolution0.001 ppm / 0.01 ppm / 0.1 ppm (per range)
T90 Response Time<60 s (all ranges)
Sensing PrincipleGas-Sensitive Semiconductor (GSS)
Operating Temperature−20°C to +50°C
Operating Humidity5–95% RH (non-condensing)
Power Supply12 VDC, 800 mA
Rechargeable Battery Options9.4 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh)
Enclosure RatingIP20 & NEMA 1
Dimensions (w/ probe)195 × 122 × 54 mm
Weight (w/ probe & battery)<460 g
ComplianceFCC Part 15, EN 50082-1:1997, EN 50081-1:1992
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
Model200
PriceUpon Request
Measurement Range0–10 ppm
LOD0.01 ppm
Accuracy±10% of reading
T90 Response Time<60 s
Sensor TypeGSS Semiconductor Gas Sensor
Operating Temperature−20 °C to +50 °C
Operating Humidity5–95% RH (non-condensing)
CertificationsUL 2034, BS 7860, FCC Part 15, EN 50082-1:1997, EN 50081-1:1992
Power Supply12 VDC, 800 mA
Battery Options9.6 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh)
Enclosure RatingIP20 / NEMA 1
Dimensions (w/ probe)195 × 122 × 54 mm
Weight (w/ probe & battery)<460 g
Probe-to-Host Separation DistanceUp to 14 m
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
Measurement Range0–1000 ppm NH₃
Accuracy±5 ppm (0–100 ppm), ±10% FS (100–1000 ppm)
T90 Response Time<60 s
Sensing PrincipleMetal Oxide Semiconductor (MOS)
Operating Temperature−20°C to +60°C
Operating Humidity5–95% RH (non-condensing)
Power Supply12 VDC, 800 mA
Battery Options9.6 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh)
Enclosure RatingIP20 / NEMA 1
Dimensions (w/ probe)195 × 122 × 54 mm
Weight (w/ probe & battery)<460 g
ComplianceFCC Part 15
EN 50082-11997
EN 50081-11992
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0