Agilent Technologies
Filter
Showing 31–60 of 567 results
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | LC-1200 |
| Warranty | 6 months |
| Operational Age | 2–3 years (system use), 6–8 years (instrument design life) |
| Application Domain | Chromatography |
| Configuration | Binary Pump (G1312B) + Autosampler (G1329A) + Variable Wavelength UV Detector (G1314B) + Thermostatted Column Compartment (G1316A) |
| Compatible Columns | RRHT and standard HPLC columns (e.g., WondaCract ODS-2, 150 × 4.6 mm, 5 µm) |
| Software | Agilent ChemStation G2170BA |
| Throughput | Up to 2000 samples/day (with ACR configuration) |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1220 Infinity II Analytical-Scale Purification |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.2–10 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1220 Infinity II |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-purpose analytical use in QA/QC and research laboratories |
| Flow Range | 0.2–10 mL/min |
| Injection Volume Range | 0.1–100 µL |
| Width | 370 mm |
| Pump Configuration | Isocratic or Binary Gradient Pump (optional Quaternary configuration) |
| Maximum Number of Temperature-Controlled Zones | 1 (with optional column oven) |
| Maximum Solvent Channels | 4 (with Solvent Selection Valve, SSV) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Column Oven Compatibility | Yes (optional) |
| Detector Options | Variable Wavelength Detector (VWD), Diode Array Detector (DAD), Refractive Index (RID), Fluorescence (FLD), Evaporative Light Scattering (ELSD), Mass Selective Detector (MSD) |
| Software Platforms | OpenLab CDS (ChemStation Edition, EZChrom Edition, or modern OpenLab CDS workstation) |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Sustainability Certification | My Green Lab ACT Label (verified lifecycle environmental impact assessment) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1220 Infinity II |
| Usage Duration | 3–4 years |
| Warranty | 12 months |
| Product Category | Chromatography |
| Configuration | Integrated HPLC System with Isocratic/Gradient Pump, Variable Wavelength Detector (VWD), Column Oven, and Manual or Autosampler Options |
| Software Platform | OpenLAB CDS (EZChrom or ChemStation Edition) |
| Maximum Operating Pressure | 600 bar |
| VWD Data Acquisition Rate | Up to 80 Hz |
| Compliance | Designed to support GLP/GMP workflows, FDA 21 CFR Part 11–ready with audit trail configuration |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 1220 Infinity II |
| Product Category | Chromatography |
| Usage Duration | 6–8 years |
| Warranty | 6 months |
| Pump Pressure Rating | 600 bar |
| Detection | Variable Wavelength Detector (up to 80 Hz) |
| Autosampler Compatibility | Up to 600 bar |
| Column Oven | Temperature-Stabilized |
| Software Options | EZChrom Elite or ChemStation |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 1220, G4294B |
| Configuration | Quaternary Gradient Pump, Autosampler, Column Compartment, Diode Array Detector (DAD) |
| Operational Age | 3 years |
| Warranty | 6 months |
| Category | Liquid Chromatography System |
| Compliance | Fully Refurbished to OEM Specifications |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WX-LC-1220 |
| Service Fee | USD 700–1,400 (excl. parts) |
| Technician Experience | 10+ years |
| Instrument Type | Analytical Instrument |
| Response Time | Within 24 hours |
| Service Scope | Comprehensive HPLC system diagnostics, component-level repair, preventive maintenance, and performance validation |
| Location | Beijing, China |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Agilent 1220 Infinity |
| Instrument Type | Fast HPLC System |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa (400 bar) |
| Sample Tray Capacity | 100 positions (1.5 mL vials) |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 60 °C |
| Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1260 Infinity |
| Price Range | USD 42,000 – 70,000 (FOB) |
| Product Category | Chromatography |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1260 Infinity HPLC |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity II Analytical-Scale Purification |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.05–5 mL/min (with G7112B Pump) |
| Maximum Operating Pressure | 600 bar |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Agilent Technologies |
| Origin Category | Imported |
| Model | 1260 Infinity II Bio-Inert |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | Universal for Biomolecular Analysis |
| Flow Rate Range | 0.2–10 mL/min |
| Maximum Pressure | up to 600 bar |
| Injection Volume Range | 0.1–100 µL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II Bio-SEC |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Biopharmaceutical Characterization |
| Flow Rate Range | Up to 10 mL/min (with G5654A Pump Module) |
| Injection Volume Range | 0.1–100 µL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 1260 Infinity II GPC/SEC |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-Purpose Polymer Characterization |
| Flow Rate Range | Up to 10 mL/min (G7110B Pump Module) |
| Maximum Operating Pressure | 600 bar |
| Injection Volume Range | 0.1–100 µL |
| Temperature Control | Dual-Zone Column Compartment (G7116A/B) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Model | 1260 Infinity II |
| Configuration | Ambient-Temperature Gel Permeation Chromatography System with Optional RI, Viscometry, and Multi-Angle Light Scattering (MALS) Detection |
| Software Platform | Agilent GPC/SEC Software (v4.x or later) |
| Compliance | Designed for GLP/GMP environments |
| Detector Compatibility | Refractive Index (RI), Differential Viscometer, MALS (via optional interface module) |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II High-Temperature GPC |
| Instrument Type | High-Temperature Gel Permeation Chromatography (GPC) / Size Exclusion Chromatography (SEC) System |
| Pump Flow Range | Up to 10 mL/min (with G7110B high-temperature pump module) |
| Pump Pressure Rating | Up to 600 bar |
| Column Oven Temperature Range | Ambient to 220 °C |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Model | 1260 Infinity II (G1312B Pump, G1329B ALS, G1322A Degasser, G1316A Column Oven, G4208B Detector) + 1290 Infinity II G1330B Column Compartment |
| Pressure Range | Up to 600 bar |
| Flow Rate Range | Up to 5 mL/min |
| Detection Options | UV-Vis, Fluorescence, ELSD |
| Sample Injection Precision | ≤ 0.25% RSD |
| Column Compatibility | Conventional, sub-2 µm, and superficially porous particles |
| Software Platform | OpenLab CDS (Compatible with ChemStation Legacy Methods) |
| Warranty | 6 months limited warranty |
| Operational Age | 3–4 years |
| Regulatory Compliance | Fully compatible with FDA 21 CFR Part 11 audit trail requirements when configured with validated OpenLab CDS |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1260, G1312B |
| Price Range | USD 14,000 – 42,000 (FOB) |
| Product Category | Chromatography |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 1260 Infinity II HT GPC |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1260 Infinity II |
| Price Range | USD $13,500 – $40,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Instrument Type | Liquid Chromatograph |
| System Configuration | G4302A Binary Pump, G1379B Degasser, G1316A Column Compartment, G4303A Autosampler (Multisampler), G1315D/C Diode Array Detector (DAD), PC with OpenLab CDS Software |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II Manual Preparative |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 1–50 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 1260 Infinity II |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-purpose QC/QA, R&D, and routine analytical laboratories |
| Flow Rate Range | 0.2–10 mL/min |
| Maximum Pressure | 600 bar |
| Flow Precision | ≤0.07% RSD |
| Injection Volume Range | 0–100 µL |
| Sample Tray Capacity | 100 positions (expandable to 6144 via microtiter plates) |
| Column Oven Temperature Range | 4–80 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 80 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II Multi-Detector GPC/SEC |
| Instrument Type | Ambient-Temperature GPC/SEC System |
| Column Oven & Detector Temperature Range | Independent temperature control per detector, 30–60 °C |
| Maximum Number of Temperature Zones | 2 (G7116A/B Dual-Zone Module) |
| Integrated Column Oven with Autosampler | Single-Zone Configuration |
| Pressure Operating Range | Up to 600 bar |
| Flow Cell Volume (Light Scattering Detector) | 10 µL |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1260 Infinity II MDS |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II Preparative LC/MSD |
| Application Level | Laboratory-Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 1–50 mL/min |
| Maximum Operating Pressure | 20–420 bar |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II Preparative |
| Application Level | Laboratory-Scale Purification |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–50 mL/min |
| Flow Accuracy | ≤0.3% RSD |
| Flow Precision | ≤0.3% RSD |
| Maximum Pressure | 420 bar |
| Wavelength Range | 190–700 nm (0.1 nm resolution) |
| Baseline Noise | 2.5 µAU at 254 nm, 1 s time constant |
| Data Acquisition Rate | 120 Hz |
| Injection Volume Range | 0.1–5000 µL |
| Fraction Capacity | Up to 648 tubes (with optional fraction collector upgrade) |
| System Dead Volume | Minimized via integrated delay sensor calibration |
| Solvent Channels | 2 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (W × D × H) | 941 × 462 × 640 mm |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Configuration Options | 1260 Dual-Gradient High-Pressure Pump / 1260 Infinity II Quaternary Low-Pressure Pump |
| Maximum Pressure | 600 bar |
| Flow Rate Range | 0.05–5 mL/min at 600 bar |
| Injection Volume | 0.1–100 µL (0.1 µL increments) |
| Column Oven Temperature Range | –10 °C to 80 °C (up to 100 °C with optional 1290 Infinity Column Compartment) |
| Temperature Stability | < ±0.15 °C |
| UV Detector Data Acquisition Rate | 80 Hz (DAD, 60 mm flow cell) |
| Baseline Noise | ≤ 0.6 µAU/cm |
| Detection Options | UV/Vis DAD, Fluorescence, ELSD |
| Compliance Features | EMF (Early Maintenance Feedback), RFID-enabled consumables tracking (lamp, flow cell), Data Recovery Card (DRC), GLP/GMP-ready audit trail support via OpenLab CDS |
| Warranty | 12 months |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | LC-1260 |
| Maximum Pressure | 600 bar |
| Pump Delay Volume | as low as 120 µL |
| Flow Rate Range (Quaternary Pump) | 0.001–10 mL/min |
| DAD Data Acquisition Rate | up to 80 Hz |
| UV Noise Level | < ±0.6 mAU/cm (with 60 mm flow cell) |
| Typical Flow Precision | <0.15% RSD |
| Usage Age | 6–8 years |
| Warranty | 1 year post-installation |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 1260 Infinity II |
| Instrument Category | Liquid Chromatography (HPLC) |
| Operational Age | 6–8 years |
| Warranty | 12 months |
| Compliance | Fully refurbished to meet Agilent’s certified pre-owned standards |
| Software | OpenLAB CDS (ChemStation or EZChrom compatible) |
| Configuration | Quaternary pump, DAD or VWD detector, thermostatted autosampler, column compartment |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | 1260 Infinity III Amino Acid Analysis System |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-purpose amino acid analysis |
| Flow Rate Range | Up to 10 mL/min (G7111B pump module) |
| Maximum Operating Pressure | 600 bar |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | 5 °C above ambient to 80 °C |
| Solvent Reservoir Capacity | 4 channels |
| Power Supply | 100–240 VAC |
| Dimensions (W × D × H) | 396 × 468 × 560 mm |
| Column ID Reader | Optional |
| Smart System Emulation | Not supported |
| ACT Certification | My Green Lab ACT certified for environmental accountability, consistency, and transparency |