Beijing Waterland Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTurner Designs
OriginUSA
ModelC7 oil
Instrument TypePortable
Measurement PrincipleUV Fluorescence Spectrophotometry
Measurement Range0–2700 ppb (crude oil), 0–10,000 ppb (refined oil)
Detection Limit0.2 ppb (crude), 2 ppb (refined)
Accuracy±0.1 ppb
Resolution0.01 ppb
Measurement Frequency1 Hz
LinearityR² ≥ 0.99
Dimensions14.48 × 2.23 cm
Weight160 g
Operating TemperatureAmbient 0–50 °C, Water –2–50 °C
Depth Rating600 m
Output Signal0–5 VDC
Supply Voltage3–15 VDC
Power Consumption<300 mW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTurner Designs
OriginUSA
ModelTrilogy
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleFluorescence Spectrophotometry
Detection Range0–2,000 ppb (crude oil in water, quinine sulfate calibration)
Limit of Detection (LOD)0.2 ppb (crude oil) / 0.25 ppb (refined oil, naphthalene calibration)
AccuracyLinear response across full dynamic range
Resolution0.2 ppb
Operation ModeManual sample introduction and measurement
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTurner Designs
OriginUSA
ModelC7F
Instrument TypeOnline Analyzer
Measurement PrincipleFluorescence Spectrophotometry
Measurement Range0–1,500 ppb (as hydrocarbon)
Detection Limit0.2 ppb
Power Consumption<300 mW
OutputReal-time Analog (4–20 mA or 0–5 V)
Form FactorCompact, Submersible Sensor Module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTurner Designs
OriginUSA
ModelTD500D
Instrument TypePortable
Measurement PrincipleUV Fluorescence Spectrophotometry
Detection Range (Channel A)0.05–50 ppm
Detection Range (Channel B)0–1000 ppm
LOD (Channel A)<50 ppb
LOD (Channel B)<1 ppm
Accuracy±2% of full scale
Repeatability±2% of full scale
Sensitivity<1 ppm for most hydrocarbons
CalibrationSingle-point + blank
Warm-up Time5 s
Response Time5 s
Measurement Time<4 min per sample
Dimensions4.45 × 8.9 × 18.4 cm
Weight0.4 kg
Enclosure MaterialNon-metallic
IP RatingIP67
Operating Temperature5–40 °C
Compatible Solventsn-Hexane, Vertrel XF, AK-225, Xylene, Freon, Horiba solvents
Sample VesselsMicro-cuvettes (API gravity <45) or 8-mm tubes (API gravity >45)
Power Supply4 × AAA batteries (>1000 measurements per set)
Auto-power-offAfter 3 min idle
DisplayLCD with status indicators
AlarmsLow battery, circuit fault, high blank
ComplianceISO 9001:2000, CE-marked
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTurner Designs
OriginUSA
ModelCyclops-7F
Instrument TypePortable
Measurement PrincipleUV-Induced Fluorescence (PAH-Specific)
Measurement Range0–2700 ppb (as naphthalene or equivalent PAH standard)
Detection Limit0.2 ppb
Accuracy±0.01% FS (Full Scale)
Resolution0.2 ppb
Sampling Frequency1 Hz
Housing OptionsTitanium alloy or high-performance polymer (for corrosion/salinity resistance)