- All
- Favorite
- Popular
- Most rated
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | KER-WF |
| Price | Upon Request |
| Maximum Feed Particle Size | ≤13 mm |
| Splitting Ratio | Adjustable (1:2, 1:4, or 1:8) |
| Throughput Capacity | 800–1,200 kg/h |
| Motor | Y90S-6, 0.75 kW |
| Power Supply | Three-phase 380 V AC |
| Weight | 80 kg |
| Dimensions (L×W×H) | 700 × 500 × 800 mm |
| Brand | LND Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Custom-Configurable |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | EBT 721 / 150 / 151 / 8371 / 8372 / 8373 |
| Price | Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Measurement Principle | Metal Oxide Semiconductor (MOS) Sensor |
| Detection Range | 0.000–50.00 ppm (multi-range selectable) |
| Accuracy | ±0.005 ppm (0–0.100 ppm), ±10% (0.100–2.00 ppm), ±15% (2.00–20.00 ppm), ±20% (20.00–50.00 ppm) |
| Resolution | 1 ppb (low-range), 0.01 ppm (mid/high-range) |
| T90 Response Time | <10 s (leak range) to <70 s (ultra-low range) |
| Operating Temp | −5°C to +50°C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Power | 12 VDC, 800 mA |
| Rechargeable Options | 9.4 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh) |
| Enclosure Rating | IP20 / NEMA 1 |
| Dimensions | 195 × 122 × 54 mm (with probe) |
| Weight | <460 g (with probe and battery) |
| Compliance | FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SENHK-208 |
| Pricing | Upon Request |
| Measurement Range | 0–20 mg/L or 0–50 mg/L |
| Accuracy | ≤ ±2% F.S. |
| Resolution | 0.01 mg/L |
| Repeatability | ≤ 1% |
| Stability | ≤ ±1% F.S. / 4 h |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤ 90% RH (non-condensing) |
| Dimensions (L×W×H) | 420 × 190 × 280 mm |
| Power Supply | 198–242 VAC, 50 Hz ±1 Hz |
| Power Consumption | 30 VA |
| Weight | 5 kg |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | BioLite |
| Pricing | Upon Request |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GM |
| Pricing | Available Upon Request |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | KER-1/100A, KER-2/100A, KER-3/100A |
| Feed Capacity | 150 g (per bowl), 2×150 g, or 3×150 g |
| Max Feed Size | ≤20 mm |
| Output Particle Size | 800–200 mesh |
| Processing Time | <2 min (KER-1/100A, KER-2/100A), <3 min (KER-3/100A) |
| Bowl Material | High-Manganese Steel |
| Motor Power | 1.1 kW (KER-1/100A), 1.5 kW (KER-2/100A & KER-3/100A) |
| Voltage | 3-phase 380 V AC |
| Weight | 180–200 kg |
| Dimensions (L×W×H) | 500×500×730 mm |
| Control System | Fully Enclosed Automatic Controller |
| Grinding Mechanism | Impact and Abrasion |
| Operation Mode | Dry or Wet |
| Sealing | Hermetic Bowl Closure & Dust-Tight Enclosure |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GL Bioreactor |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EV Series |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | S005-1 |
| Pricing | Available Upon Request |
| Max. Tube Voltage | 10–100 kV |
| Max. Tube Current | 10–100 µA |
| Max. Output Power | 10 W |
| Focal Spot Size | 0.05 mm |
| X-ray Window Material | Beryllium or Glass |
| Radiation Beam Angle | 20°, 28°, or 30° |
| Operation Mode | Continuous Duty |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model Variants | 6 / 6B / 3G / 3G-232Y / 220 / 1000 |
| Detection Range | 10–1.999×10⁹ ions/cm³ |
| Resolution | 10 ions/cm³ |
| Ion Mobility Ranges | 1.0 / 0.4 / 0.15 cm²/V·s |
| Airflow Velocity | 180–200 cm/s |
| Response Time Constant | ~10–15 s |
| Accuracy | ±10% (ion concentration), ±10% (mobility), ±25% (broad-range models) |
| Operating Humidity | ≤90–99% RH (non-condensing) |
| Operating Temperature | –20 to +60 °C |
| Power Supply | DC 9 V / DC 12 V / AC 220 V |
| Output Impedance | 5×10¹⁰ Ω |
| Data Interface | RS-232 or USB (optional software support) |
| Brand | SenTinain |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | N/A |
| Price | USD 6,850 (FOB Beijing) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Model | CT-3L |
| Pricing | Available Upon Request |
| Cryogen Capacity | 5 kg |
| Minimum Bath Temperature | ≤ −40 °C |
| Temperature Control | Adjustable via PID controller |
| Installation | Benchtop or fume hood compatible |
| Net Weight | 63 kg |
| Dimensions (W×D×H) | 530 mm × 560 mm × 980 mm |
| Power Supply | Single-phase AC 220 V, 50 Hz |
| Maximum Vessel Volume Supported | 3 L (standard borosilicate glass Dewar or jacketed reactor) |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | RoHS II |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Smart SpectroTM |
| Pricing | Available Upon Request |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GX |
| Pricing | Available Upon Request |
| Key | Detection Range: 0–250 ppm |
|---|---|
| LOD | 1 ppm |
| Accuracy | ±5 ppm (0–50 ppm), ±10% FS (50–250 ppm) |
| T90 Response Time | <15 s |
| Sensor Type | GSS Semiconductor Gas Sensor |
| Operating Temp | 0–50 °C |
| Operating Humidity | 30–80% RH (non-condensing) |
| Power | 12 VDC, 800 mA |
| Battery Options | 9.6 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh) |
| Dimensions | 195 × 122 × 54 mm (with probe) |
| Weight | <460 g (with probe and battery) |
| Enclosure Rating | IP20 / NEMA 1 |
| Certifications | UL 2034, BS 7860, FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 480V & 490V |
| Torque Range | 0.071–1.412 N·m |
| Output | ±5 V DC (clockwise/counterclockwise) |
| Accuracy (combined) | ±0.15% FS |
| Nonlinearity | ±0.1% FS |
| Hysteresis | ±0.1% FS |
| Nonrepeatability | ±0.06% FS |
| Rotational Effect on Zero | ±0.05% FS |
| Remote Calibration Accuracy (75°F, NIST-traceable) | ±0.05% FS |
| Temperature Effect (Zero) | ±0.003% FS/°F |
| Temperature Effect (Span) | ±0.003% reading/°F |
| Compensated Temp Range | +75 to +175°F |
| Operating Temp Range | −25 to +185°F |
| Storage Temp Range | −65 to +225°F |
| Bandwidth (High-Freq Output) | DC–500 Hz |
| Bandwidth (Low-Freq Output) | DC–1 Hz |
| Input Power | 10.5–24 VDC @ 85 mA nominal |
| EMI Immunity | Enhanced against IGBT-based ASD noise |
| Max Speed Rating | 25,000 rpm |
| Optional Encoder | Dual-track 512 PPR with line driver |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LT-21A / LT-21B / LT-21C |
| Price | Upon Request |
| Measurement Range | 0.003–64,000 mg/L |
| Detection Limit | <0.003 mg/L (practical LOD < 0.3 mg/L) |
| Repeatability | ±2% RSD |
| Accuracy | ±3% error |
| Correlation Coefficient (r) | >0.999 |
| Wavenumber Range | 2800–3100 cm⁻¹ (corresponding to 3.2–3.5 µm) |
| Wavenumber Accuracy | ±2 cm⁻¹ |
| Wavenumber Reproducibility | ±1 cm⁻¹ |
| CH₂/CH₃/Aromatic Resolution | 3% methyl group resolution |
| Auto Zero & Full-Scale Adjustment | Yes |
| Spectral Storage | Yes |
| Statistical Analysis Module | Yes |
| Dimensions | 55 × 37 × 18 cm |
| Net Weight | 16 kg |
| Operating Environment | 10–30°C, 40–80% RH |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | KERP-250×360 |
| Feed Size | ≤150 mm |
| Discharge Size | <13 mm / <6 mm / <3 mm (adjustable) |
| Capacity | 1,200–1,800 kg/h |
| Weight | 400 kg |
| Dimensions (L×W×H) | 910×1000×1360 mm |
| Motor | Y112M-4, 4 kW |
| Voltage | 3-phase 380 V AC |
| Compliance | GB 474, GB/T 18666 |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model Range | CT7000 / CTS3000 / CTD100 / CTM100 |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | PFP7 / PFP7-C / WBW PLUS / 86LA |
| Measurement Range (PFP7-C) | Na 120–160 mmol/L (linearized), K 0–10.0 mmol/L |
| Detection Limit | Na < 0.2 ppm, K < 0.2 ppm, Li < 0.25 ppm, Ca < 15 ppm, Ba < 30 ppm |
| Repeatability | < 1% CV (20 consecutive samples, 10 ppm Na set to 50) |
| Linearity | Better than ±2% (3 ppm Na/K, 5 ppm Li set to 100) |
| Recorder Output | 1.00 V nominal at reading 100.0 |
| Power Supply | 90–125 V or 190–250 V, 50/60 Hz |
| Air Supply | Oil- and moisture-free, 6 L/min at 1 kg/cm² (14 psi) |
| Fuel Compatibility | Propane, butane, natural gas, LPG |
| Dimensions | 420 × 360 × 300 mm |
| Weight | 8 kg |
| Measurement Principle | Mie Scattering Theory (Full-Range) |
|---|---|
| Particle Size Range | 0.1–450 µm (Lab Mode) |
| Detection Channels | 70 Main + 24 Side Array (Lab), 15 User-Configurable Channels (Online) |
| Laser Source | Semiconductor Diode, 760 nm, 5 mW, >20,000 h Lifetime |
| Sample Flow Rate | 70 mL/min (Online) |
| Operating Temperature | 10–50 °C |
| Max Pressure | 100 psi (0.675 MPa) |
| Power Supply | 85–250 VAC, 50–60 Hz |
| Communication Interface | RS-485 |
| Compliance | ISO 13320, NIST-Traceable Calibration |
| Enclosure Materials | Teflon®, Stainless Steel, Borosilicate Glass, BUNA-N |
| Dimensions (Online Unit) | 320 × 110 × 110 mm |
| Weight (Online Unit) | 3 kg |
Show next