| Brand | EDC |
|---|---|
| Origin | USA |
| Model | Air Aide AA-3500 |
| Measurement Principle | Nephelometric Light Scattering (90° detection geometry) |
| Safety Rating | Non-explosion-proof |
| Measurement Ranges | 0.001–20.0 mg/m³ and 0.01–200 mg/m³ (user-selectable dual range) |
| Resolution | 0.001 mg/m³ |
| Accuracy (2σ stability) | ±0.004 mg/m³ |
| Temperature Drift (2σ) | ±0.0025 mg/m³/°C |
| Analog Output | 0–2 VDC |
| Certifications | CE, ETL |
| Sampling Inlet Options | PM₁₀, PM₂.₅, PM₁.₀, and Respirable Dust (4.5 µm D₅₀ cutoff) |
| Brand | EDC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PC-2HX |
| Instrument Type | Aerosol Size Distribution and Mass Concentration Analyzer |
| Measurement Principle | Inertial Impaction with QCM Gravimetric Detection |
| Size Range | 0.1–25 µm (10-stage cascade impactor configuration) |
| Flow Rate | 2.0 L/min (PC-2HX variant) |
| Mass Sensitivity | 1 ng/Hz |
| Detection Limit | ~5 µg/m³ (typical) |
| Minimum Detectable Particle Diameter | 100 nm |
| Output | Real-time size-resolved mass concentration (µg/m³ per stage), PM₁ / PM₂.₅ / PM₁₀ equivalent calculation, timestamped histogram export |
| Interface | RS-232 / USB to PC |
| Sample Substrate | Removable QCM crystals or aluminum collection plates for SEM/EDS analysis |
| Brand | EDC |
|---|---|
| Origin | USA |
| Model | DPM-4000 |
| Instrument Type | Aerosol Detector |
| Measurement Range | 1–20,000 µg/m³ |
| Resolution | ±2 µg/m³ |
| Accuracy | ±10% |
| Particle Size Range | <1–10 µm |
| Sampling Flow Rate | 1.0–3.3 L/min (recommended 1.7 L/min) |
| Display | 4-line × 20-character LCD (units: µg/m³, mg/m³, TWA, STEL, min/max) |
| Data Storage | 21,500 points (>5 years retention) |
| Logging Interval | 1 sec to 21 weeks |
| Alarm | 90 dB at 3 ft |
| Operating Temp | 0–50 °C |
| Storage Temp | −20–70 °C |
| Humidity | ≤95% RH non-condensing |
| Power | Rechargeable battery (>8 h runtime |
| Dimensions | 140 × 83 × 70 mm |
| Weight | 1.0 kg |
| Compliance | NIOSH 5040 compatible, NIST-traceable calibration support, OSHA-compliant exposure assessment |
| Brand | EDC |
|---|---|
| Origin | USA |
| Model | EPAM-5000 |
| Measurement Principle | Integrated Optical Scattering & Gravimetric Filtration |
| Safety Rating | Non-Explosive |
| Measurement Range | 0.01–200.0 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±0.003 mg/m³ |
| Relative Error | ±0.003 mg/m³ |
| Particle Size Range | 0.1–100 µm |
| Flow Rate | 1.0–5.0 L/min |
| Filter Diameter | 47 mm FRM-compliant |
| Alarm Output | 90 dB at 3 ft |
| Analog Output | 0–2 VDC |
| Data Logging Interval | 1 sec to 30 min |
| Memory Capacity | 21,600 data points |
| Internal Clock Backup | >5 years |
| Operating Temperature | –10 °C to +50 °C |
| Storage Temperature | –20 °C to +70 °C |
| Humidity Range | ≤95% RH non-condensing |
| Dimensions (H×W×D) | 35.6 × 15.2 × 25.4 cm |
| Weight | 5.4 kg |
| Power | Rechargeable battery (24 h runtime) or AC adapter (22 h recharge time) |
| Brand | EDC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GB-2000 |
| Pricing | Available Upon Request |
| Brand | EDC |
|---|---|
| Origin | USA |
| Model | HD-1100 |
| Measurement Range | 0.01–20 / 200 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ±10% |
| Display | 3.5" LCD |
| Units | mg/m³ |
| Calibration Standard | NIOSH Method 0600 |
| Particle Size Range | 0.01–50 µm |
| Power Supply | 6 VDC NiMH Rechargeable Battery |
| Operating Time | >8 hours |
| Charging Time | 10–12 hours |
| Output Signal | 0–2 V analog |
| Max Operating Humidity | 95% non-condensing |
| Dimensions | 22.9 × 7.6 × 3.8 cm |
| Weight | 0.91 kg |
| Brand | EDC |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HIM-6000 |
| Pricing | Available Upon Request |
| Measured Parameters | TSP, PM-10, PM-2.5, PM-1.0, PM-4.0 |
| Optional Sensors | NO₂, SO₂, O₃, CO, CO₂, O₂, Hydrocarbons, UV/IR Radiation, Barometric Pressure (hPa), Noise (dB(A)), ELF Magnetic Field (µT), Rainfall (mm), Biochemical Agent Detectors |
| Brand | EDC |
|---|---|
| Origin | USA |
| Model | HIM6000 |
| Sensor Capacity | Up to 12 simultaneous channels (PM, gas, meteorological) |
| Compliance | EPA Reference/Equivalent Methods, EU Directive 2008/50/EC |
| Power Options | Rechargeable 12V NiMH battery, solar-compatible |
| Communication | Wi-Fi 2.4/5 GHz, LTE/GSM, 900 MHz RF, Ethernet |
| Data Storage | Internal 1-year buffered logging |
| Deployment | Portable tripod-mountable, field-rugged enclosure |
| PM Measurement | Simultaneous PM₁.₀, PM₂.₅, PM₁₀, and/or TSP (dual-channel configurable) |
| Gas Detection Range | ppb–% vol (application-specific sensor calibration per OSHA, NIOSH, or EPA protocols) |
| Environmental Operating Range | −20 °C to +60 °C |
| Enclosure Rating | IP65 |
| Brand | EDC |
|---|---|
| Origin | USA |
| Model | VDM-7500 |
| Measurement Principle | Video Imaging + Gravimetric Reference Correlation |
| Safety Rating | Non-Explosive (Non-Intrinsically Safe) |
| Measurement Range | 0.01–200 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% (vs. NIOSH-approved gravimetric filter method) |
| Particle Size Detection Range | 0.1–100 µm |
| Flow Rate | 1.0–3.3 L/min |
| Data Logging Capacity | 21,500 points |
| Sampling Interval | 1 s to 10 min |
| Operating Temperature | 0–50 °C |
| Battery Life | >8 h (NiMH rechargeable) |
| Dimensions (Main Unit) | 13.7 × 8.4 × 6.8 cm |
| Weight | 0.68 kg |