| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | CU-502 |
| Pricing | Available Upon Request |
| Measurement Principle | AC-modulated Absorption Photometry (Dual-beam Reference LED Architecture) |
| Target Analyte | Cu²⁺ in Acidic Sulfate Electrolytes |
| Measuring Range (Cu) | 0–20 g/L, 0–50 g/L, 0–80 g/L (user-selectable) |
| Measuring Range (CuSO₄) | 0–100 g/L, 0–200 g/L, 0–300 g/L (correlated) |
| Resolution | 0.1 g/L (Cu), 1 g/L (CuSO₄) |
| Repeatability | ±2% FS |
| Response Time | ≤5 s (t₉₀) |
| Operating Temperature | −5 °C to +40 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Power Supply | AC 85–240 V, 50/60 Hz |
| Output Signal | Isolated 4–20 mA DC (HART-compatible loop) |
| Enclosure | IP65-rated front panel, DIN 96×96 mm cutout |
| Dimensions (H×W×D) | 96 × 96 × 163 mm |
| Weight | ~1.3 kg |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | RP-92 |
| Pricing | Upon Request |
| Instrument Type | Online/Field-Deployable |
| Analytical Principle | Cold Vapor Atomic Fluorescence Spectrometry (CV-AFS) |
| Brand | — |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | Ni-502 |
| Pricing | Available Upon Request |
| Measurement Principle | Absorption Photometry (UV-Vis, 540–560 nm) |
| Detection Range | High Range: 0.0–199.9 g/L Ni |
| Low Range | 0.00–19.99 g/L Ni |
| Resolution | 0.1 g/L (high), 0.01 g/L (low) |
| Accuracy | ±2% FS |
| Operating Temp. | 0–40 °C, ≤85% RH |
| Output | Isolated 4–20 mA DC (3-range switchable: 0–50/100/200 g/L or 0–5/10/20 g/L) |
| Relay Outputs | Two SPDT dry contacts (AC 200 V, 1 A resistive load) |
| Power Supply | AC 85–240 V, 50/60 Hz |
| Enclosure | IP65-rated panel-mount housing (96 × 96 × 163 mm, ~1.3 kg) |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PMT-2500 |
| Pricing | Available Upon Request |
| Detection Principle | Laser Light Scattering (90° scattering geometry) |
| Alarm Indicator | Tri-color LED (Green/Yellow/Red) with stepwise activation based on PM2.5 concentration thresholds |
| Power Supply | 3× AA alkaline batteries (internal) or DC 5 V via included USB cable |
| Display | 4-digit 7-segment LED |
| Accuracy | ±15 µg/m³ (for concentrations <100 µg/m³), ±15% (for ≥100 µg/m³) |
| Response Time | ≤6 seconds (T90) |
| Operating Temperature | −10 °C to +50 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Power Consumption | 0.6 W (active), 0.1 W (standby) |
| Data Logging | User-selectable intervals (1/5/10/30/60 min) |
| Dimensions | 81(W) × 40(H) × 141(D) mm |
| Weight | ≈345 g (including batteries and silicone rubber cover) |
| Accessories | USB cable (15 cm), AA batteries, protective silicone cover |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (PRC) |
| Model | LQ-5Z |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RC-V2 |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CHL-5Z |
| Price | Upon Request |
| Measurement Range | 0.0–200 µg/L (fluorescence-intensity calibrated) |
| Resolution | 0.1 µg/L |
| Display | 3.5-digit LCD |
| Excitation Wavelength | 400–470 nm |
| Emission Wavelength | 600–700 nm |
| Repeatability | ±2% (under controlled conditions) |
| Operating Temperature | 5–35 °C (non-freezing, shielded from direct sunlight) |
| Protection Rating | IP63-equivalent |
| Power Supply | DC 4.5 V (3 × AAA/LR03 batteries) |
| Auto Power-Off | After 30 minutes of inactivity |
| Dimensions | 75 mm (W) × 38 mm (H) × 180 mm (D) |
| Weight | ~300 g |
| Standard Accessories | Instrument body, alkaline batteries, instruction manual, warranty card, carrying case |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | RA-915J |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Online FTIR Spectrometer |
| Interferometer Design | Patented "Double Cat’s Eye" Alignment System |
| Detector | High-Sensitivity Sealed DLATGS |
| Spectral Resolution | Standard ≤ 4 cm⁻¹ (configurable to ≤ 0.5 cm⁻¹) |
| Wavenumber Range | 4000–400 cm⁻¹ |
| Signal-to-Noise Ratio | ≥ 30,000:1 (at 4 cm⁻¹, 1 min scan) |
| Environmental Protection | Integrated Desiccant Monitoring & Auto-Alert for Optical Chamber Humidity |
| Software Compliance | GLP-Ready, FDA 21 CFR Part 11–Compliant Audit Trail & Electronic Signature Support |
| Sample Compartment | Extra-Large Bore (≥ 180 mm Ø), Compatible with Pike Technologies ATR, DRIFTS, Gas Cells, Liquid Cells, and Microscope Modules |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | Light 915 |
| Instrument Type | Portable |
| Detection Principle | Zeeman Atomic Absorption Spectroscopy with High-Frequency Modulated Polarized Light (ZAAS-HFM) |
| Wavelength | 254 nm |
| Detection Limit | <0.1 µg/m³ |
| Operating Duration | Up to 12 h on rechargeable battery |
| Dynamic Range | 5 orders of magnitude |
| Data Storage | Internal memory with USB and Bluetooth export |
| Regulatory Status | Listed on U.S. EPA Emergency Response Equipment List |
| Compliance | Designed for compliance with OSHA PEL, ACGIH TLV, and ISO 6879 for elemental mercury vapor monitoring |
| Brand | Atomtex |
|---|---|
| Model | AT2140 / AT2140A |
| Type | Personal Dose Rate & Dose Meter (γ-ray) |
| Dose Rate Range (AT2140) | 0.01 μSv/h – 10 mSv/h |
| Dose Rate Range (AT2140A) | 0.01 μSv/h – 100 mSv/h |
| Dose Range | 0.01 μSv – 9.99 Sv |
| Dose Measurement Range | 0.1 μSv – 1.99 Sv |
| Relative Measurement Error | ±15% max. |
| Calibration Accuracy | ±5% max. |
| Sensitivity to ¹³⁷Cs | 1.8 cps/(μSv·h⁻¹) |
| Energy Response Range | 50 keV – 3 MeV |
| Energy Dependence (vs. 662 keV ¹³⁷Cs) | ±30% (AT2140), ±25% (AT2140A) |
| Angular Dependence (±60°, ¹³⁷Cs/⁶⁰Co) | ±25% |
| (²⁴¹Am) | ±60% |
| Response Time (Dose Rate >1 � | Sv/h): ≤10 s (AT2140), ≤5 s (AT2140A) |
| Operating Temperature | −20°C to +50°C (AT2140), −30°C to +60°C (AT2140A) |
| Relative Humidity (non-condensing) | ≤95% at 35°C |
| IP Rating | IP40 |
| Drop Resistance | 1.0 m onto hard surface |
| Power Supply | 2 × AA batteries |
| Battery Life | 5,000 h (AT2140), 10,000 h (AT2140A) |
| Dimensions & Weight | 111 × 70 × 28 mm, 0.11 kg |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JP-2D |
| Price | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Capel-205 |
| Pricing | Upon Request |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region | Domestic (China) |
| Model | OLM30B |
| Pricing | Available Upon Request |
| Flow Resolution | 0.01 L/min |
| Repeatability | ±1% FS |
| Maximum Flow Rate | 0–2 L/min |
| Power Supply | 110/220 V AC, 50/60 Hz |
| Power Consumption | 500 W |
| Operating Temperature Range | –10 °C to +50 °C |
| Weight | Air Pump Unit — 6.8 kg |
| Compliance | EPA Method 30B |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Fluorat-02-5M |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SDW-300S / SDW-600W / SDW-120F |
| Price | Upon Request |
| Weighing Accuracy | 0.01 g / 0.005 g / 0.005 g / 0.001 g |
| Max Capacity | 300 g / 300 g / 600 g / 120 g |
| Density Resolution | 0.001 g/cm³ / 0.001 g/cm³ / 0.001 g/cm³ / 0.0001 g/cm³ |
| Measurement Principle | Archimedean buoyancy method (hydrostatic weighing) |
| Sample Types | Solids, granules, foams, floating materials, porous bodies, thin films, and water-absorbing specimens |
| Measurement Time | ~10 seconds |
| Interface | RS-232 serial output |
| Compliance Standards | ASTM D792, ASTM D297, ISO 1183, ISO 2781, GB/T 1033, GB/T 2951, GB/T 3850, GB/T 533, JIS K6268, HG4-1468 |
| Brand | — |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | P-51 |
| Pricing | Upon Request |
| Detection Principle | Colorimetric Gas Detection Tube Method |
| Compliance | Designed to meet CDC-recommended field screening protocols for emergency response and occupational health assessments |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LQ-5Z-Multi |
| Pricing | Available Upon Request |
| Measurement Principle | Electrode-Based (Grab Sampling) |
| Measurement Range | TMAH: 0.00–5.0% / 0.0–50.0 g/L |
| NaOH | 0.00–3.00% / 0.0–30.0 g/L |
| Na₂CO₃ | 0.0–10.0% / 0–100 g/L |
| NH₃ | 0.0–2.00% / 0.0–20.0 g/L |
| H₂SO₄ | 0.0–2.00% / 0.0–20.0 g/L |
| HNO₃ | 0.0–2.00% / 0.0–20.0 g/L |
| Sample Temperature | 0.0–40.0 °C |
| Accuracy | ±5% FS |
| Calibration | Zero and Span Calibration |
| Temperature Compensation | Automatic |
| Enclosure Rating | IP66 |
| Power Supply | 3×AAA batteries with auto power-off |
| Electrode Type | 4C-type, 1 m standard cable |
| Dimensions (Instrument) | 75(W)×180(D)×38(H) mm |
| Electrode Dimensions | φ17×180(L) mm |
| Weight (Instrument) | ~300 g |
| Weight (Electrode) | ~50 g |
| Standard Kit | Analyzer with batteries, 4C electrode, user manual, certificate of conformity |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CU-5Z |
| Price | Upon Request |
| Measurement Principle | Absorption Photometry |
| Measurement Ranges | 0.000–1.200 mol/L (Cu²⁺ molar concentration) |
| Accuracy | ±2% FS (under specified calibration and environmental conditions) |
| Resolution | 0.001 mol/L |
| Calibration | Two-point calibration using certified Cu²⁺ standard solutions |
| Temperature Compensation | Automatic (NTC sensor integrated in CUD-61 electrode) |
| Display | 3½-digit LCD |
| Operating Environment | −5°C to +45°C, ≤85% RH (non-condensing) |
| Power Supply | DC 4.5 V (3 × AA alkaline batteries), auto-power-off after 30 min idle |
| Dimensions (main unit) | 75(W) × 180(D) × 38(H) mm |
| Weight | ~300 g (main unit), ~550 g (CUD-61 electrode with 2 m cable) |
| Standard Configuration | Main unit, CUD-61 copper-selective electrode (2 m coaxial cable), instruction manual, certificate of conformity |
| Brand | AP Buck |
|---|---|
| Model | LP-20 |
| Flow Range | 5–20 L/min (constant-flow mode) |
| Accuracy | ±5% of setpoint (at <5 L/min, with APB-109030 controller) |
| Max Backpressure | 60" H₂O (15 kPa) |
| Power | Rechargeable NiCd battery pack (4.8 V, 1.0 Ah) |
| Operating Temperature | 0–40 °C |
| Dimensions | 11.4 × 10.2 × 5.0 cm (H × W × D) |
| Weight | 879 g |
| Inlet Port | 3/8" OD / 1/4" ID |
| Display | EZ-Backlit™ LCD with multilingual UI (English, Spanish, French) |
| Data Logging | Built-in sampling time, flow rate, and total volume tracking |
| Compliance | Designed for OSHA, NIOSH, and ISO 17025-aligned field sampling workflows |
| Brand | AFRISO |
|---|---|
| Model | E30X |
| Type | Portable Flue Gas Analyzer |
| Sensor Technology | Electrochemical (O₂, CO, NO, NO₂, SO₂, H₂S, etc.) |
| Display | 4.3" TFT Color Screen with Chinese/English UI |
| Data Storage | MicroSD card (up to 16 GB) |
| Battery Life | Up to 12 h (Li-ion, rechargeable during operation) |
| Auto-Calibration | Built-in zero and span check |
| Response Time | <20 s (T90) |
| Accuracy | CO measurement ±2 ppm (low-range), NOₗₒw ≤2 ppm error |
| Compliance | EN 50379-1/-2, DIN EN 15545, CE marked |
| Connectivity | Bluetooth 4.2, USB-C, QR code export |
| Operating Temperature | 0–40 °C |
| Dimensions | 230 × 120 × 65 mm |
| Weight | 1.2 kg |
| Magnetic Mount | Integrated rear magnet for hands-free mounting |
| Brand | AFRISO |
|---|---|
| Origin | Germany (Manufactured under German engineering standards, assembled/quality-controlled in Beijing) |
| Manufacturer Type | OEM/ODM Producer |
| Model | M60X |
| Compliance | EN 50379-1/-2, TÜV-certified |
| Sensor Lifespan | ≥5 years (O₂, CO/H₂, SO₂low, NO, NO₂, NOₓ) |
| Response time (T90) | O₂ <20 s |
| O₂ range | 0–21 vol.% (±0.2 vol.%) |
| CO (H₂-compensated) | 0–20,000 ppm (±5 ppm up to 50 ppm, ±5% of reading above) |
| COhigh | 0–4.0 vol.% (40,000 ppm) |
| SO₂ | 0–5,000 ppm |
| NO | 0–5,000 ppm |
| NO₂ | 0–500 ppm |
| NOₓ (calculated) | 0–5,500 ppm |
| CO₂ (NDIR) | 0–max theoretical (fuel-dependent) |
| Flue gas temperature | 0–1000 °C (±1 °C up to 300 °C, ±1% above) |
| Ambient temperature | −20–+200 °C |
| Differential pressure | ±150 hPa |
| Flow velocity | 0.5–70 m/s |
| Display | 3.5″ TFT color (240 × 320 px) |
| Data logging | Internal + optional microSD/SDHC (up to 32 GB) |
| Battery | Li-ion 3.6 V / 2900 mAh (≥12 h operation, chargeable during measurement) |
| Dimensions | 220 × 90 × 53 mm (incl. magnetic protective sleeve) |
| Weight | ~685 g |
| Enclosure | IP42 (EN 60529) |
| Interface | IR, Bluetooth 4.2, USB Mini-B |
| Accessories | 290 mm 600 °C probe, 2.4 m heated sampling hose, dual-stage KFP condensate filter with integrated thermocouple, ambient temp probe, magnetic sleeve, carry case, charger/USB cable, EN 50379 certificate, factory calibration certificate, user manual |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SDW-4334 |
| Price Range | USD 2,800 – 7,000 |
| Heating Capacity | 4 independent stations (500 W each) |
| Max Operating Temperature | 400 °C |
| Compliance | GB/T 4334–2020 (including optional Method A) |
| Control System | PLC + PID temperature regulation |
| Cooling | Integrated reflux condensation system with auto-recirculation |
| Safety Features | Low-coolant alarm, auto-shutdown, power-interruption resume function |
| Power Supply | 2000 W total |
| Optional Modules | ICT-W closed-loop chiller, ICT-M Wi-Fi remote monitoring, ICT-S SMS-based remote control, ICT-A sensitization test kit, acid fume extraction cabinet |
| Brand | Starwood |
|---|---|
| Model | SDW-160 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Pricing | Upon Request |