Daxluot
Filter
Showing all 18 results
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Daxluot-16S |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 22–2200 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume per Channel | 5–100 mL |
| Parallel Channels | 16 |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Auto-compensated under variable load |
| Data Storage Capacity | 20 user-defined protocols |
| Display | 7-inch TFT capacitive touchscreen |
| Safety Protections | Overtemperature, overcurrent, overtime, and fault alarm |
| Input Power | AC 220 V ±5%, 50 Hz (110 V optional) |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Daxluot-24S |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 25–2500 W (adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking) |
| Temperature Range | −5 to 100 °C |
| Sample Volume per Channel | 0.1–5 mL |
| Number of Simultaneous Samples | 24 |
| Display | 7-inch TFT Touchscreen |
| Data Storage | 20 Preset Protocols |
| Amplitude Control | Auto-compensated |
| Probe Material | Titanium Alloy (Grade 5) |
| Safety Features | Overtemperature, Overpower, and Overtime Protection |
| Cooling Interface | Integrated Low-Temperature Circulating Rack (−5 to 100 °C) |
| Communication Option | RS-232/USB (optional) |
| Footswitch Support | Optional |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-4SKII |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 18–1800 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume per Channel | 5–100 mL |
| Number of Simultaneous Samples | 4 |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Auto-compensated under variable load |
| Data Storage Capacity | 20 user-defined protocols |
| Display | 7-inch TFT capacitive touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz (110 V optional) |
| Safety Protections | Overtemperature, over-power, and overtime cutoffs |
| Communication Interface | RS-232 or USB (optional) |
| Footswitch Support | Optional |
| Cryogenic Compatibility | Integrated Peltier-cooled sample rack with external chiller port |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-5CTL |
| Ultrasonic Power | 1800 W (continuously adjustable) |
| Frequency Range | 20–25 kHz |
| Heating Power | 1000 W |
| Temperature Range | −10 to 100 °C |
| Reactor Volume | 5000 mL |
| Stirring Power | 60 W |
| Stirring Speed | 10–1200 rpm |
| Ultrasonic Duty Cycle | 0.1–99.9% |
| Cooling Capacity | 500 W |
| Cooling Temperature Range | −5 °C to ambient |
| Power Supply | 220 V AC |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-8S |
| Ultrasonic Power | 20–2000 W (adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking) |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume per Channel | 5–100 mL |
| Number of Simultaneous Samples | 8 |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Automatic Load-Compensated |
| Data Storage | 20 Preset Protocols |
| Display | 7-inch TFT Touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz |
| Safety Protections | Overtemperature, Overpower, Overtime |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | DLM-0503 |
| Cooling Method | Air-Cooled |
| Temperature Range | −5 °C to 100 °C |
| Temperature Stability | ±0.5 °C |
| Refrigeration Capacity | 400 W |
| Circulation Pressure | 0.7 bar |
| Flow Rate | 8 L/min |
| Reservoir Volume | 3.5 L |
| Operating Mode | Continuous |
| Display Resolution | 0.1 °C |
| Power Supply | 220 V / 50 Hz |
| Housing Material | ABS Molded Enclosure |
| Pump Type | Sealed, Low-Heat, Low-Noise Circulation Pump |
| Safety Features | Dry-run protection, Overtemperature alarm, Overcurrent & Overheat compressor protection, Dual-audio/visual alarm system |
| Interface Fittings | 304 Stainless Steel Bayonet Couplings |
| Dimensions (W×D×H) | 440 × 300 × 510 mm |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | DLM-1003 |
| Type | Integrated Circulating Chiller |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 100 °C |
| Temperature Stability | ±0.5 °C |
| Refrigeration Capacity | 800 W |
| Circulation Pressure | 0.7 bar |
| Flow Rate | 8 L/min |
| Reservoir Volume | 3.5 L |
| Operating Mode | Continuous |
| Display Resolution | 0.1 °C |
| Power Supply | 220 V / 50 Hz |
| Housing Material | ABS Molded Enclosure |
| Pump Type | Hermetic, Low-Heat Circulation Pump |
| Safety Features | Overtemperature Alarm, Low-Liquid-Level Protection, Compressor Overheat & Overcurrent Protection, Dual-Audio/Visual Alert |
| Interface | 304 Stainless Steel Bayonet Fittings |
| Dimensions (W×D×H) | 440 × 300 × 510 mm |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | DLM-2003 |
| Cooling Method | Air-Cooled |
| Temperature Range | −20 to 100 °C |
| Temperature Stability | ±0.5 °C |
| Refrigeration Capacity | 1200 W |
| Circulation Pressure | 0.7 bar |
| Flow Rate | 8 L/min |
| Reservoir Volume | 3.5 L |
| Operation Mode | Continuous |
| Display Resolution | 0.1 °C |
| Power Supply | 220 V / 50 Hz |
| Housing Material | ABS Molded Enclosure |
| Pump Type | Hermetically Sealed, Low-Heat, Low-Noise Motor |
| Safety Features | Overtemperature Alarm, Low-Liquid-Level Protection, Compressor Overheat & Overcurrent Protection, Power-Fail Memory |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | DLM1503 |
| Cooling Method | Air-Cooled |
| Temperature Range | −15 °C to 100 °C |
| Refrigeration Capacity | 1000 W |
| Temperature Stability | ±0.5 °C |
| Circulation Pressure | 0.7 bar |
| Flow Rate | 8 L/min |
| Reservoir Volume | 3.5 L |
| Operation Mode | Continuous |
| Display Resolution | 0.1 °C |
| Power Supply | 220 V / 50 Hz |
| Dimensions (W×D×H) | 440 × 300 × 510 mm |
| Housing Material | ABS Molded Enclosure |
| Pump Type | Sealed, Low-Heat, Low-Noise Circulation Pump |
| Safety Features | Overtemperature Alarm, Low-Liquid-Level Protection, Compressor Overheat & Overcurrent Protection, Dual-Mode (Heating/Cooling) Independent Control |
| Fluid Interface | 304 Stainless Steel Bayonet Fittings |
| Drainage | Integrated Hidden Drain Valve |
| Accessories | Silicone Circulation Tubing, Thermal Insulation Sleeve, Drain Spout |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | DLT-0506 |
| Temperature Range | −5 to 100 °C |
| Temperature Stability | ±0.05 °C |
| Bath Volume | 6 L |
| Circulation Flow Rate | 10 L/min |
| Tank Opening | 180 × 140 mm |
| Internal Dimensions | 270 × 200 × 130 mm |
| External Dimensions | 440 × 300 × 750 mm |
| Power Supply | 220 V / 50 Hz |
| Cooling/Heating Type | Dual-mode (Refrigeration & Heating) |
| Circulation Mode | Internal & External |
| Bath Material | 304 Stainless Steel |
| Safety Features | Dry-run protection, over-temperature alarm, compressor overheat & overcurrent protection, auto power-off on failure |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DLT-1006 |
| Instrument Type | Constant-Temperature Bath |
| Circulation Mode | Internal & External |
| Temperature Control | Refrigeration & Heating |
| Bath Volume | 6 L |
| Temperature Range | −10 °C to 100 °C |
| Temperature Stability | ±0.05 °C |
| Flow Rate | 10 L/min |
| Bath Opening | 180 × 140 mm |
| Bath Interior Dimensions | 270 × 200 × 130 mm |
| External Dimensions | 440 × 300 × 750 mm |
| Power Supply | 220 V / 50 Hz |
| Construction Material | 304 Stainless Steel Bath & Top Plate |
| Cooling System | Hermetically Sealed Air-Cooled Compressor Unit |
| Safety Features | Dry-run protection, over-temperature alarm, over-current & over-heat compressor protection, audible/visual alerts |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | DLT-2006 |
| Type | Circulating Constant-Temperature Bath |
| Temperature Range | −20 °C to 100 °C |
| Temperature Stability | ±0.05 °C |
| Bath Volume | 6 L |
| Circulation Flow Rate | 10 L/min |
| Tank Opening | 180 mm × 140 mm |
| Internal Dimensions | 270 mm × 200 mm × 130 mm |
| External Dimensions | 440 mm × 300 mm × 750 mm |
| Power Supply | 220 V / 50 Hz |
| Cooling/Heating Mode | Dual-mode (Compressor-based refrigeration + electric heating) |
| Circulation Type | Internal & external circulation |
| Construction Material | 304 stainless steel tank and top plate |
| Safety Features | Dry-run protection, over-temperature alarm, compressor overheat/overcurrent protection, audible & visual alerts |
| Brand | Daxluot |
|---|---|
| Model | DW-86L158 |
| Type | Upright |
| Effective Volume | 158 L |
| Interior Dimensions (W×D×H) | 380 × 410 × 1020 mm |
| Exterior Dimensions (W×D×H) | 620 × 660 × 1795 mm |
| Power Supply | 220 V AC, 50 Hz |
| Rated Power Input | 500 W |
| Protection Class | I/B |
| Temperature Range | –40 °C to –86 °C (adjustable) |
| Refrigeration System | Single-stage compression with eco-friendly mixed refrigerant |
| Insulation | High-density polyurethane foam (≥120 mm thickness) |
| Door Configuration | Dual-door with dual magnetic gaskets |
| Control System | Digital electronic temperature controller with PID algorithm |
| Safety Features | Audible/visual alarms for high temperature, door ajar, power failure, and sensor fault |
| Evaporator | Copper tube evaporator |
| Mobility | Four swivel casters with locking brakes |
| Environmental Compliance | CFC-free refrigerant (R404A/R507 blend) and HCFC-free blowing agent |
| Brand | Daxluot |
|---|---|
| Model | Dxluot-4SKI |
| Origin | Shanghai, China |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 12–1200 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Sample Volume per Channel | 1–10 mL |
| Number of Simultaneous Samples | 4 |
| Temperature Control Range | −5 to 100 °C |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Automatic load-compensated |
| Programmable Parameters | 20 user-defined protocols |
| Ultrasound On/Off Time | 0.1–99.9 s (adjustable) |
| Total Cycle Duration | 0.1 s – 99 h 59 min 59 s |
| Safety Protections | Overtemperature, Overpower, Overtime |
| Display | 7-inch TFT capacitive touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz (110 V optional) |
| Communication Interface | RS-232 or USB (optional) |
| Footswitch Support | Optional |
| Data Logging | Timestamped protocol execution history |
| Cooling Integration | Integrated Peltier-assisted cold block with recirculating thermal management |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | HJ911-8P |
| Ultrasonic Power | 4000 W (2 × 2000 W channels) |
| Frequency | 20 kHz ±1 kHz |
| Temperature Range | Ambient to 90 °C |
| Sample Capacity | 300 mL × 8 channels |
| Transducer Diameter | 12 mm × 8 |
| Control Interface | 7-inch color touchscreen + PLC-based dual-control system |
| Operation Modes | Pulsed or continuous ultrasonication |
| Safety Features | Overtemperature protection, fault alarm, password-protected program access, integrated acoustic shielding |
| Application Scope | Laboratory-scale and pilot-scale extraction, cell disruption, nano-dispersion, emulsification, and cleaning |
| Brand | Daxluot |
|---|---|
| Model | UVI |
| Type | Benchtop UV-Blue Transilluminator & Gel Cutter |
| Wavelength | 470 nm (Blue LED) |
| Filter Dimensions | 160 × 100 mm |
| Illumination | Dual-Sided LED Matrix |
| Input Power | DC 24 V, 1 A |
| Cutting Area | 160 × 100 mm |
| Overall Dimensions | 220 × 210 × 50 mm |
| Weight | 1.5 kg |
| Safety | Integrated Transparent UV-Blocking Acrylic Shield |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-MC |
| Detection Time (Brightfield) | <3 sec |
| Cell Concentration Range | 7×10²–2.5×10⁷ cells/mL |
| Adjustable Sample Height | 50 µm (5 µL), 100 µm (10 µL), 400 µm (40 µL) |
| Cell Diameter Range | 4–400 µm |
| Imaging Resolution | 5 MP brightfield |
| Excitation/Filter | AO 530 nm, PI 620 nm |
| Illumination | LED-based brightfield |
| Sample Stage Material | Hydrophilic quartz glass |
| Focus | Auto- and manual-focus modes |
| Power Supply | 12 V DC |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | DLT-8006N |
| Bath Volume | 5 L |
| Temperature Range | −80 °C to Ambient |
| Temperature Stability | ±0.05 °C |
| Control Resolution | 0.01 °C (selectable) |
| Circulation Flow Rate | 8 L/min |
| Refrigeration Type | Cascade (Dual-Compressor) |
| Cooling Capacity | 2.2 kW (Stage 1), 3.7 kW (Stage 2) |
| Heating Power | 1.5 kW |
| Pump Type | Hermetic, Low-Heat, Low-Noise Circulation Motor |
| Construction | 304 Stainless Steel Inner Tank & Deck |
| External Circulation | Yes |
| Internal Circulation | Yes |
| Safety Features | Dry-run Protection, Over-Temperature Alarm, Compressor Overheat/Overcurrent Protection, Power-Fail Memory |
| Optional | Integrated Magnetic Stirrer, Flask Holder Kit |