| Brand | Novalynx |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | WS-16 |
| Instrument Type | Modular Environmental Monitoring System |
| Power Supply | 10–16 VDC |
| Max Current Draw | 60 mA |
| Serial Interface | 9-pin D-Sub (RS-232) |
| Onboard Memory | 128 KB RAM (expandable to 256 KB or 512 KB) |
| Operating Temperature (Data Logger) | –40 °C to +60 °C |
| Clock Accuracy | ±30 seconds/month |
| Wind Speed Range | 0–57 m/s |
| Wind Speed Resolution | >0.1 mph |
| Wind Speed Accuracy | ±1 mph |
| Wind Start Threshold | 0.8 mph |
| Wind Direction Range | 0–360° |
| Wind Direction Accuracy | ±3% |
| Temp. Range (Air) | –40 °F to +140 °F |
| Temp. Accuracy | ±1 °F |
| RH Range | 0–100% RH |
| RH Accuracy | ±3% (10–90% RH) |
| Barometric Pressure Range | 28.25–30.75 inHg (85 hPa span) |
| Pressure Resolution | ±0.01 inHg (±0.3 hPa) |
| Pressure Absolute Accuracy | ±0.05 inHg |
| Rainfall Resolution | 0.01 in/tip |
| Rainfall Accuracy | ±4% up to 3 in/hr |
| Solar Radiation Sensor | Silicon Pyranometer |
| Spectral Range | 0.4–1.1 µm |
| Sensitivity | ~80 mV per 1000 W/m² |
| Radiation Accuracy | ±5% |
| Enclosure Rating | NEMA-4X |
| Default Logging Interval | Configurable (e.g., 15 min) |
| Storage Capacity (6 sensors @ 15-min interval) | 45 days |
| Analog Input Resolution | 12-bit |
| Analog Accuracy | ±0.1% of full scale |
| Alarm Outputs | 2 relay outputs |
| Communication Options | RS-232 standard |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 703 |
| Price | USD 1 (Reference Only) |