Empowering Scientific Discovery

Beijing Waterland Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSolinst
OriginCanada
Model425
Sampling Depth150 m
Sample Volume per Cycle1800 mL
Volume Accuracy±1%
Fill Rate1800 mL/min
Minimum Sampling Interval5 min
Sampler TypeManual, Portable, Discrete-Depth
Sampling MethodPressure-actuated, Hydrostatic-fill
Construction MaterialsStainless Steel Body, Viton O-rings, PTFE Components, LDPE Tubing (standard), Optional FEP-lined PE Tubing
ComplianceASTM D6771, ASTM D7929, ISO 5667-3, US EPA Method 502.2, US EPA Method 8260D (VOCs), GLP-Compatible Operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSolinst
OriginCanada
Model429
Instrument TypePortable Manual Water Sampler
Sampling MethodDiscrete Depth Bailer
Single Sample Volume50–2000 mL
Sampling DepthUnlimited (Depth-Limited Only by Cable Length & Well Geometry)
Construction Material316 Stainless Steel with PTFE Ball Valves and Viton O-Rings
Standard Lengths2 ft (610 mm), 3 ft (910 mm), 4 ft (1220 mm)
Diameter Options0.5 in (12.7 mm), 1.0 in (25.4 mm), 1.5 in (38.1 mm), 2.0 in (50.8 mm)
Sample Release MechanismIntegrated Stainless Steel Controlled-Flow Dispenser
Recommended Support LineSolinst Model 103 Marked Measuring Line
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSolinst
OriginCanada
Model428
Instrument TypePortable Manual Water Bailer Sampler
Sample Volume200–1000 mL
Construction MaterialHDPE (High-Density Polyethylene)
Body TransparencySemi-transparent
Check ValveFixed PVC ball valve
Dimensions (Standard)38 mm Ø × 915 mm L (1.5″ × 36″), total length 965 mm (38″)
Narrow Version Dimensions19 mm Ø × 1016 mm L (3/4″ × 40″), total length 1041 mm (41″)
Release MechanismStandard or optional low-flow release assembly
ComplianceDesigned for ASTM D6771, ASTM D6987, and EPA Method 500.0 field sampling protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSolinst
OriginCanada
Model408
Instrument TypePortable Pneumatic Groundwater Sampler
Sampling Depth150 m
Sampling Flow Rate≤100 mL/min
Valve ActuationCompressed Air-Driven Dual-Valve Mechanism
Construction Materials316 Stainless Steel (42 mm or 16 mm OD) or PVC
Manual Winch CompatibilityYes, with Brake Disc for Depth Locking
Electrical Control OptionCompatible with Solinst Model 464 Electronic Controller
Sample Volume ControlDiscrete, Operator-Initiated
ComplianceDesigned for ASTM D5088, ISO 5667-3, and EPA Method 502.2 field-sampling protocols
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0