Empowering Scientific Discovery

Beijing Zhongke Huifen Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhongkehuifen (ZK-HG)
OriginBeijing, China
TypeOil-Free Laboratory Air Generator
Output Flow0–3 L/min
Output Pressure0–0.4 MPa (adjustable)
Air PurityOil-free, Triple-Stage Purification
Noise Level≤30 dB(A)
Power Rating150 W
ProtectionOverpressure, Overcurrent, Overtemperature
ConstructionFully Enclosed Compressor, Vibration-Free Operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTri-Gas Generator System
Nitrogen Purity99.999% (O₂ < 1 ppm)
Hydrogen Purity99.999% (O₂ < 1 ppm)
Air PurityOil-free, Class 1 compressed air per ISO 8573-1:2010
Nitrogen Output Pressure0.4 MPa
Hydrogen Output Pressure0.3 MPa
Air Output Pressure0.4 MPa
Nitrogen Flow Rate0–300 mL/min
Hydrogen Flow Rate0–300 mL/min
Air Flow Rate0–2 L/min
Input PowerAC 220 V, 50 Hz
Operating Temperature0–40 °C
Relative Humidity<85% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhongkehuifen
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelH2-300
Output Purity99.99% (v/v, O₂-equivalent)
Flow Rate0–300 mL/min
Input VoltageAC 220 V, 50 Hz
Operating Temperature10–40 °C
Relative Humidity<85% RH
Max Power Consumption210 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelGC-7820
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhongkehuifen
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Model5B-3A
Detection Range20–1500 mg/L COD
Digestion Temperature165 °C ±1.0 °C
Digestion Time10 min
Measurement Time20 min for up to 9 samples
Chloride Interference Tolerance≤1000 mg/L (standard), ≤4000 mg/L (with high-chloride correction)
Repeatability≤0.03% RSD
Optical Stability0.01 A / 5 min
Built-in Calibration Curves20 (user-editable and savable)
Data Storage Capacity1000 records (including parameter ID, timestamp, and value)
DisplayIntegrated LCD
ConnectivityRS232 or USB for data export
PrinterBuilt-in thermal printer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginShanghai, China
ModelAKF-2010
Moisture Range0.001–100% w/w
Resolution1 µg H₂O
Repeatability≥99.7% (at 10 mg water)
Max Error±0.3%
Titration Speed Control0.5 µL–0.1 mL adjustable
Display5.6" TFT LCD (640×480 px)
Data Storage100,000+ records (expandable)
ElectrodeDual-platinum electrode
Valve & Tubing MaterialFEP-coated electromagnetic 3-way valve
Operating Temp5–40 °C
Humidity Limit≤80% RH
Power220 V / 50 Hz / 50 W
Interface OptionsRS-232C, USB, Ethernet (Web-enabled)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelAAS6000
PriceUpon Request
Wavelength Range190–900 nm
Monochromator TypeCzerny-Turner
Spectral Bandwidth0.1 / 0.2 / 0.4 / 0.7 / 1.4 nm (5-step auto-switching)
Grating Blaze Wavelength230 nm
Grating Line Density1800 lines/mm
Wavelength Accuracy±0.25 nm
Wavelength Repeatability<0.10 nm
Optical Resolution<0.3 nm
Characteristic Concentration (Cu)<0.025 µg/mL per 1% absorption
Detection Limit (Cu)<0.006 µg/mL
Precision (Cu)<0.8% RSD
Baseline Stability0.003 Abs (static), 0.004 Abs (dynamic)
Background CorrectionD₂ Lamp + Self-Reversal Method
Atomization SystemTitanium Nebulizer Chamber & Burner Head
NebulizerCustom Wirsching-type Glass Nebulizer
Fuel ControlContinuously Adjustable Acetylene Flow with Real-time Monitoring
Communication InterfaceUSB 2.0
Software InterfaceWindows-based, Bilingual (EN/CN), Fully Automated Qualitative & Quantitative Analysis
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0