- All
- Favorite
- Popular
- Most rated
| Brand | Charm |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Charm II Plus |
| Detection Scope | Antibiotics, Aflatoxins, Pesticides, ATP |
| Automation Level | Semi-Automatic |
| Analysis Time | 10 min per sample |
| Repeatability | ≥99.99% |
| Accuracy | ≥99.99% |
| Regulatory Approvals | NCIMS/FDA (6 certified dairy methods), Codex Alimentarius, MRL-compliant |
| Software Option | CS2 Data Management Suite |
| Sample Types | Raw milk, pasteurized milk, whey, cream, honey, feed, aquaculture samples, poultry tissues |
| Brand | Charm |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | novaLUM |
| Price Range | USD 6,800 – 34,000 (FOB) |
| Detection Principle | Firefly Luciferase–Luciferin Bioluminescence Reaction |
| Read Time | ≤5 s |
| Sensitivity | <1 fmol ATP |
| Storage Capacity | 5,000 test records |
| Sample Points per Plan | Up to 400 |
| Power | Rechargeable Li-ion battery (8–10 h runtime) |
| Weight | <450 g |
| Calibration | Automated on-board calibration |
| Connectivity | USB & Bluetooth to novaLINK Software |
| Keyboard | Full digital keypad |
| Detector | High-gain photomultiplier tube (PMT) |
| Multi-assay Capability | 8 independent assay configurations |
| Compliance | Designed for ISO 22000, HACCP, FDA Food Code, and USDA FSIS sanitation verification protocols |
| Brand | Charm |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | novaLUM II-X |
| Detection Method | Bioluminescence-based Assay for Organophosphates & Carbamates |
| Measurement Scope | Cereals & Oils, Vegetables, Fruits, Dairy Products |
| Intra-instrument Precision | CV ≤ 15% |
| Detection Time | ≤15 min (for target analytes) |
| Sensitivity | 100–1000× higher than conventional enzyme inhibition assays |
| Sample Preparation | Minimal—aqueous samples (e.g., milk, water) require no extraction or purification |
| Reagent Shelf Life | 12 months at 2–8 °C |
| Instrument Power | Rechargeable Li-ion battery (≥9 h continuous operation) |
| Data Interface | USB 2.0 + integrated Wi-Fi module for real-time data transmission and report export |
| Brand | Charm |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LF-ROSA-M |
| Detection Target | Mycotoxins in Milk and Dairy Matrices |
| Automation Level | Semi-Automatic |
| Analysis Time | 3–15 min per sample |
| Repeatability | ≥99.999% |
| Accuracy | ≥99.999% |
| Regulatory Approvals | USDA-GIPSA & FGIS Certified |
| Validation | China National Grain and Oils Quality Inspection Center Verified |
| Brand | Charm |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ROSA M-Reader |
| Price Range | USD 1,400 – 25,000 (FOB) |
| Function Type | Multi-analyte Quantitative Immunoassay Platform |
| Sample Versatility | Cereals, Feed, Nuts, Corn, Wheat, Barley, Soybean Meal, Ground Spices |
| Wavelength Range | Not Applicable (Reflectance-based Optical Detection) |
| Assay Time | ≤5 min per test |
| Repeatability | CV <15% (within-run) |
| Detection Channels | 4 independent optical channels |
| Brand | Charm |
|---|---|
| Model | novaLUM II |
| Origin | Beijing, China |
| Instrument Type | Dairy-Specific Analyzer |
| Automation Level | Semi-Automatic |
| Analysis Time | 45 s per sample (for alkaline phosphatase in pasteurized milk) |
| Repeatability | <0.5% RSD |
| Accuracy | 99.9% |
| Detection Limit | 20 mU/L |
| Interface | Touchscreen |
| Calibration | Fully Automatic |
| Data Storage Capacity | 16,384 test records |
| Compliance | NY/T 3799–2020 (PRC), ISO 22160 / IDF 209, NCIMS-recognized, NZFSA-verified, TDIA-validated, APHA F-AP method |
| Brand | Biotai |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CUKA-IX |
| Price Range | USD 21,000 – 28,000 |
| Grain Types Supported | Wheat, Corn, Paddy Rice, Soybean, Peanut, Sunflower Seed |
| Detection Targets | Insect-Damaged Kernels, Diseased Kernels (Black Germ, Gibberella-Damaged), Broken Kernels, Sprouted Kernels, Moldy Kernels, Heat-Damaged Kernels |
| Imaging System | Conveyor-Based Linear High-Resolution Scan |
| Spatial Resolution | 0.024 mm |
| Throughput | Full Sample Analysis in ≤120 s |
| User Interface | Capacitive Touchscreen with Onboard Data Storage |
| Automation | Auto-Start on Feed Detection, Auto-Stop Post-Analysis |
| Traceability | Full Audit Trail of Operator Actions and Measurement Events |
| Compliance Framework | Designed to Support ISO 712, ISO 6540, GB/T 5494–2019, and AACCI Method 47–01 workflows |
| Brand | Charm |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EZ |
| Price Range | USD 7,000 – 28,000 |
| Brand | Charm |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | LF-ROSA-EZ |
| Price Range | USD 14,000–28,000 |
| Detection Targets | β-Lactams, Sulfonamides, Quinolones, Tetracyclines, Lincosamides, Macrolides, Streptomycins, Aminoglycosides, Phenicol-class antibiotics, β-Lactamase, Aflatoxin M1 |
| Automation Level | Semi-Automatic |
| Analysis Time | 1–8 minutes per sample |
| Repeatability | ≤ ±5% CV (typical across validated ROSA test strips) |
| Accuracy | Meets AOAC Performance Tested Method (PTM) and EU Commission Regulation (EU) No 519/2014 criteria for screening assays |
| Brand | BioControl |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Assurance GDS |
| Pricing | Available Upon Request |
| Brand | Charm |
|---|---|
| Origin | USA |
| Model | CHARM II 7600 |
| Function Type | Multi-analyte Screening Platform |
| Sample Applicability | Universal for Food & Agricultural Commodities |
| Wavelength Range | 300–680 nm |
| Assay Time | ≤10 min per test |
| Repeatability | ≤0.5% CV |
| Detection Channels | Dual-channel optical reader |
| Regulatory Recognition | FDA-accepted, EU-validated, HKFDA & MFDS (Korea) endorsed, GB/T-standardized in China |
| Brand | Biotai |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BOT-HMD |
| Price Range | USD 21,000 – 28,000 (FOB) |
| Power Supply | 220 V AC, 50/60 Hz |
| Brand | Charm |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Charm ROSA |
| Price Range | USD 7,000 – 28,000 |
| Brand | Charm |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EZ-M |
| Price Range | USD 7,000 – 28,000 |
| Brand | AGDIA |
|---|---|
| Origin | USA |
| Model | ISK66800/0025 |
| Format | Lateral Flow Immunoassay (LFIA) |
| Target | ToBRFV coat protein |
| Detection Limit | ≤1 ng/mL in infected leaf or fruit tissue extracts |
| Assay Time | 10–15 minutes |
| Storage | 2–8 °C, desiccated |
| Shelf Life | 18 months from manufacture |
| Regulatory Status | For research and diagnostic use only |
| Brand | AGDIA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XCS66800/0048 |
| Price Range | USD 999–9,999 |
Show next