- All
- Favorite
- Popular
- Most rated
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Measurement Principle | Metal Oxide Semiconductor (MOS) Sensor |
| Detection Range | 0.000–50.00 ppm (multi-range selectable) |
| Accuracy | ±0.005 ppm (0–0.100 ppm), ±10% (0.100–2.00 ppm), ±15% (2.00–20.00 ppm), ±20% (20.00–50.00 ppm) |
| Resolution | 1 ppb (low-range), 0.01 ppm (mid/high-range) |
| T90 Response Time | <10 s (leak range) to <70 s (ultra-low range) |
| Operating Temp | −5°C to +50°C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Power | 12 VDC, 800 mA |
| Rechargeable Options | 9.4 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh) |
| Enclosure Rating | IP20 / NEMA 1 |
| Dimensions | 195 × 122 × 54 mm (with probe) |
| Weight | <460 g (with probe and battery) |
| Compliance | FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Key | Detection Range: 0–250 ppm |
|---|---|
| LOD | 1 ppm |
| Accuracy | ±5 ppm (0–50 ppm), ±10% FS (50–250 ppm) |
| T90 Response Time | <15 s |
| Sensor Type | GSS Semiconductor Gas Sensor |
| Operating Temp | 0–50 °C |
| Operating Humidity | 30–80% RH (non-condensing) |
| Power | 12 VDC, 800 mA |
| Battery Options | 9.6 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh) |
| Dimensions | 195 × 122 × 54 mm (with probe) |
| Weight | <460 g (with probe and battery) |
| Enclosure Rating | IP20 / NEMA 1 |
| Certifications | UL 2034, BS 7860, FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | 200 |
| Price | Upon Request |
| Measurement Range (Low) | 0–1.0 ppm |
| Measurement Range (Medium) | 0–25.00 ppm |
| Measurement Range (Leak Detection) | 0–50.0 ppm |
| Accuracy | ±10% (0–0.10 ppm), <±0.5 ppm (0–10.0 ppm), <±2 ppm (10–50.0 ppm) |
| Resolution | 0.001 ppm / 0.01 ppm / 0.1 ppm (per range) |
| T90 Response Time | <60 s (all ranges) |
| Sensing Principle | Gas-Sensitive Semiconductor (GSS) |
| Operating Temperature | −20°C to +50°C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Power Supply | 12 VDC, 800 mA |
| Rechargeable Battery Options | 9.4 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh) |
| Enclosure Rating | IP20 & NEMA 1 |
| Dimensions (w/ probe) | 195 × 122 × 54 mm |
| Weight (w/ probe & battery) | <460 g |
| Compliance | FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | B6/1F, 5090 |
| Price | Upon Request |
| Measurement Range | 0–32 ppm (O₃, aqueous phase, electrode-dependent) |
| Output Signals | Dual 4–20 mA (isolated), Dual SPDT Relays (230 VAC / 2 A), Pulse Frequency Output (48 VDC / 40 mA), Dry-Contact Alarm |
| Control Algorithms | P, PI, PD, PID |
| Enclosure Dimensions | 160 × 160 × 58.5 mm |
| Sensor Power | 12–30 VDC, 15 mA |
| Operating Temperature | 0–50 °C |
| Max Flow Rate | 30 L/hr |
| Pressure Rating | 10 mWS (≈1 bar) |
| Measurement Range | 0–500 ppm (as toluene) |
|---|---|
| Accuracy | ±10 ppm (0–200 ppm), ±10% FS (>200 ppm) |
| T90 Response Time | <60 s |
| Sensor Principle | Metal Oxide Semiconductor (MOS) |
| Operating Temperature | −20 °C to +60 °C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Power Supply | 12 VDC, 800 mA |
| Battery Options | 9.6 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh) |
| Enclosure Rating | IP20 / NEMA 1 |
| Dimensions (w/ probe) | 195 × 122 × 54 mm |
| Weight (w/ probe & battery) | <460 g |
| Compliance | FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | 200 |
| Price | Upon Request |
| Measurement Range | 0–10 ppm |
| LOD | 0.01 ppm |
| Accuracy | ±10% of reading |
| T90 Response Time | <60 s |
| Sensor Type | GSS Semiconductor Gas Sensor |
| Operating Temperature | −20 °C to +50 °C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Certifications | UL 2034, BS 7860, FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Power Supply | 12 VDC, 800 mA |
| Battery Options | 9.6 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh) |
| Enclosure Rating | IP20 / NEMA 1 |
| Dimensions (w/ probe) | 195 × 122 × 54 mm |
| Weight (w/ probe & battery) | <460 g |
| Probe-to-Host Separation Distance | Up to 14 m |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Measurement Range | 0–1000 ppm NH₃ |
| Accuracy | ±5 ppm (0–100 ppm), ±10% FS (100–1000 ppm) |
| T90 Response Time | <60 s |
| Sensing Principle | Metal Oxide Semiconductor (MOS) |
| Operating Temperature | −20°C to +60°C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Power Supply | 12 VDC, 800 mA |
| Battery Options | 9.6 V Ni-Cd (940 mAh) or 9.6 V Ni-MH (2100 mAh) |
| Enclosure Rating | IP20 / NEMA 1 |
| Dimensions (w/ probe) | 195 × 122 × 54 mm |
| Weight (w/ probe & battery) | <460 g |
| Compliance | FCC Part 15 |
| EN 50082-1 | 1997 |
| EN 50081-1 | 1992 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AQM60 |
| Gas Detection Range | O₃ (0–150 ppb, 0–500 ppb), NO₂ (0–200 ppb), CO (0–100 ppm), Non-Methane VOCs (0–25 ppm), Toluene (0–500 ppm), SO₂ (0–10 ppm), H₂S (0–10 ppm), NH₃ (0–100 ppm), CO₂ (0–2000 ppm, NDIR), Halogenated Hydrocarbons (0–500 ppm) |
| Sampling Pump | Brushless DC motor-driven helical vane |
| Sample Line Material | PFA, PTFE, Kynar |
| Enclosure Rating | IP66 / NEMA 4 |
| Dimensions | 361 × 254 × 165 mm |
| Weight | <10 kg (sensor-integrated unit) |
| Power Supply | 24 VDC, 1 A |
| Communication | RS232 / RS485 (DB9 / M12 connectors) |
| Data Logging Interval | 2 minutes |
| Certifications | FCC Part 15, EN 61000-6-3:2001, EN 61000-6-1:2001, CE, FC |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model Series | YL6-5000EX (RC/DC variants), YL6-6000EX |
| Ionization Energy Options | 8.4 eV, 10.2 eV, 10.6 eV, 11.7 eV |
| Detection Limit | 0.1 ppb (for benzene-equivalent VOCs) |
| Measurement Range | 1–999 ppb |
| Display Units | ppm, ppb, mg/m³ |
| Data Storage Capacity | 20,000 measurement points |
| Certifications | BASEEFA EEx ia IIC T4, CENELEC EN 50020 |
| Intrinsic Safety Compliance | ATEX Directive 2014/34/EU, IECEx Scheme |
| Alarm Functions | STEL (15-min), TWA (8-hr), user-defined thresholds |
| Communication | Infrared (IR) port |
| Weight | < 0.8 kg (typical) |
| Battery Options | Rechargeable Li-ion (RC) or AA alkaline (DC) |
Show next