| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | JPB-607A |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical (Clark-type Polarographic Probe) |
| Measurement Range | Dissolved Oxygen: (0.0–20.0) mg/L |
| Temperature | (0.0–40.0) °C |
| Accuracy | ±0.30 mg/L (DO), ±0.5 °C (Temperature) |
| Repeatability | ±0.1 mg/L |
| Stability | ±0.10 mg/L over 3 h |
| Response Time | ≤45 s to 90% of final value at 20 °C |
| Zero Oxygen Error | ≤0.10 mg/L |
| Power Supply | Two AA alkaline batteries |
| Display | 3.5-digit LCD with optional blue backlight |
| Calibration | Zero-oxygen and saturated-air (full-scale) calibration supported |
| Temperature Compensation | Automatic, integrated thermistor |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | JPBJ-608 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical (Polarographic Membrane-Type Probe) |
| Range | (0.00–19.99) mg/L DO |
| Accuracy | ±0.30 mg/L |
| Repeatability | ±0.10 mg/L |
| Temperature Range | (0.0–40.0) °C |
| Temp. Accuracy | ±0.5 °C |
| Saturation Range | (0.0–199.9) % |
| Saturation Accuracy | ±10 %FS |
| Zero Error | ≤0.10 mg/L |
| Stability | ±0.10 mg/L / 3 h |
| Response Time (90%) | ≤45 s at 20 °C |
| Data Storage Capacity | 500 sets |
| Protection Rating | IP65 |
| Interface | RS-232 |
| Power Supply | 4 × AA alkaline batteries |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | COD-571 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Rapid Digestion Method (Closed-Tube, Dichromate Oxidation) |
| Measurement Range | 0–1500 mg/L COD |
| Accuracy | ±8% of reading ±1 mg/L (for 0–150 mg/L) |
| Repeatability | ≤3% RSD |
| Digestion Time | 0–120 min (programmable) |
| Batch Capacity | 21 samples per run |
| Digestion Temperature Range | 50–150 °C (control accuracy: ±5 °C below 150 °C) |
| Timing Accuracy | ±5 min at 120 min setting |
| Stability | ±2 mg/L drift over 15 min |
| Operating Environment | 5–40 °C, RH ≤85%, AC 220 V ±10%, 50 Hz ±1 Hz |
| Safety Features | Overtemperature alarm, auto-shutdown post-digestion |
| Data Output | Integrated thermal printer (PP40 type), direct COD concentration readout |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PXSJ-216F |
| Instrument Type | Benchtop |
| Measurement Range | pH (−2.000 to 20.000) |
| Detection Range | 0–19990 (units: µg/L, mg/L, g/L, mol/L, mmol/L) |
| Response Time | 10 s |
| Accuracy | ±0.002 pH/pX |
| Temperature Range | −5.0 to 110.0 °C |
Show next