BrandZHONGKEHUIFEN
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelGC-7820 LPG Analysis Dedicated Gas Chromatograph
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose with LPG-specific configuration
Temperature Control RangeAmbient + 3°C to 450°C
Oven Ramp Rate0.1–40°C/min
Cooling Rate~8 minutes (450°C → 50°C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature450°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
ModelWLS-08
Detection PrincipleFlame Photometric Detection (FPD)
Temperature Control RangeAmbient +3°C to 400°C
FPD Sulfur Detection Limit≤5×10⁻¹¹ g(S)/s
Column Oven Programmed Ramp0.1–40°C/min, up to 5 steps
Dimensions635 × 490 × 470 mm
Weight~55 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhongkehuifen
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHF-901
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose
Oven Temperature Range4°C to 450°C
Oven Ramp Rate0.1–80°C/min
Oven Cool-down Time~6 min (450°C → 50°C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature450°C
Injector Pressure Setpoint Range0–970 kPa
Injector Total Flow Setpoint Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
ModelGC-2060
Temperature Control RangeAmbient + 3 °C to 450 °C
Oven Ramp Rate0.1–40 °C/min
Cooling Time~8 min (450 °C → 50 °C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Max Operating Temperature450 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
FPD Detection Limit (H₂S)0.02 ppm (v/v)
FPD Detection Limit (Thiophene)0.03 ppm (v/v)
Oven Temperature Stability±0.1 °C
Baseline Noise≤0.1 mV
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhongkehuifen
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelGC-7820
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature RangeAmbient + 3 °C to 450 °C
Oven Ramp Rate0.1–40 °C/min
Oven Cooling Time~8 min (450 °C → 50 °C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
Instrument TypeLaboratory Gas Chromatograph
Application FieldUniversal (Petroleum Refining & Fuel Quality Control)
Oven Temperature RangeAmbient + 5 °C to 450 °C
Maximum Ramp Rate0.1–80 °C/min
Cooling Rate450 °C → 50 °C in ≤6 min
Carrier Gas Flow Range0–1200 mL/min
Carrier Gas Pressure Range0–970 kPa
Injector Max Temp450 °C
Injector Pressure Setpoint Range0–970 kPa
Injector Total Flow Setpoint Range0–1200 mL/min
Power Supply220 V, 50 Hz
Operating Ambient15–35 °C, 5–95% RH
Column Oven Dimensions280 × 300 × 170 mm
Max Run Time999.99 min
Programmable Temperature Steps16
DetectorFID (Hydrogen Flame Ionization)
FID Sensitivity<5 pg C/s (n-hexadecane)
FID Linear Dynamic Range10⁷ (±10%)
FID Data Acquisition Rate20 Hz
Valve OptionsMotorized 4-/6-/10-port valves with electronic pressure/flow control module
Injector TypesPacked-column & split/splitless capillary injectors
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelGC-7820 Fully Automated Coal Mine–Specific Gas Chromatograph
Instrument TypeOnline Gas Chromatograph
Application FieldCoal Mining Industry
Temperature Control RangeAmbient + 3 °C to 450 °C
Oven Ramp Rate0.1–40 °C/min
Cooling Rate~8 min (450 °C → 50 °C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
ModelHF-901D
Temperature Control RangeAmbient + 3°C to 450°C
Ramp Rate0.1–40°C/min
Cooling Time~8 min (450°C → 50°C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Max Temp450°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Detection GasesH₂, CH₄, C₂H₄, C₂H₆, C₂H₂, CO, CO₂
Minimum Detectable Concentration in Oil≤1 µL/L (for all target gases)
Analysis Cycle Time≤7 min
Temperature Stability±0.1°C
Power Consumption1.9 kW
Dimensions (W×D×H)660 × 560 × 480 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
ModelZX-2000
Instrument TypeOnline Gas Chromatograph
Application FieldHigh-Purity Gas Analysis
Oven Temperature RangeAmbient + 3°C to 450°C
Ramp Rate0.1–40°C/min
Cool-down Time~8 min (450°C → 50°C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature450°C
Injector Pressure Setpoint Range0–970 kPa
Injector Total Flow Setpoint Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhongkehuifen
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelZX-3000
Instrument TypeOnline Gas Chromatograph
ApplicationHigh-Purity Gas Analysis
TCD Sensitivity≥4000 mV·mL/mg (benzene)
Repeatability≤1% RSD
Linearity Error≤±1.5% mV/h
Temperature ControlNot Specified
Flow/Pressure ControlNot Specified
Injector Max Temp/RangeNot Specified
Cooling/Heating RatesNot Specified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
ModelGC-2060
Instrument TypeLaboratory Gas Chromatograph
Application FieldPetrochemical Industry-Specific
Temperature Control RangeAmbient + 3°C to 450°C
Oven Ramp Rate0.1–40°C/min
Cool-down Time~8 min (450°C → 50°C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature450°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelHF-901 Gasoline PONA Analysis
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose Hydrocarbon Group-Type Analysis
Oven Temperature RangeAmbient + 3 °C to 450 °C
Oven Ramp Rate0.1–40 °C/min
Oven Cool-Down Time~8 min (450 °C → 50 °C)
Carrier Gas Flow Range & Control0–1200 mL/min (EPC)
Carrier Gas Pressure Range & Control0–970 kPa (EPC)
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–970 kPa (EPC)
Injector Total Flow Setting Range0–1200 mL/min (EPC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
ModelGC-6890A Mine-Specific Gas Chromatograph
Instrument TypeLaboratory Gas Chromatograph
Application DomainCoal Mining Industry
Detection ConfigurationTCD + Dual FID + Methane Converter
Sample IntroductionAutomated 10-Port Valve with Manual/Ball-Bag Sampling Option
Column SystemDedicated Packed Columns with Triple Pre-cut Traps
Analysis Time4–8 min per injection
Minimum Detectable ConcentrationCO & C₂H₂ ≤ 0.5 ppm
Temperature Control RangeOven, Detector, and Converter up to 400 °C
Power SupplyAC 220 V ±10%, 50 Hz, ≤2500 W
TCD Sensitivity≥5000 mV·mL/mg
FID Detection Limit≤1.0×10⁻¹¹ g/s
System Precision≤1% RSD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
ModelGC-7820 Helium Ionization Gas Chromatograph
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose High-Purity Gas Analysis
Oven Temperature RangeAmbient + 3°C to 450°C
Ramp Rate0.1–40°C/min
Cool-down Time~8 min (450°C → 50°C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature450°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
ModelGC-7820 Methane and Total Hydrocarbons-Specific Gas Chromatograph
Instrument TypeLaboratory Gas Chromatograph
Temperature Control RangeAmbient + 3 °C to 450 °C
Oven Ramp Rate0.1–40 °C/min
Cooling Rate~8 min (450 °C → 50 °C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Max Operating Temperature450 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
Instrument TypeLaboratory Gas Chromatograph
Application FieldEnvironmental Monitoring (Water Quality)
Temperature Control RangeAmbient + 3°C to 450°C
Oven Ramp Rate0.1–40°C/min
Cool-down Time~8 min (450°C → 50°C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature450°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhongkehuifen
OriginBeijing, China
Instrument TypeLaboratory Gas Chromatograph
Application FieldPower Industry (Transformer Oil Dissolved Gas Analysis)
Temperature Control RangeAmbient + 3 °C to 450 °C
Oven Ramp Rate0.1–40 °C/min
Cooling Rate~8 min (450 °C → 50 °C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
DetectorTCD (with automatic bridge current cutoff on carrier gas failure)
ColumnDedicated anti-fouling composite column for transformer oil analysis
Data InterfaceEthernet-enabled, remote control & diagnostics supported
Display5.7-inch LCD, bilingual (English/Chinese), 13-line interface
Self-Diagnostic SystemComprehensive power-on diagnostics, fault code display, power-loss parameter retention, keypad lock, and EMI suppression
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
ModelHFG-961 Online Sulfur Compounds Monitoring System
Temperature Control RangeAmbient + 3 °C to 450 °C
Oven Ramp Rate0.1–40 °C/min
Cool-down Time~8 min (450 °C to 50 °C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Max Operating Temperature450 °C
Injector Pressure Setpoint Range0–970 kPa
Injector Total Flow Setpoint Range0–1200 mL/min
Detection TargetsH₂S, COS, CH₃SH, C₂H₅SH, CH₃SCH₃, CS₂, C₄H₄S (thiophene), C₂H₅SC₂H₅, (CH₃)₂S₂
DetectorFlame Photometric Detector (FPD)
LOD0.01 ppm (as H₂S)
RepeatabilityRSD ≤ 3%
Cycle Time15 min (compound-dependent)
Power Supply220 VAC, 50 Hz, < 4 kW
Operating Environment−10 °C to 50 °C
Output InterfacesRS232 / RS485
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHF-900
Instrument TypeBenchtop Laboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature RangeAmbient + 3°C to 450°C
Oven Ramp Rate0.1–40°C/min
Oven Cool-Down Time~8 min (450°C → 50°C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature450°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhongkehuifen
OriginBeijing, China
ModelGC-7820 Dedicated Gas Analysis System
Instrument TypeLaboratory Gas Chromatograph
Application FieldHigh-Purity Gas Analysis
Temperature Control RangeAmbient + 3 °C to 450 °C
Oven Ramp Rate0.1–40 °C/min
Cooling Rate~8 min (450 °C to 50 °C)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
ConfigurationMultidimensional GC with Dual-10-Port Valves, Dual-6-Port Valves, Four Analytical Columns (including Two Pre-columns), Triple Detectors (Dual TCD + FID)
Data InterfaceDigital Output via Ethernet
SoftwareDedicated Tri-Channel Workstation (Windows 2000/XP/8 Compatible)
Compliance ContextDesigned for GLP-compliant laboratory environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhongkehuifen
OriginBeijing, China
ModelGC-2080 Gas Chromatograph
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose fuel gas analysis
Column Oven Temperature RangeAmbient + 3°C to 450°C
Temperature Ramp Rate0.1–40°C/min
Cooling Rate450°C to 50°C in ~8 min
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 kPa
Injector Maximum Operating Temperature450°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Oven Dimensions260 × 230 × 270 mm (W × D × H)
Weight~50 kg
External Dimensions560 × 540 × 520 mm (W × D × H)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhongkehuifen
OriginBeijing, China
ModelGC-7820 Dedicated Gas Chromatograph for Automotive Gasoline
Instrument TypeLaboratory Gas Chromatograph
Temperature Control RangeAmbient + 3 °C to 450 °C
Oven Ramp Rate0.1–40 °C/min
Cooling Rate~8 min (450 °C to 50 °C)
Carrier Gas Flow Range0–1200 mL/min
Carrier Gas Pressure Range0–970 kPa
Injector Max Temp450 °C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhongkehuifen
OriginShandong, China
ModelGCS-90
Instrument TypeLaboratory Gas Chromatograph
Application FieldPetroleum & Petrochemical Industry
Temperature Control RangeAmbient +5°C to 450°C
Max. Ramp Rate80°C/min
Cooling Rate450°C to 50°C in <5 min
Carrier Gas Flow Range & Control0–1000 mL/min, control resolution 0.01 mL/min
Carrier Gas Pressure Range & Control0–100 psi, control resolution 0.001 psi
Injector Max. Operating Temperature450°C
Injector Pressure Setting Range0–100 psi
Injector Total Flow Setting Range0–1000 mL/min
DetectorFlame Photometric Detector (FPD)
Sulfur LOD (COS)0.02 ppm
Dynamic Range10³
Power Supply220 V, 50 Hz
Ambient Operating Conditions15–35°C, 5–95% RH
Temperature Setpoint Accuracy±0.01°C
Max. Programmable Temperature Steps16 (expandable)
Column ConfigurationMulti-valve, multi-column, center-cutting GC architecture
Data Interface10/100M adaptive Ethernet with embedded TCP/IP stack
Display7-inch resistive touchscreen LCD (bilingual UI: English/Chinese)
SoftwareDedicated sulfur-species workstation supporting up to 253 GC units, Modbus RTU server for DCS integration
Fluidic PathAll-PEEK flow path with passivated surfaces and zero-dead-volume fittings
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZHONGKEHUIFEN
OriginBeijing, China
ModelGC-7900
Carrier Gas Pressure ControlEPC (Electronic Pressure Control)
Column Oven Temperature Range80–120 °C
Analysis Cycle Time30 s (C₁–C₅ hydrocarbons)
Retention Time (C₁)5.5 s
Resolution (k)≥0.9
Hydrogen Pressure0.3 MPa
Air Pressure0.25 MPa
Column Head Pressure0.19 MPa
Sample Gas Pressure0.04 MPa
Sample Gas Flow Rate>600 mL/min
Polarization Voltage180 V DC
Quantitation Loop Volume0.5 mL
Amplification Factor10⁶
Show next